Polyhydroxybutyrate/Valerate/Polycaprolactone Small-Diameter Vascular Graft: Experimental Study of Integration into Organism

被引:1
|
作者
Antonova, L. V. [1 ]
Burago, A. Yu. [1 ]
Mironov, A. V. [2 ]
Matveeva, V. G. [1 ]
Velikanova, E. A. [1 ]
Mukhamadiyarov, R. A. [1 ]
Glushkova, T. V. [1 ]
Kudryavtseva, Y. A. [1 ]
Barbarash, O. L. [1 ]
Barbarash, L. S. [1 ]
机构
[1] Res Inst Complex Issues Cardiovasc Dis, Kemerovo, Russia
[2] Kemerovo Cardiol Dispensary, Kemerovo, Russia
关键词
D O I
10.1063/1.4932700
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We prepared polyhydroxybutyrate/valerate (PHBV)/polylcaprolactone (PCL) small-diameter vascular grafts using electrospinning. Surface structure was assessed by scanning electron microscopy whilst physicomechanical properties were investigated by longitudinal uniaxial tension testing. Patency of grafts implanted into the rat abdominal aorta was evaluated using a Doppler ultrasonography at 2 week, 1 month and 12 month postimplantation. In addition, we assessed local histological features, along with IL-1 beta, IL-2, IL-4, IL-10, TNF alpha, TGF-beta 1, and VEGF serum levels. We revealed that only 2 (25%) grafts were not thrombosed at 2 week and 1 month postimplantation. However, at 12 month postimplantation a satisfactory histological pattern was observed in 50% of all cases, and we detected a monolayer of endothelial cells on the inner graft surface in half the cases. Regarding other grafts, we revealed minor connective tissue hyperplasia in 41.7% of the grafts and an inflammatory infiltrate in the part of the arterial wall in 8.3% of the grafts. We found that the IL-1 beta serum level was 3.5-fold higher in the group of experimental rats at 12 month postimplantation (p < 0.01). In addition, the IL-2 and IL-4 serum levels at 12 month postimplantation were 2-and 2.8-fold higher as compared to short-term implantation (2 weeks and 1 month) and control rats (p < 0.05) whilst the IL-10 serum level at 1 and 12 month postimplantation was more than 100-fold higher in comparison with 2 week postimplantation and control rats (p < 0.001). Serum VEGF was detected only at 12 month postimplantation. All in all, we created a biocompatible PHBV/PCL small-diameter vascular graft with a high surface area to volume ratio. A long-term patency of biodegradable vascular grafts after implantation into the rat abdominal aorta and the absence of a considerable immune response confirmed a high biocompatibility of such construct and the possibility of its use as a vascular graft.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Small-diameter decellularized vascular graft with electrospun polycaprolactone
    Cuenca, John Patrick
    Padalhin, Andrew
    Lee, Byong-Taek
    MATERIALS LETTERS, 2021, 284
  • [2] Therapeutic strategies for small-diameter vascular graft calcification
    Teng, Yanjiao
    Xu, Yang
    Lv, Pengfei
    Song, Lin
    Yang, Jianing
    Wang, Xiudan
    Guo, Xiaoqin
    Wang, Shufang
    Hou, Shike
    Lv, Qi
    Shi, Jie
    CHEMICAL ENGINEERING JOURNAL, 2024, 487
  • [3] Develop A Small-diameter Vascular Graft With Amniotic Membrane
    Wang, B.
    TISSUE ENGINEERING PART A, 2023, 29 (9-10)
  • [4] Small-diameter vascular graft prostheses: Current status
    Bos, GW
    Poot, AA
    Beugeling, T
    van Aken, WG
    Feijen, J
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 1998, 106 (02) : 100 - 115
  • [5] Future Perspectives in Small-Diameter Vascular Graft Engineering
    Mallis, Panagiotis
    Kostakis, Alkiviadis
    Stavropoulos-Giokas, Catherine
    Michalopoulos, Efstathios
    BIOENGINEERING-BASEL, 2020, 7 (04): : 1 - 40
  • [6] Tailored electrospun small-diameter graft for vascular prosthesis
    Ferrari, Pier Francesco
    Aliakbarian, Bahar
    Lagazzo, Alberto
    Tamayol, Ali
    Palombo, Domenico
    Perego, Patrizia
    INTERNATIONAL JOURNAL OF POLYMERIC MATERIALS AND POLYMERIC BIOMATERIALS, 2017, 66 (12) : 635 - 643
  • [7] Effect of porosity on small-diameter vascular graft healing
    Contreras, MA
    Quist, WC
    LoGerfo, FW
    MICROSURGERY, 2000, 20 (01) : 15 - 21
  • [8] Small-diameter hybrid vascular grafts composed of polycaprolactone and polydioxanone fibers
    Pan, Yiwa
    Zhou, Xin
    Wei, Yongzhen
    Zhang, Qiuying
    Wang, Ting
    Zhu, Meifeng
    Li, Wen
    Huang, Rui
    Liu, Ruming
    Chen, Jingrui
    Fan, Guanwei
    Wang, Kai
    Kong, Deling
    Zhao, Qiang
    SCIENTIFIC REPORTS, 2017, 7
  • [9] Small-diameter hybrid vascular grafts composed of polycaprolactone and polydioxanone fibers
    Yiwa Pan
    Xin Zhou
    Yongzhen Wei
    Qiuying Zhang
    Ting Wang
    Meifeng Zhu
    Wen Li
    Rui Huang
    Ruming Liu
    Jingrui Chen
    Guanwei Fan
    Kai Wang
    Deling Kong
    Qiang Zhao
    Scientific Reports, 7
  • [10] A Small-diameter Decellularized Vascular Graft Covered with Electrospun Fibers
    Kimura, T.
    Morita, H.
    Wu, P.
    Nakamura, N.
    Nam, K.
    Fujisato, T.
    Kishida, A.
    TISSUE ENGINEERING PART A, 2015, 21 : S239 - S239