Influence of implant-abutment connection structure on peri-implant bone level in a second molar: A 1-year randomized controlled trial

被引:7
|
作者
Kim, Jin-Cheol [1 ,2 ]
Lee, Jungwon [3 ]
Kim, Sungtae [4 ]
Koo, Ki-Tae [4 ]
Kim, Hae-Young [5 ]
Yeo, In-Sung Luke [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Prosthodont, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Dent Res Inst, 101 Daehak Ro, Seoul 03080, South Korea
[3] Seoul Natl Univ, Dept Periodontol, Dent Hosp, Seoul, South Korea
[4] Seoul Natl Univ, Dept Periodontol, Sch Dent, Seoul, South Korea
[5] Korea Univ, Coll Hlth Sci, Dept Hlth Policy & Management, Seoul, South Korea
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2019年 / 11卷 / 03期
基金
新加坡国家研究基金会;
关键词
Randomized controlled trial; Dental implant-abutment design; Alveolar bone loss; DIFFERENT PROSTHETIC INTERFACES; DENTAL IMPLANTS; RADIOGRAPHIC EVALUATION; EXTERNAL CONNECTIONS; NECK CONFIGURATIONS; TITANIUM IMPLANTS; MORSE TAPER; PLATFORM; RESISTANCE; OUTCOMES;
D O I
10.4047/jap.2019.11.3.147
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study aimed to evaluate the effect of two different implant-abutment connection structures with identical implant design on peri-implant bone level. MATERIALS AND METHODS. This clinical study was a patient-blind randomized controlled trial following the CONSORT 2010 checklists. This trial was conducted in 24 patients recruited between March 2013 and July 2015. Implants with internal friction connection were compared to those with external hex connection. One implant for each patient was installed, replacing the second molar. Implant-supported crowns were delivered at four months after implant insertion. Standardized periapical radiographs were taken at prosthesis delivery (baseline), and one year after delivery. On the radiographs, distance from implant shoulder to first bone-to-implant contact (DIB) and peri-implant area were measured, which were the primary and secondary outcome, respectively. RESULTS. Eleven external and eleven internal implants were analyzed. Mean changes of DIB from baseline to 1-year postloading were 0.59 (0.95) mm for the external and 0.01 (0.68) mm for the internal connection. Although no significant differences were found between the two groups, medium effect size was found in DIB between the connections (Cohen's d = 0.67). CONCLUSION. Considering the effect size in DIB, this study suggested the possibility of the internal friction connection structure for more effective preservation of marginal bone.
引用
收藏
页码:147 / 154
页数:8
相关论文
共 50 条
  • [31] Crestal bone changes in macrogeometrically similar implants with the implant-abutment connection at the crestal bone level or 2.5 mm above: a prospective randomized clinical trial
    van Eekeren, Paul
    Tahmaseb, Ali
    Wismeijer, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (12) : 1479 - 1484
  • [32] Probiotic supplements and debridement of peri-implant mucositis: A randomized controlled trial
    Hallstrom, Hadar
    Lindgren, Susann
    Widen, Cecilia
    Renvert, Stefan
    Twetman, Svante
    ACTA ODONTOLOGICA SCANDINAVICA, 2016, 74 (01) : 60 - 66
  • [33] May dental implant macro and microgeometry modifications influence peri-implant bone repair in smokers? A randomized clinical trial
    Cirano, Fabiano Ribeiro
    Obice, Andre Luis Seferian
    Girlanda, Felipe Fonseca
    Monteiro, Mabelle Freitas
    Pimentel, Suzana Peres
    Casati, Marcio Zaffalon
    Correa, Monica Grazieli
    BMC ORAL HEALTH, 2024, 24 (01):
  • [34] Biomechanical evaluation of stress distributions at the implant-abutment complex and peri-implant bone around mandibular dental implants with different neck geometries and inclinations
    Dinc, Murat M.
    Turkoglu, Pinar
    Selvi, Firat
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2021, 235 (09) : 1035 - 1045
  • [35] The effect of implant-abutment connections on peri-implant bone levels around single implants in the aesthetic zone: A systematic review and a meta-analysis
    Meijndert, Caroliene M.
    Raghoebar, Gerry M.
    Vissink, Arjan
    Delli, Konstantina
    Meijer, Henny J. A.
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2021, 7 (06): : 1025 - 1036
  • [36] Effect of Customized and Prefabricated Healing Abutments on Peri-Implant Soft Tissue and Bone in Immediate Implant Sites: A Randomized Controlled Trial
    Chokaree, Parima
    Poovarodom, Pongsakorn
    Chaijareenont, Pisaisit
    Rungsiyakull, Pimduen
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (03)
  • [37] Influence of Abutment Height on Maintenance of Peri-implant Crestal Bone at Bone-Level Implants: A 3-Year Follow-up Study
    Novoa, Lourdes
    Batalla, Pilar
    Caneiro, Leticia
    Pico, Alexandre
    Linares, Antonio
    Blanco, Juan
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2017, 37 (05) : 721 - 728
  • [38] Clinical and radiographic peri-implant tissue changes for implants restored with convex or concave abutment shapes: A 3-year randomized controlled trial
    Koutouzis, Theofilos
    Ali, Abdulaziz
    AlRubaie, Mohammed
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (07) : 675 - 683
  • [39] Comparing the Effectiveness of Different Techniques for the Management of Dental Implant Peri-Implant Mucositis: A Randomized Controlled Trial
    Gupta, Bharti
    Gupta, Shekhar
    Divya, Divya
    Dev, Shruti Vishal
    Bhola, Surabhi
    Guruprasad, Yadavalli
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S865 - S867
  • [40] The impact of implant abutment surface treatment with TiO2 on peri-implant levels of angiogenesis and bone-related markers: a randomized clinical trial
    Obice, A. L. S.
    Correa, M. G.
    Feng, H. S.
    Ribeiro, F., V
    Cirano, F. R.
    Casati, M. Z.
    Pimentel, S. P.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 48 (07) : 962 - 970