Implantable Acceleration Plethysmography for Blood Pressure Determination

被引:0
|
作者
Theodor, Michael [1 ]
Ruh, Dominic [1 ]
Foerster, Katharina [2 ]
Heilmann, Claudia [2 ]
Beyersdorf, Friedhelm [2 ]
Zappe, Hans [1 ]
Seifert, Andreas [1 ]
机构
[1] Univ Freiburg, Dept Microsyst Engn, IMTEK, Georges Koehler Allee 102, D-79110 Freiburg, Germany
[2] Univ Heart Ctr Freiburg Bad Krozingen, F-79106 Freiberg, Germany
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents an implantable accelerometer which detects plethysmograms directly at an artery. The sensor provides a new method for continuous blood pressure monitoring. In vivo measurements indicate that the accelerometer is well suited for determining the Pulse Transit Time (PTT) and the Reflected Wave Transit Time (RWTT). Both parameters show a high correlation with the systolic blood pressure. By varying the blood pressure, it was seen that RWTT more closely agrees with theory than PTT. Through several blood pressure sweeps the RWTT, as detected by the accelerometer, coincided very well with the systolic blood pressure, with a correlation coefficient of 0.96 and mean deviation of 4.3% for 1800 pulses.
引用
收藏
页码:4038 / 4041
页数:4
相关论文
共 50 条
  • [31] Nocturnal Blood Pressure Estimation from Sleep Plethysmography Using Machine Learning
    Yilmaz, Gizem
    Lyu, Xingyu
    Ong, Ju Lynn
    Ling, Lieng Hsi
    Penzel, Thomas
    Yeo, B. T. Thomas
    Chee, Michael W. L.
    SENSORS, 2023, 23 (18)
  • [32] Video plethysmography for contactless blood pressure and heart rate measurement in perioperative care
    Pham, Chi
    Poorzargar, Khashayar
    Panesar, Darshan
    Lee, Kang
    Wong, Jean
    Parotto, Matteo
    Chung, Frances
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2024, 38 (01) : 121 - 130
  • [33] A thin-film pressure transducer for implantable and intravascular blood pressure sensing
    Starr, Peter
    Bartels, Keith
    Agrawal, C. Mauli
    Bailey, Steven
    SENSORS AND ACTUATORS A-PHYSICAL, 2016, 248 : 38 - 45
  • [34] Blood pressure and body constitution influence indices of blood flow estimated by strain-gauge plethysmography
    Neubauer-Geryk, J
    Bieniaszewski, L
    Kruszewski, P
    Swierblewska, E
    Kunicka, K
    Kuligowska-Jakubowska, M
    Krupa-Wojciechowska, B
    Wyrzykowski, B
    JOURNAL OF HYPERTENSION, 2002, 20 : S215 - S215
  • [35] Determination of the reaction acceleration effect at an elevated hydrostatic pressure
    D. A. Kornilov
    V. D. Kiselev
    A. I. Konovalov
    Russian Chemical Bulletin, 2017, 66 : 564 - 566
  • [36] Determination of the reaction acceleration effect at an elevated hydrostatic pressure
    Kornilov, D. A.
    Kiselev, V. D.
    Konovalov, A. I.
    RUSSIAN CHEMICAL BULLETIN, 2017, 66 (03) : 564 - 566
  • [37] Validation of a totally implantable blood flow, blood pressure and temperature biotelemetry system
    Pitsillides, Koullis
    Axelsson, Michael
    FASEB JOURNAL, 2009, 23
  • [38] Determination of blood pressure in newborns
    Da Silva Ribeiro, Manoel Antonio
    Ramos Garcia, Pedro Celiny
    Fiori, Renato Machado
    SCIENTIA MEDICA, 2007, 17 (03) : 156 - 167
  • [39] DETERMINATION OF BLOOD PRESSURE AT THE ANKLE
    WEISS, AJ
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1954, 155 (15): : 1332 - 1333
  • [40] DETERMINATION OF BLOOD-PRESSURE
    SIMPSON, FO
    NEW ZEALAND MEDICAL JOURNAL, 1978, 87 (607) : 188 - 188