Study of water accumulation dynamics in the channels of an open-cathode fuel cell through electro-thermal characterisation and droplet visualisation

被引:38
|
作者
Obeisun, Oluwamayowa A. [1 ]
Meyer, Quentin [1 ]
Engebretsen, Erik [1 ]
Finegan, Donal P. [1 ]
Robinson, James B. [1 ]
Hinds, Gareth [2 ]
Shearing, Paul R. [1 ]
Brett, Daniel J. L. [1 ]
机构
[1] UCL, Dept Chem Engn, Electrochem Innovat Lab, London WC1E 7JE, England
[2] Natl Phys Lab, Teddington TW11 0LW, Middx, England
基金
英国工程与自然科学研究理事会;
关键词
Open-cathode fuel cell; Fuel cell orientation; Temperature mapping; Electrochemical impedance spectroscopy; Fuel cell gravimetric analysis; Water management; PRINTED-CIRCUIT BOARD; LIQUID WATER; TEMPERATURE DISTRIBUTION; RELATIVE-HUMIDITY; DIFFUSION LAYERS; FLOW CHANNELS; 2-PHASE FLOW; PEMFC; EXCHANGE; PERFORMANCE;
D O I
10.1016/j.ijhydene.2015.07.066
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Open-cathode polymer electrolyte fuel cells have the advantage of simplified construction and the potential for cost reduction. However, effective water and temperature management calls for a different approach to conventional fuel cells. Improved understanding of the link between current density, temperature, water formation and hydration of the membrane is required to optimise cell design. This work uses thermal imaging, optical visualisation, gravimetric analysis and electrochemical impedance spectroscopy to study the links between these factors and also examines the effect of cell orientation on performance. The results reinforce the importance of cell temperature for water management, which is a function of current density. Regions of the cell with higher temperature avoid flooding by promoting vapour phase water; however, this can lead to higher membrane resistance due to dehydration. The results reveal that transition in the water balance regime from continuous hydration and flooding to drying with increasing current density occurs between 34 degrees C-40 degrees C (at 250 mA cm(-2)) and water generation is balanced with evaporation at similar to 50 degrees C (550 mA cm(-2)). Finally, fuel cell orientation affects performance after extended operation due to the effect of water accumulation and evaporation, with the cathode in a 'flat upwards' orientation found to be most resistant to flooding and cathode in a flat downwards orientation the most likely to flood. Copyright (C) 2015, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:16786 / 16796
页数:11
相关论文
共 44 条
  • [21] An experimental study for optimizing the energy efficiency of a proton exchange membrane fuel cell with an open-cathode
    Le, Phuong-Long
    Singh, Bhupendra
    Chen, Yong-Song
    Arpornwichanop, Amornchai
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (52) : 26507 - 26517
  • [22] Numerical Investigation of Water and Temperature Distributions for Open-Cathode Polymer Electrolyte Fuel Cell Stack With Edge Cooling
    Sasmito, Agus P.
    Shamim, Tariq
    Birgersson, Erik
    Mujumdar, Arun S.
    JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2013, 10 (06):
  • [23] Computational study of forced air-convection in open-cathode polymer electrolyte fuel cell stacks
    Sasmito, A. P.
    Lum, K. W.
    Birgersson, E.
    Mujumdar, A. S.
    JOURNAL OF POWER SOURCES, 2010, 195 (17) : 5550 - 5563
  • [24] NUMERICAL INVESTIGATION OF WATER AND TEMPERATURE DISTRIBUTIONS FOR OPEN-CATHODE POLYMER ELECTROLYTE FUEL CELL STACK WITH EDGE COOLING
    Sasmito, Agus Pulung
    Shamim, Tariq
    Birgersson, Erik
    Mujumdar, Arun Sadashiv
    PROCEEDINGS OF THE ASME 11TH FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY CONFERENCE, 2013, 2014,
  • [25] The Hydro-electro-thermal Performance of Air-cooled, Open-cathode Polymer Electrolyte Fuel Cells: Combined Localised Current Density, Temperature and Water Mapping
    Meyer, Quentin
    Ashton, Sean
    Jervis, Rhodri
    Finegan, Donal P.
    Boillat, Pierre
    Cochet, Magali
    Curnick, Oliver
    Reisch, Tobias
    Adcock, Paul
    Shearing, Paul R.
    Brett, Dan J. L.
    ELECTROCHIMICA ACTA, 2015, 180 : 307 - 315
  • [26] Hydrogen preheating through waste heat recovery of an open-cathode PEM fuel cell leading to power output improvement
    Mohamed, W. A. N. W.
    Kamil, M. Haziq M.
    ENERGY CONVERSION AND MANAGEMENT, 2016, 124 : 543 - 555
  • [27] Dual-threshold control architecture for improved thermal and power management in open-cathode direct methanol fuel cell
    Alyousef, Zuhair
    Crisalle, Oscar D.
    ENERGY CONVERSION AND MANAGEMENT-X, 2024, 23
  • [28] Performance and thermal optimization of different length-width ratio for air-cooled open-cathode fuel cell
    Zhao, Chen
    Xing, Shuang
    Liu, Wei
    Chen, Ming
    Wang, Haijiang
    RENEWABLE ENERGY, 2021, 178 : 1250 - 1260
  • [29] Dynamics of Emerging Water Droplet Subjected to Sidewall with Different Wettabilities in a Fuel Cell Cathode Channel
    Zhu, X.
    Sui, P. C.
    Djilali, N.
    Liao, Q.
    FUEL CELLS, 2011, 11 (03) : 404 - 412
  • [30] Experimental study of hydrogen purge effects on performance and efficiency of an open-cathode Proton Exchange Membrane fuel cell system
    Strahl, Stephan
    Husar, Attila
    Riera, Jordi
    JOURNAL OF POWER SOURCES, 2014, 248 : 474 - 482