Electrochemical detection of DNA damage induced by clenbuterol at a reduced graphene oxide-Nafion modified glassy carbon electrode

被引:20
|
作者
Lin, Xiaoyun [1 ]
Ni, Yongnian [1 ,2 ]
Pei, Xueying [1 ]
Kokot, Serge [3 ]
机构
[1] Nanchang Univ, Sch Chem, Nanchang 330031, Jiangxi, Peoples R China
[2] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Jiangxi, Peoples R China
[3] Queensland Univ Technol, Sch Chem Phys & Mech Engn, Brisbane, Qld 4001, Australia
基金
中国国家自然科学基金;
关键词
QUANTITATIVE MEASUREMENT; METHYLENE-BLUE; IN-SITU; SENSOR; NANOPARTICLES; REDUCTION; TOXICITY; CATALYST; ACID; FILM;
D O I
10.1039/c6ay03022j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical biosensor capable of direct detection of DNA damage induced by clenbuterol (CLB) has been developed. A glassy carbon electrode (GCE) was modified using reduced graphene oxide-Nafion and dsDNA to produce a dsDNA/RGO-Nafion/GCE sensor. The modified electrode was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV), and the results at each stage of the electrode construction were interpreted. They indicated that the electrochemical oxidation peak currents of guanine and adenine at the electrode (dsDNA/RGO-Nafion/GCE) significantly increased as compared with those at the untreated electrode (dsDNA/GCE). Based on this, the sensor was used to measure the change of the oxidation peak currents for guanine and adenine between the intact and damaged dsDNA in the sensor films, and the DNA damage was successfully detected. Furthermore, the plot of peak current decline for the guanine and adenine versus the concentration of CLB was linear in the range of 5.0 x 10(-7) to 4.0 x 10(-6) mol L-1, with a limit of detection (LOD) of 3.2 x 10(-7) mol L-1, which provided a good method to determine CLB indirectly.
引用
收藏
页码:1105 / 1111
页数:7
相关论文
共 50 条
  • [31] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Fangyuan Zhao
    Fei Wang
    Weining Zhao
    Jing Zhou
    Yang Liu
    Lina Zou
    Baoxian Ye
    Microchimica Acta, 2011, 174 : 383 - 390
  • [32] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Zhao, Fangyuan
    Wang, Fei
    Zhao, Weining
    Zhou, Jing
    Liu, Yang
    Zou, Lina
    Ye, Baoxian
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 383 - 390
  • [33] Modified glassy carbon electrode based on myoglobin and reduced graphene oxide for hydrogen peroxide detection
    Szoke, A.
    Turdean, G.
    Muresan, L.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2017, 49 : 147 - 154
  • [34] Electro-reduced graphene oxide film modified glassy carbon electrode as an electrochemical sensor for sibutramine
    Teradal, Nagappa L.
    Narayan, Prashanth S.
    Jaladappagari, Seetharamappa
    ANALYTICAL METHODS, 2013, 5 (24) : 7090 - 7095
  • [35] Electrochemical studies of NADH oxidation on chemically reduced graphene oxide nanosheets modified glassy carbon electrode
    Immanuel, Susan
    Sivasubramanian, R.
    MATERIALS CHEMISTRY AND PHYSICS, 2020, 249
  • [36] Electrochemical Behavior and Voltammetric Determination of Curcumin at Electrochemically Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Ouyang, Xiaoyan
    Ma, Jing
    Li, Lingzhi
    Zhang, Yanmin
    ELECTROANALYSIS, 2016, 28 (04) : 749 - 756
  • [37] Electrochemical detection of ciprofloxacin based on graphene modified glassy carbon electrode
    Xie, A. -J.
    Chen, Y.
    Luo, S. -P.
    Tao, Y. -W.
    Jin, Y. -S.
    Li, W. -W.
    MATERIALS TECHNOLOGY, 2015, 30 (06) : 362 - 367
  • [38] An Electrochemical Sensor Based on Reduced Graphene Oxide and ZnO Nanorods-Modified Glassy Carbon Electrode for Uric Acid Detection
    Fu, Li
    Zheng, Yuhong
    Wang, Aiwu
    Cai, Wen
    Deng, Bo
    Zhang, Zhi
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2016, 41 (01) : 135 - 141
  • [39] An Electrochemical Sensor Based on Reduced Graphene Oxide and ZnO Nanorods-Modified Glassy Carbon Electrode for Uric Acid Detection
    Li Fu
    Yuhong Zheng
    Aiwu Wang
    Wen Cai
    Bo Deng
    Zhi Zhang
    Arabian Journal for Science and Engineering, 2016, 41 : 135 - 141
  • [40] Electrochemical detection of 4-nitrophenol based on a glassy carbon electrode modified with a reduced graphene oxide/Au nanoparticle composite
    Tang, Yanhong
    Huang, Run
    Liu, Chengbin
    Yang, Shanli
    Lu, Zhenzhen
    Luo, Shenglian
    ANALYTICAL METHODS, 2013, 5 (20) : 5508 - 5514