Implantable Acceleration Plethysmography for Blood Pressure Determination

被引:0
|
作者
Theodor, Michael [1 ]
Ruh, Dominic [1 ]
Foerster, Katharina [2 ]
Heilmann, Claudia [2 ]
Beyersdorf, Friedhelm [2 ]
Zappe, Hans [1 ]
Seifert, Andreas [1 ]
机构
[1] Univ Freiburg, Dept Microsyst Engn, IMTEK, Georges Koehler Allee 102, D-79110 Freiburg, Germany
[2] Univ Heart Ctr Freiburg Bad Krozingen, F-79106 Freiberg, Germany
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents an implantable accelerometer which detects plethysmograms directly at an artery. The sensor provides a new method for continuous blood pressure monitoring. In vivo measurements indicate that the accelerometer is well suited for determining the Pulse Transit Time (PTT) and the Reflected Wave Transit Time (RWTT). Both parameters show a high correlation with the systolic blood pressure. By varying the blood pressure, it was seen that RWTT more closely agrees with theory than PTT. Through several blood pressure sweeps the RWTT, as detected by the accelerometer, coincided very well with the systolic blood pressure, with a correlation coefficient of 0.96 and mean deviation of 4.3% for 1800 pulses.
引用
收藏
页码:4038 / 4041
页数:4
相关论文
共 50 条
  • [21] Using Impedance-plethysmography Technique for Cuffless Blood Pressure Measurement
    Liu, Shing-Hong
    Cai, Guo-He
    Cheng, Da-Chuan
    Huang, Yung-Fa
    2017 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2017, : 395 - 398
  • [22] DETERMINATION OF RENAL BLOOD PULSE VOLUME + FLOW BY ELECTRICAL IMPEDANCE PLETHYSMOGRAPHY
    ALLISON, RD
    ROTH, GM
    LUFT, UC
    CIRCULATION, 1964, 30 (4S3) : 41 - &
  • [23] BLOOD PRESSURE EFFECT OF ADMINISTRATION OF REMOTE CARCINOGENS MEASURED BY FOOT PLETHYSMOGRAPHY
    SKORYNA, SC
    RUDIS, LA
    WEBSTER, DR
    CANCER RESEARCH, 1951, 11 (04) : 280 - 280
  • [24] Subcutaneous blood pressure monitoring with an implantable optical sensor
    Michael Theodor
    Dominic Ruh
    Jens Fiala
    Katharina Förster
    Claudia Heilmann
    Yiannos Manoli
    Friedhelm Beyersdorf
    Hans Zappe
    Andreas Seifert
    Biomedical Microdevices, 2013, 15 : 811 - 820
  • [25] Subcutaneous blood pressure monitoring with an implantable optical sensor
    Theodor, Michael
    Ruh, Dominic
    Fiala, Jens
    Foerster, Katharina
    Heilmann, Claudia
    Manoli, Yiannos
    Beyersdorf, Friedhelm
    Zappe, Hans
    Seifert, Andreas
    BIOMEDICAL MICRODEVICES, 2013, 15 (05) : 811 - 820
  • [26] Long term, implantable blood pressure monitoring systems
    Potkay, Joseph A.
    BIOMEDICAL MICRODEVICES, 2008, 10 (03) : 379 - 392
  • [27] Long term, implantable blood pressure monitoring systems
    Joseph A. Potkay
    Biomedical Microdevices, 2008, 10 : 379 - 392
  • [28] Frequency response of implantable blood pressure telemetry systems
    McCormick, Daniel
    Budgett, David M.
    Lim, Matthew K.
    Van Vliet, Bruce
    Nielsen, Poul F.
    Hu, Aiguo P.
    Malpas, Simon C.
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2010, 37 (08) : 862 - 869
  • [29] Video plethysmography for contactless blood pressure and heart rate measurement in perioperative care
    Chi Pham
    Khashayar Poorzargar
    Darshan Panesar
    Kang Lee
    Jean Wong
    Matteo Parotto
    Frances Chung
    Journal of Clinical Monitoring and Computing, 2024, 38 : 121 - 130
  • [30] Blood Pressure Measurement from Photo-plethysmography to Pulse Transit Time
    Myint, C. Z.
    Lim, King Hann
    Wong, Kiing Ing
    Gopalai, Alpha Agape
    Oo, Min Zin
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 496 - 501