Electrochemical detection of DNA damage induced by clenbuterol at a reduced graphene oxide-Nafion modified glassy carbon electrode

被引:20
|
作者
Lin, Xiaoyun [1 ]
Ni, Yongnian [1 ,2 ]
Pei, Xueying [1 ]
Kokot, Serge [3 ]
机构
[1] Nanchang Univ, Sch Chem, Nanchang 330031, Jiangxi, Peoples R China
[2] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Jiangxi, Peoples R China
[3] Queensland Univ Technol, Sch Chem Phys & Mech Engn, Brisbane, Qld 4001, Australia
基金
中国国家自然科学基金;
关键词
QUANTITATIVE MEASUREMENT; METHYLENE-BLUE; IN-SITU; SENSOR; NANOPARTICLES; REDUCTION; TOXICITY; CATALYST; ACID; FILM;
D O I
10.1039/c6ay03022j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical biosensor capable of direct detection of DNA damage induced by clenbuterol (CLB) has been developed. A glassy carbon electrode (GCE) was modified using reduced graphene oxide-Nafion and dsDNA to produce a dsDNA/RGO-Nafion/GCE sensor. The modified electrode was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV), and the results at each stage of the electrode construction were interpreted. They indicated that the electrochemical oxidation peak currents of guanine and adenine at the electrode (dsDNA/RGO-Nafion/GCE) significantly increased as compared with those at the untreated electrode (dsDNA/GCE). Based on this, the sensor was used to measure the change of the oxidation peak currents for guanine and adenine between the intact and damaged dsDNA in the sensor films, and the DNA damage was successfully detected. Furthermore, the plot of peak current decline for the guanine and adenine versus the concentration of CLB was linear in the range of 5.0 x 10(-7) to 4.0 x 10(-6) mol L-1, with a limit of detection (LOD) of 3.2 x 10(-7) mol L-1, which provided a good method to determine CLB indirectly.
引用
收藏
页码:1105 / 1111
页数:7
相关论文
共 50 条
  • [22] Simultaneous Electrochemical Detection of Dopamine and Ascorbic Acid Using an Iron Oxide/Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Peik-See, Teo
    Pandikumar, Alagarsamy
    Nay-Ming, Huang
    Hong-Ngee, Lim
    Sulaiman, Yusran
    SENSORS, 2014, 14 (08): : 15227 - 15243
  • [23] Amperometric detection of nitric oxide using a glassy carbon electrode modified with gold nanoparticles incorporated into a nanohybrid composed of reduced graphene oxide and Nafion
    Norazriena Yusoff
    Perumal Rameshkumar
    Muhammad Mehmood Shahid
    Sheng-Tung Huang
    Nay Ming Huang
    Microchimica Acta, 2017, 184 : 3291 - 3299
  • [24] Amperometric detection of nitric oxide using a glassy carbon electrode modified with gold nanoparticles incorporated into a nanohybrid composed of reduced graphene oxide and Nafion
    Yusoff, Norazriena
    Rameshkumar, Perumal
    Shahid, Muhammad Mehmood
    Huang, Sheng-Tung
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2017, 184 (09) : 3291 - 3299
  • [25] Voltammetric Sensing of Bilirubin Based on Nafion/Electrochemically Reduced Graphene Oxide Composite Modified Glassy Carbon Electrode
    Avan, Asiye Aslihan
    Aydar, Sevda
    Filik, Hayati
    CURRENT ANALYTICAL CHEMISTRY, 2015, 11 (02) : 96 - 103
  • [26] Glassy carbon electrode modified with Nafion-Au colloids for clenbuterol electroanalysis
    Liu, Lijing
    Pan, Haibo
    Du, Min
    Xie, Wenqin
    Wang, Jian
    ELECTROCHIMICA ACTA, 2010, 55 (24) : 7240 - 7245
  • [27] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Li, Yamin
    Wu, Shufang
    Luo, Peili
    Liu, Jie
    Song, Ge
    Zhang, Kai
    Ye, Baoxian
    ANALYTICAL SCIENCES, 2012, 28 (05) : 497 - 502
  • [28] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Yamin Li
    Shufang Wu
    Peili Luo
    Jie Liu
    Ge Song
    Kai Zhang
    Baoxian Ye
    Analytical Sciences, 2012, 28 : 497 - 502
  • [29] Electrochemical determination of theophylline on a glassy carbon electrode modified with reduced graphene oxide-sodium dodecyl sulfate-Nafion composite film
    M. Hamidi
    K. Zarei
    Russian Chemical Bulletin, 2020, 69 : 2107 - 2112
  • [30] Electrochemical determination of theophylline on a glassy carbon electrode modified with reduced graphene oxide-sodium dodecyl sulfate-Nafion composite film
    Hamidi, M.
    Zarei, K.