X-ray luminescence tomography (XLT) is an imaging technology based on X-ray-excitable materials. The main purpose of this paper is to obtain quantitative luminescence concentration using the structural information of the X-ray computed tomography (XCT) in the hybrid cone beam XLT/XCT system. A multi-wavelength luminescence cone beam XLT method with the structural a priori information is presented to relieve the severe ill-posedness problem in the cone beam XLT. The nanophosphors and phantom experiments were undertaken to access the linear relationship of the system response. Then, an in vivo mouse experiment was conducted. The in vivo experimental results show that the recovered concentration error as low as 6.67% with the location error of 0.85mm can be achieved. The results demonstrate that the proposed method can accurately recover the nanophosphor inclusion and realize the quantitative imaging. (C) 2014 AIP Publishing LLC.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Cone-beam x-ray tomography with arbitrary-orientation x-ray tube
    Sueseenak, D.
    Chanwimalueang, T.
    Narkbuekaew, W.
    Chitsakul, K.
    Pintavirooj, C.
    ICIEA 2006: 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, PROCEEDINGS, 2006, : 1631 - 1634
  • [42] Cone-beam X-ray tomography with arbitrary-orientation X-ray ribe
    Sueseenak, D.
    Chanwimalueang, T.
    Narkbuekaew, W.
    Chitsakul, K.
    Pintavirooj, C.
    2006 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, 2006, : 1300 - +
  • [43] Cone Beam X-Ray Luminescence Computed Tomography Based On Generalized Gaussian Markov Random Field
    Zhang, G.
    Xing, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3678 - 3678
  • [44] MLEM reconstruction with specific initial image for cone-beam x-ray luminescence computed tomography
    Ruan, Jiabin
    Gao, Peng
    Liu, Tianshuai
    Zhan, Yonghua
    Lu, Hongbing
    Rong, Junyan
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [45] QUANTITATIVE ANALYSIS OF COMPUTED TOMOGRAPHY AND X-RAY IN BRONCHIECTASIS
    Clark, A.
    Byrnes, C.
    RESPIROLOGY, 2014, 19 : 20 - 20
  • [46] X-ray luminescence computed tomography imaging based on X-ray distribution model and adaptively split Bregman method
    Chen, Dongmei
    Zhu, Shouping
    Cao, Xu
    Zhao, Fengjun
    Liang, Jimin
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (07): : 2649 - 2663
  • [47] Application of x-ray image magnifier and demagnifier to parallel beam x-ray computed tomography
    Hirano, K.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2011, 44 (05)
  • [48] X-ray computed tomography using projection X-ray microscope
    Yoshimura, F
    Miyata, C
    Kuzuryu, C
    Hori, A
    Obi, T
    Ohyama, N
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 166 - 171
  • [49] Imaging of Rock Pores by X-ray Computed Tomography
    Nakashima, Yoshito
    JOURNAL OF GEOGRAPHY-CHIGAKU ZASSHI, 2005, 114 (06) : 1032 - 1043
  • [50] Dimensional accuracy in X-ray computed tomography imaging
    Neel, ST
    Gibson, R
    Daniels, CR
    Klosterman, EL
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, 1998, : 411 - 418