We prepared polyhydroxybutyrate/valerate (PHBV)/polylcaprolactone (PCL) small-diameter vascular grafts using electrospinning. Surface structure was assessed by scanning electron microscopy whilst physicomechanical properties were investigated by longitudinal uniaxial tension testing. Patency of grafts implanted into the rat abdominal aorta was evaluated using a Doppler ultrasonography at 2 week, 1 month and 12 month postimplantation. In addition, we assessed local histological features, along with IL-1 beta, IL-2, IL-4, IL-10, TNF alpha, TGF-beta 1, and VEGF serum levels. We revealed that only 2 (25%) grafts were not thrombosed at 2 week and 1 month postimplantation. However, at 12 month postimplantation a satisfactory histological pattern was observed in 50% of all cases, and we detected a monolayer of endothelial cells on the inner graft surface in half the cases. Regarding other grafts, we revealed minor connective tissue hyperplasia in 41.7% of the grafts and an inflammatory infiltrate in the part of the arterial wall in 8.3% of the grafts. We found that the IL-1 beta serum level was 3.5-fold higher in the group of experimental rats at 12 month postimplantation (p < 0.01). In addition, the IL-2 and IL-4 serum levels at 12 month postimplantation were 2-and 2.8-fold higher as compared to short-term implantation (2 weeks and 1 month) and control rats (p < 0.05) whilst the IL-10 serum level at 1 and 12 month postimplantation was more than 100-fold higher in comparison with 2 week postimplantation and control rats (p < 0.001). Serum VEGF was detected only at 12 month postimplantation. All in all, we created a biocompatible PHBV/PCL small-diameter vascular graft with a high surface area to volume ratio. A long-term patency of biodegradable vascular grafts after implantation into the rat abdominal aorta and the absence of a considerable immune response confirmed a high biocompatibility of such construct and the possibility of its use as a vascular graft.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Small-diameter vascular tissue engineering
    Dawit G. Seifu
    Agung Purnama
    Kibret Mequanint
    Diego Mantovani
    Nature Reviews Cardiology, 2013, 10 : 410 - 421
  • [32] Fabrication of Endothelial Cell-Lining Polyurethane/Polycaprolactone Tubular Scaffold Coated with Conjugated Linoleic Acid for Small-Diameter Vascular Graft
    Vu, Binh Thanh
    Nguyen, Phuc Dang-Ngoc
    Tran, Nam Minh-Phuong
    Tang, Tuan-Ngan
    Do, Thai Minh
    Vo, Toi Van
    Nguyen, Hiep Thi
    FIBERS AND POLYMERS, 2023, 24 (02) : 423 - 432
  • [33] ELASTIC PROPERTIES AND STRENGTH OF A NOVEL SMALL-DIAMETER, COMPLIANT POLYURETHANE VASCULAR GRAFT
    HAYASHI, K
    TAKAMIZAWA, K
    SAITO, T
    KIRA, K
    HIRAMATSU, K
    KONDO, K
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH-APPLIED BIOMATERIALS, 1989, 23 (A2): : 229 - 244
  • [34] AN EXPERIMENTAL-STUDY OF EVAPORATING SMALL-DIAMETER JETS
    KOWALEWSKI, TA
    HILLER, WJ
    BEHNIA, M
    PHYSICS OF FLUIDS A-FLUID DYNAMICS, 1993, 5 (08): : 1883 - 1890
  • [35] The Decellularized Vascular Allograft as an Experimental Platform for Developing a Biocompatible Small-Diameter Graft Conduit in a Rat Surgical Model
    Hwang, Seong-Jun
    Kim, Seong Who
    Choo, Suk Jung
    Lee, Byoung Wook
    Im, I-rang
    Yun, Hye Joo
    Lee, Sang Kwon
    Song, Hyun
    Cho, Won Chul
    Lee, Jae Won
    YONSEI MEDICAL JOURNAL, 2011, 52 (02) : 227 - 233
  • [36] Experimental Study on Strain Sensing by Small-Diameter FBG
    Liu, Rong-mei
    Li, Qiufeng
    Zhu, Lujia
    Liang, Dakai
    SECOND INTERNATIONAL SEMINAR ON PHOTONICS, OPTICS, AND ITS APPLICATIONS (ISPHOA 2016), 2016, 10150
  • [37] In vitro endothelial differentiation evaluation on polycaprolactone-methoxy polyethylene glycol electrospun membrane and fabrication of multilayered small-diameter hybrid vascular graft
    Amirian, Jhaleh
    Sultana, Tamanna
    Joo, Gyeong J.
    Park, Chanmi
    Lee, Byong-Taek
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2020, 34 (10) : 1395 - 1408
  • [38] Biologically modified bilayered antimicrobial polycaprolactone scaffolds for small diameter vascular graft applications
    Krishnan, K. K.
    Columbus, C. S.
    Krishnan, K. L.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2012, 6 : 146 - 146
  • [39] Cellular energy supply for promoting vascular remodeling of small-diameter vascular grafts: a preliminary study of a new strategy for vascular graft development
    Su, Hengxian
    Liu, Wenchao
    Li, Xifeng
    Li, Guangxu
    Guo, Shenquan
    Liu, Chang
    Yang, Tao
    Ou, Chubin
    Liu, Jiahui
    Li, Yuanzhi
    Wei, Chengcong
    Huang, Qing
    Xu, Tao
    Duan, Chuanzhi
    BIOMATERIALS SCIENCE, 2023, 11 (09) : 3197 - 3213
  • [40] Structure of Stretched PTFE Tube Used for Small-diameter Vascular Graft Characterized by SEM
    Wang Fujun
    Li Zhuo
    Zheng Kexi
    Luo Zhenxin
    Wang Lu
    2008 INTERNATIONAL SYMPOSIUM ON FIBER BASED SCAFFOLDS FOR TISSUE ENGINEERING, PROCEEDINGS, 2008, : 244 - 248