Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging

被引:29
|
作者
Chen, Dongmei [1 ,2 ]
Zhu, Shouping [1 ,2 ]
Chen, Xueli [1 ,2 ]
Chao, Tiantian [1 ,2 ]
Cao, Xu [1 ,2 ]
Zhao, Fengjun [1 ,2 ]
Huang, Liyu [1 ,2 ]
Liang, Jimin [1 ,2 ]
机构
[1] Xidian Univ, Minist Educ, Engn Res Ctr Mol & Neuro Imaging, Xian 710071, Shaanxi, Peoples R China
[2] Xidian Univ, Sch Life Sci & Technol, Xian 710071, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
RECONSTRUCTION;
D O I
10.1063/1.4901436
中图分类号
O59 [应用物理学];
学科分类号
摘要
X-ray luminescence tomography (XLT) is an imaging technology based on X-ray-excitable materials. The main purpose of this paper is to obtain quantitative luminescence concentration using the structural information of the X-ray computed tomography (XCT) in the hybrid cone beam XLT/XCT system. A multi-wavelength luminescence cone beam XLT method with the structural a priori information is presented to relieve the severe ill-posedness problem in the cone beam XLT. The nanophosphors and phantom experiments were undertaken to access the linear relationship of the system response. Then, an in vivo mouse experiment was conducted. The in vivo experimental results show that the recovered concentration error as low as 6.67% with the location error of 0.85mm can be achieved. The results demonstrate that the proposed method can accurately recover the nanophosphor inclusion and realize the quantitative imaging. (C) 2014 AIP Publishing LLC.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] X-ray luminescence computed tomography: a sensitivity study
    Lun, Michael C.
    Zhang, Wei
    Li, Changqing
    MEDICAL IMAGING 2017: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2017, 10137
  • [32] Sensitivity study of x-ray luminescence computed tomography
    Lun, Michael C.
    Zhang, Wei
    Li, Changqing
    APPLIED OPTICS, 2017, 56 (11) : 3010 - 3019
  • [33] Quantitative X-ray tomography
    Maire, E.
    Withers, P. J.
    INTERNATIONAL MATERIALS REVIEWS, 2014, 59 (01) : 1 - 43
  • [34] Excitation-resolved cone-beam x-ray luminescence tomography
    Liu, Xin
    Liao, Qimei
    Wang, Hongkai
    Yan, Zhuangzhi
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (07)
  • [35] X-RAY FAN-BEAM LUMINESCENCE TOMOGRAPHY
    Cong, Wenxiang
    Wang, Ge
    2014 IEEE 11TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2014, : 1164 - 1167
  • [36] Three-dimensional imaging using X-ray cone-beam computed tomography
    Kawai, H
    Sekihara, K
    Ueda, K
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 965 - 965
  • [37] Performance evaluation of the simplified spherical harmonics approximation for cone-beam X-ray luminescence computed tomography imaging
    Zhang, Haibo
    Geng, Guohua
    Chen, Yanrong
    Zhao, Fengjun
    Hou, Yuqing
    Yi, Huangjian
    Zhang, Shunli
    Yu, Jingjing
    He, Xiaowei
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2017, 10 (03)
  • [38] X-ray Cone-Beam Breast Computed Tomography: phantom studies
    Russo, P.
    Lauria, A.
    Mettivier, G.
    Montesi, M. C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4076 - 4083
  • [39] X-ray Cone-Beam Breast Computed Tomography: Phantom Studies
    Russo, Paolo
    Mettivier, Giovanni
    Lauria, Adele
    Montesi, Maria Cristina
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 160 - 172
  • [40] Multi-mounted X-ray cone-beam computed tomography
    Fu, Jian
    Wang, Jingzheng
    Guo, Wei
    Peng, Peng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 888 : 119 - 125