Evaluation of the ACR MRI phantom for quality assurance tests of 1.5 T MRI scanners in Estonian hospitals

被引:4
|
作者
Kaljuste, Doris [1 ]
Nigul, Mait [2 ]
机构
[1] Tallinn Univ Technol, Dept Biomed Engn, EE-19086 Tallinn, Estonia
[2] East Tallinn Cent Hosp, EE-10138 Tallinn, Estonia
关键词
magnetic resonance imaging; ACR MRI phantom; quality assurance; MRI image quality;
D O I
10.3176/proc.2014.3.06
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Since its discovery, magnetic resonance imaging (MRI) has been one of the main methods of imaging in radiology. So far, there are not many national or international guidelines for MRI quality assurance compared to imaging methods that are using ionizing radiation. American College of Radiology (ACR) has an accreditation program that includes a standardized image quality measurement protocol and a phantom. Seven important assessments of MRI image quality are included with acceptance criteria. The aim of this study was to determine whether using the ACR MRI phantom would be a suitable quality assurance method for MRI systems in Estonia. In order to determine if the ACR MRI phantom would be a suitable quality assurance method for MRI systems in Estonia, six MRI scanners were tested using the ACR MRI accreditation program phantom and method. Information about the image quality was obtained and 33% of the MRI scanners passed all seven assessments. In conclusion, the ACR MRI phantom is a suitable test body for some of the MRI scanners in Estonia and should be considered to be used for regular quality testing. Due to the fact that in some cases the ACR MRI phantom did not fit into the head coil, using the ACR MRI phantom cannot be nationally required and other quality assurance phantoms should also be assessed. Adding signal-to-noise ratio assessment to seven assessment criteria, provided by ACR quality assurance manual, and developing an automated ACR quality assurance procedure would make quality assurance with ACR MRI phantom more beneficial.
引用
收藏
页码:240 / 246
页数:7
相关论文
共 50 条
  • [1] Quality assurance of clinical MRI scanners using ACR MRI phantom: Preliminary results
    Chen, CC
    Wan, YL
    Wai, YY
    Liu, HL
    JOURNAL OF DIGITAL IMAGING, 2004, 17 (04) : 279 - 284
  • [2] Quality Assurance of Clinical MRI Scanners Using ACR MRI Phantom: Preliminary Results
    Chien-Chuan Chen
    Yung-Liang Wan
    Yau-Yau Wai
    Ho-Ling Liu
    Journal of Digital Imaging, 2004, 17 : 279 - 284
  • [3] AUTOMATED LOW CONTRAST DETECTION FOR ACR MRI PHANTOM QUALITY ASSURANCE
    Madamesila, Joseph
    Golestani, Ali
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S136 - S137
  • [4] An open source automatic quality assurance (OSAQA) tool for the ACR MRI phantom
    Jidi Sun
    Michael Barnes
    Jason Dowling
    Fred Menk
    Peter Stanwell
    Peter B. Greer
    Australasian Physical & Engineering Sciences in Medicine, 2015, 38 : 39 - 46
  • [5] An open source automatic quality assurance (OSAQA) tool for the ACR MRI phantom
    Sun, Jidi
    Barnes, Michael
    Dowling, Jason
    Menk, Fred
    Stanwell, Peter
    Greer, Peter B.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (01) : 39 - 46
  • [6] MRI quality assurance using the ACR phantom in a multi-unit imaging center
    Ihalainen, Toni M.
    Lonnroth, Nadja T.
    Peltonen, Juha I.
    Uusi-Simola, Jouni K.
    Timonen, Marjut H.
    Kuusela, Linda J.
    Savolainen, Sauli E.
    Sipila, Outi E.
    ACTA ONCOLOGICA, 2011, 50 (06) : 966 - 972
  • [7] Quality assurance for diffusion tensor imaging using an ACR phantom: Comparative analysis with 6, 15, and 32 directions at 1.5T and 3.0T MRI systems
    Lee, Jung-Hoon
    Kim, Sang-Young
    Lee, Do-Wan
    Jung, Jin-Young
    Song, Kyu-Ho
    Choe, Bo-Young
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (01) : 103 - 110
  • [8] Quality assurance for diffusion tensor imaging using an ACR phantom: Comparative analysis with 6, 15, and 32 directions at 1.5T and 3.0T MRI systems
    Jung-Hoon Lee
    Sang-Young Kim
    Do-Wan Lee
    Jin-Young Jung
    Kyu-Ho Song
    Bo-Young Choe
    Journal of the Korean Physical Society, 2014, 65 : 103 - 110
  • [9] Optimizing Acr MRI Phantom Quality Control: A Pilot Implementation of on-Scanner QC Analysis, Report Generation and Failure Alert Software on MRI Scanners
    Wu, M. J.
    Tan, X.
    Peng, B.
    Pomeroy, M. J.
    Chaudhary, P.
    Lin, T.
    Jambawalikar, S. R.
    MEDICAL PHYSICS, 2024, 51 (09) : 6558 - 6558
  • [10] Compressed sense accelerated MRI simulation: image quality assessment using an ACR MRI phantom
    Wong, O. L.
    Yuan, J.
    Zhou, Y.
    Cheung, K. Y.
    Yu, S. K.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S993 - S994