Circuit Breaker Transient Recovery Voltage in Presence of Source Side Shunt Capacitor Bank

被引:0
|
作者
Kandakatla, Murali [1 ]
Rao, B. Kondala [1 ]
Gajjar, Gopal [1 ]
机构
[1] ABB Ltd, Vadodara, India
关键词
Arcing time; High frequency discharge current; Initial Transient Recovery Voltage (ITRV); Rate of Rise of Recovery Voltage (RRRV); Re-ignition; Restrike; Shunt capacitor bank; Transient Recovery Voltage (TRV);
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Reactive power compensation through connection of shunt capacitor banks is a common practice in medium voltage systems. But the presence of capacitor bank leads to some interesting phenomena in switching transients. Clearing of a fault on line side of breaker in the presence of a source side capacitor bank is one such phenomenon. While clearing the fault if there is any re-ignition, presence of capacitor bank will develop high frequency discharge current that is superimposed on the power frequency fault current. Interruption of this high frequency current would cause considerable increase in the TRV magnitude. This paper describes the above phenomenon with PSCAD simulation results of a practical system. It also explains the effect of various parameters on the breaker TRV magnitude.
引用
收藏
页码:606 / 611
页数:6
相关论文
共 50 条
  • [21] Vacuum Circuit Breaker's Electrical Life for Shunt Capacitor Switching
    Griot, S.
    Moreau, A.
    ISDEIV 2010: XXIVTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, 2010, : 193 - 196
  • [22] Transient recovery voltage analysis for various current breaking mathematical models: shunt reactor and capacitor bank de-energization study
    Oramus, Piotr
    Chmielewski, Tomasz
    Kuczek, Tomasz
    Piasecki, Wojciech
    Szewczyk, Marcin
    ARCHIVES OF ELECTRICAL ENGINEERING, 2015, 64 (03) : 441 - 458
  • [23] Mitigation of Capacitor Bank Switching Transients by Using SVCs in Large Plants Instead of Capacitor bank and Circuit Breaker
    Taherzadeh, M.
    Rostaminia, R.
    Joorabian, M.
    Saniei, M.
    4TH ANNUAL INTERNATIONAL POWER ELECTRONICS, DRIVE SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC 2013), 2013, : 321 - 327
  • [24] A simulation model of a middle-voltage shunt circuit breaker
    Bizjak, Grega
    Žunko, Peter
    Elektrotehniski Vestnik/Electrotechnical Review, 2002, 69 (05): : 279 - 284
  • [25] Analysis of a SVC Device Filter Capacitor Bank Circuit Breaker Explosion
    Quan, Jiexiong
    Wen, Caiquan
    2020 6TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY, ENVIRONMENT AND CHEMICAL ENGINEERING, PTS 1-5, 2020, 546
  • [26] A UNIQUE MULTIPURPOSE DAMPING CIRCUIT FOR SHUNT CAPACITOR BANK SWITCHING
    SABOT, A
    MORIN, C
    GUILLAUME, C
    PONS, A
    TAISNE, JP
    LOPIZZO, G
    MORF, HU
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) : 1173 - 1183
  • [27] GENERATOR CIRCUIT-BREAKER TRANSIENT RECOVERY VOLTAGE IN MOST SEVERE SHORT-CIRCUIT CONDITIONS.
    Ruoss, E.
    1600,
  • [28] A Proposed Transient Recovery Voltage Mitigation Technique For Generator-Circuit-Breaker Fed Faults
    Badran, Ebrahim A.
    Abd-Allah, M. A.
    Hamza, Abdelsalam H.
    Elyan, Tamer
    JOURNAL OF ELECTRICAL SYSTEMS, 2013, 9 (01) : 66 - 72
  • [29] POWER CIRCUIT-BREAKER TRANSIENT RECOVERY VOLTAGES
    HEDMAN, DE
    LAMBERT, SR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (01): : 197 - 207
  • [30] Current situation and countermeasures of switching capacitor bank using vacuum circuit breaker
    Li, Dian
    Jin, Bai-Rong
    Hong, Jin-Qi
    Qiu, Yong
    Gaoya Dianqi/High Voltage Apparatus, 2003, 39 (05):