Implantable Acceleration Plethysmography for Blood Pressure Determination

被引:0
|
作者
Theodor, Michael [1 ]
Ruh, Dominic [1 ]
Foerster, Katharina [2 ]
Heilmann, Claudia [2 ]
Beyersdorf, Friedhelm [2 ]
Zappe, Hans [1 ]
Seifert, Andreas [1 ]
机构
[1] Univ Freiburg, Dept Microsyst Engn, IMTEK, Georges Koehler Allee 102, D-79110 Freiburg, Germany
[2] Univ Heart Ctr Freiburg Bad Krozingen, F-79106 Freiberg, Germany
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents an implantable accelerometer which detects plethysmograms directly at an artery. The sensor provides a new method for continuous blood pressure monitoring. In vivo measurements indicate that the accelerometer is well suited for determining the Pulse Transit Time (PTT) and the Reflected Wave Transit Time (RWTT). Both parameters show a high correlation with the systolic blood pressure. By varying the blood pressure, it was seen that RWTT more closely agrees with theory than PTT. Through several blood pressure sweeps the RWTT, as detected by the accelerometer, coincided very well with the systolic blood pressure, with a correlation coefficient of 0.96 and mean deviation of 4.3% for 1800 pulses.
引用
收藏
页码:4038 / 4041
页数:4
相关论文
共 50 条
  • [1] NONINVASIVE DETERMINATION OF CENTRAL BLOOD-PRESSURE BY IMPEDANCE PLETHYSMOGRAPHY
    HERSCOVICI, H
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (06) : 617 - 625
  • [2] Implantable Impedance Plethysmography
    Theodor, Michael
    Ruh, Dominic
    Ocker, Martin
    Spether, Dominik
    Foerster, Katharina
    Heilmann, Claudia
    Beyersdorf, Friedhelm
    Manoli, Yiannos
    Zappe, Hans
    Seifert, Andreas
    SENSORS, 2014, 14 (08) : 14858 - 14872
  • [3] Implantable Sensor for Blood Pressure Determination via Pulse Transit Time
    Fiala, Jens
    Bingger, Philipp
    Foerster, Katharina
    Heilmann, Claudia
    Beyersdorf, Friedhelm
    Zappe, Hans
    Seifert, Andreas
    2010 IEEE SENSORS, 2010, : 1226 - 1229
  • [4] BLOOD PRESSURE ESTIMATION USING VIDEO PLETHYSMOGRAPHY
    Secerbegovic, A.
    Bergsland, J.
    Halvorsen, P. S.
    Suljanovic, N.
    Mujcic, A.
    Balasingham, I.
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 461 - 464
  • [5] IMPLANTABLE BLOOD PRESSURE TELEMETRY
    BALDINGE.E
    CASADEI, F
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND PHYSIK, 1970, 21 (04): : 675 - &
  • [6] DETERMINATION OF MANS BLOOD PRESSURE ON THE HUMAN CENTRIFUGE DURING POSITIVE ACCELERATION
    STURM, RE
    WOOD, EH
    LAMBERT, EH
    FEDERATION PROCEEDINGS, 1945, 4 (01) : 69 - 69
  • [7] Novel implantable pressure and acceleration sensor for bladder monitoring
    Soebadi, Mohammad Ayodhia
    Weydts, Tristan
    Brancato, Luigi
    Hakim, Lukman
    Puers, Robert
    De Ridder, Dirk
    INTERNATIONAL JOURNAL OF UROLOGY, 2020, 27 (06) : 543 - 550
  • [8] Progress in impedance plethysmography for measuring arterial blood pressure
    Blinov, AV
    Selivanov, EP
    MEASUREMENT TECHNIQUES USSR, 1995, 38 (08): : 942 - 946
  • [9] DIRECT DETERMINATION OF MANS BLOOD PRESSURE ON THE HUMAN CENTRIFUGE DURING POSITIVE ACCELERATION
    LAMBERT, EH
    WOOD, EH
    FEDERATION PROCEEDINGS, 1946, 5 (01) : 59 - 59
  • [10] Measurement of Central Systolic Blood Pressure by Pulse Volume Plethysmography With a Noninvasive Blood Pressure Monitor
    Sung, Shih-Hsien
    Cheng, Hao-Min
    Chuang, Shao-Yuan
    Shih, Yuan-Ta
    Wang, Kang-Ling
    Chen, Ying-Hwa
    Lin, Shing-Jong
    Yu, Wen-Chung
    Chen, Chen-Huan
    AMERICAN JOURNAL OF HYPERTENSION, 2012, 25 (05) : 542 - 548