Influence of implant-abutment connection structure on peri-implant bone level in a second molar: A 1-year randomized controlled trial

被引:7
|
作者
Kim, Jin-Cheol [1 ,2 ]
Lee, Jungwon [3 ]
Kim, Sungtae [4 ]
Koo, Ki-Tae [4 ]
Kim, Hae-Young [5 ]
Yeo, In-Sung Luke [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Prosthodont, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Dent Res Inst, 101 Daehak Ro, Seoul 03080, South Korea
[3] Seoul Natl Univ, Dept Periodontol, Dent Hosp, Seoul, South Korea
[4] Seoul Natl Univ, Dept Periodontol, Sch Dent, Seoul, South Korea
[5] Korea Univ, Coll Hlth Sci, Dept Hlth Policy & Management, Seoul, South Korea
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2019年 / 11卷 / 03期
基金
新加坡国家研究基金会;
关键词
Randomized controlled trial; Dental implant-abutment design; Alveolar bone loss; DIFFERENT PROSTHETIC INTERFACES; DENTAL IMPLANTS; RADIOGRAPHIC EVALUATION; EXTERNAL CONNECTIONS; NECK CONFIGURATIONS; TITANIUM IMPLANTS; MORSE TAPER; PLATFORM; RESISTANCE; OUTCOMES;
D O I
10.4047/jap.2019.11.3.147
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study aimed to evaluate the effect of two different implant-abutment connection structures with identical implant design on peri-implant bone level. MATERIALS AND METHODS. This clinical study was a patient-blind randomized controlled trial following the CONSORT 2010 checklists. This trial was conducted in 24 patients recruited between March 2013 and July 2015. Implants with internal friction connection were compared to those with external hex connection. One implant for each patient was installed, replacing the second molar. Implant-supported crowns were delivered at four months after implant insertion. Standardized periapical radiographs were taken at prosthesis delivery (baseline), and one year after delivery. On the radiographs, distance from implant shoulder to first bone-to-implant contact (DIB) and peri-implant area were measured, which were the primary and secondary outcome, respectively. RESULTS. Eleven external and eleven internal implants were analyzed. Mean changes of DIB from baseline to 1-year postloading were 0.59 (0.95) mm for the external and 0.01 (0.68) mm for the internal connection. Although no significant differences were found between the two groups, medium effect size was found in DIB between the connections (Cohen's d = 0.67). CONCLUSION. Considering the effect size in DIB, this study suggested the possibility of the internal friction connection structure for more effective preservation of marginal bone.
引用
收藏
页码:147 / 154
页数:8
相关论文
共 50 条
  • [1] Influence of Abutment Design and Platform Switching on Peri-implant Marginal Bone Level: A Randomized Controlled Clinical Trial with 1-Year Results
    Cardaropoli, Daniele
    Tamagnone, Lorenzo
    Roffredo, Alessandro
    Gaveglio, Lorena
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2021, 41 (04) : 547 - +
  • [2] Implant-abutment connection as contributing factor to peri-implant diseases
    Koutouzis, Theofilos
    PERIODONTOLOGY 2000, 2019, 81 (01) : 152 - 166
  • [3] The influence of implant-abutment connection to peri-implant bone loss: A systematic review and meta-analysis
    Caricasulo, Riccardo
    Malchiodi, Luciano
    Ghensi, Paolo
    Fantozzi, Giuliano
    Cucchi, Alessandro
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (04) : 653 - 664
  • [4] Influence of abutment height and implant depth position on interproximal peri-implant bone in sites with thin mucosa: A 1-year randomized clinical trial
    Pico, Alexandre
    Martin-Lancharro, Pablo
    Caneiro, Leticia
    Novoa, Lourdes
    Batalla, Pilar
    Blanco, Juan
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (07) : 595 - 602
  • [5] The influence of the implant-abutment complex on marginal bone and peri-implant conditions: A retrospective study
    Tokgoz, Selen Ergin
    Bilhan, Hakan
    JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (01): : 46 - 54
  • [6] Influence of implant neck design and implant-abutment connection type on peri-implant health. Radiological study
    Penarrocha-Diago, M. A.
    Flichy-Fernandez, A. J.
    Alonso-Gonzalez, R.
    Penarrocha-Oltra, D.
    Balaguer-Martinez, J.
    Penarrocha-Diago, M.
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (11) : 1192 - 1200
  • [7] Peri-implant bone-level changes in the second decade of loading with regard to the implant-abutment connection: a retrospective study on implants under systematic aftercare
    Kruse, Anne Brigitte
    Wild, Vanessa
    Ratka-Kruger, Petra
    Vach, Kirstin
    Frisch, Eberhard
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [8] Influence of abutment disconnection on peri-implant marginal bone loss: A randomized clinical trial
    Praca, Luciano de Freitas Guimaraes
    Teixeira, Renata Cordeiro
    Rego, Rodrigo Otavio
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (04) : 341 - 351
  • [9] Electronic assessment of peri-implant mucosal esthetics around three implant-abutment configurations: a randomized clinical trial
    Barwacz, Christopher A.
    Stanford, Clark M.
    Diehl, Ursula A.
    Qian, Fang
    Cooper, Lyndon F.
    Feine, Jocelyne
    McGuire, Michael
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (06) : 707 - 715
  • [10] Influence of the abutment height and connection timing in early peri-implant marginal bone changes: A prospective randomized clinical trial
    Borges, Tiago
    Leitao, Bruno
    Pereira, Miguel
    Carvalho, Agata
    Galindo-Moreno, Pablo
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (09) : 907 - 914