Polyhydroxybutyrate/Valerate/Polycaprolactone Small-Diameter Vascular Graft: Experimental Study of Integration into Organism

被引:1
|
作者
Antonova, L. V. [1 ]
Burago, A. Yu. [1 ]
Mironov, A. V. [2 ]
Matveeva, V. G. [1 ]
Velikanova, E. A. [1 ]
Mukhamadiyarov, R. A. [1 ]
Glushkova, T. V. [1 ]
Kudryavtseva, Y. A. [1 ]
Barbarash, O. L. [1 ]
Barbarash, L. S. [1 ]
机构
[1] Res Inst Complex Issues Cardiovasc Dis, Kemerovo, Russia
[2] Kemerovo Cardiol Dispensary, Kemerovo, Russia
关键词
D O I
10.1063/1.4932700
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We prepared polyhydroxybutyrate/valerate (PHBV)/polylcaprolactone (PCL) small-diameter vascular grafts using electrospinning. Surface structure was assessed by scanning electron microscopy whilst physicomechanical properties were investigated by longitudinal uniaxial tension testing. Patency of grafts implanted into the rat abdominal aorta was evaluated using a Doppler ultrasonography at 2 week, 1 month and 12 month postimplantation. In addition, we assessed local histological features, along with IL-1 beta, IL-2, IL-4, IL-10, TNF alpha, TGF-beta 1, and VEGF serum levels. We revealed that only 2 (25%) grafts were not thrombosed at 2 week and 1 month postimplantation. However, at 12 month postimplantation a satisfactory histological pattern was observed in 50% of all cases, and we detected a monolayer of endothelial cells on the inner graft surface in half the cases. Regarding other grafts, we revealed minor connective tissue hyperplasia in 41.7% of the grafts and an inflammatory infiltrate in the part of the arterial wall in 8.3% of the grafts. We found that the IL-1 beta serum level was 3.5-fold higher in the group of experimental rats at 12 month postimplantation (p < 0.01). In addition, the IL-2 and IL-4 serum levels at 12 month postimplantation were 2-and 2.8-fold higher as compared to short-term implantation (2 weeks and 1 month) and control rats (p < 0.05) whilst the IL-10 serum level at 1 and 12 month postimplantation was more than 100-fold higher in comparison with 2 week postimplantation and control rats (p < 0.001). Serum VEGF was detected only at 12 month postimplantation. All in all, we created a biocompatible PHBV/PCL small-diameter vascular graft with a high surface area to volume ratio. A long-term patency of biodegradable vascular grafts after implantation into the rat abdominal aorta and the absence of a considerable immune response confirmed a high biocompatibility of such construct and the possibility of its use as a vascular graft.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] A computational study of structural designs for a small-diameter composite vascular graft promoting tissue regeneration
    Sirry M.S.
    Zilla P.
    Franz T.
    Cardiovascular Engineering and Technology, 2010, 1 (4) : 269 - 281
  • [22] Wavy small-diameter vascular graft made of eggshell membrane and thermoplastic polyurethane
    Yan, Shujie
    Napiwocki, Brett
    Xu, Yiyang
    Zhang, Jue
    Zhang, Xiang
    Wang, Xiaofeng
    Crone, Wendy C.
    Li, Qian
    Turng, Lih-Sheng
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 107
  • [23] Fabrication of Endothelial Cell-Lining Polyurethane/Polycaprolactone Tubular Scaffold Coated with Conjugated Linoleic Acid for Small-Diameter Vascular Graft
    Binh Thanh Vu
    Phuc Dang-Ngoc Nguyen
    Nam Minh-Phuong Tran
    Tuan-Ngan Tang
    Thai Minh Do
    Toi Van Vo
    Hiep Thi Nguyen
    Fibers and Polymers, 2023, 24 : 423 - 432
  • [24] The Use of Antithrombotic Therapies in Reducing Synthetic Small-Diameter Vascular Graft Thrombosis
    Tatterton, Mark
    Wilshaw, Stacy-Paul
    Ingham, Eileen
    Homer-Vanniasinkam, Shervanthi
    VASCULAR AND ENDOVASCULAR SURGERY, 2012, 46 (03) : 212 - 222
  • [25] Application of subcutaneous extracellular matrix to prepare bilayer heparin-coated polycaprolactone/decellularized small-diameter vascular graft for tissue regeneration
    Xu, Zeqin
    Geng, Xue
    Ye, Lin
    Li, Liqiang
    Xing, Yuehao
    Cheng, Jin
    Wang, Cong
    Gu, Yongquan
    Tong, Zhu
    Guo, Lianrui
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2025, 289
  • [26] Development of Small-Diameter Vascular Grafts
    Xinwen Wang
    Peter Lin
    Qizhi Yao
    Changyi Chen
    World Journal of Surgery, 2007, 31 : 682 - 689
  • [27] POLYPROPYLENE SMALL-DIAMETER VASCULAR GRAFTS
    GREISLER, HP
    TATTERSALL, CW
    HENDERSON, SC
    CABUSAO, EA
    GARFIELD, JD
    KIM, DU
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (10): : 1383 - 1394
  • [28] Development of small-diameter vascular grafts
    Wang, Xinwen
    Lin, Peter
    Yao, Qizhi
    Chen, Changyi
    WORLD JOURNAL OF SURGERY, 2007, 31 (04) : 682 - 689
  • [29] Novel Bioresorbable Vascular Graft With Sponge-Type Scaffold as a Small-Diameter Arterial Graft
    Sugiura, Tadahisa
    Tara, Shuhei
    Nakayama, Hidetaka
    Kurobe, Hirotsugu
    Yi, Tai
    Lee, Yong-Ung
    Lee, Avione Y.
    Breuer, Christopher K.
    Shinoka, Toshiharu
    ANNALS OF THORACIC SURGERY, 2016, 102 (03): : 720 - 727
  • [30] Small-diameter vascular tissue engineering
    Seifu, Dawit G.
    Purnama, Agung
    Mequanint, Kibret
    Mantovani, Diego
    NATURE REVIEWS CARDIOLOGY, 2013, 10 (07) : 410 - 421