Calibration Tools for Scanning Thermal Microscopy Probes Used in Temperature Measurement Mode

被引:6
|
作者
Nguyen, T. P. [1 ]
Thiery, L. [1 ]
Euphrasie, S. [1 ]
Lemaire, E. [2 ]
Khan, S. [2 ]
Briand, D. [2 ]
Aigouy, L. [3 ,4 ]
Gomes, S. [5 ]
Vairac, P. [1 ]
机构
[1] Univ Franche Comte, CNRS, ENSMM, UTBM,FEMTO ST Inst,UMR 6174, F-25030 Besancon, France
[2] Ecole Polytech Fed Lausanne, Soft Transducers Lab, CH-2002 Neuchatel, Switzerland
[3] ESPCI Paris, LPEM, F-75005 Paris, France
[4] Sorbonne Univ, PSL Res Univ, CNRS, F-75006 Paris, France
[5] Univ Claude Bernard Lyon 1, INSA Lyon, CNRS, Univ Lyon,CETHIL,UMR5008, F-69621 Villeurbanne, France
来源
关键词
scanning thermal microscopy; temperature measurement; calibration; microhotplate; NANOSCALE THERMOMETRY; HEAT-TRANSFER; CONTACT;
D O I
10.1115/1.4043381
中图分类号
O414.1 [热力学];
学科分类号
摘要
We demonstrate the functionality of a new active thermal microchip dedicated to the temperature calibration of scanning thermal microscopy (SThM) probes. The silicon micro-machined device consists in a suspended thin dielectric membrane in which a heating resistor with a circular area of 50 mu m in diameter was embedded. A circular calibration target of 10 mu m in diameter was patterned at the center and on top of the membrane on which the SThM probe can land. This target is a resistive temperature detector (RTD) that measures the surface temperature of the sample at the level of the contact area. This allows evaluating the ability of any SThM probe to measure a surface temperature in ambient air conditions. Furthermore, by looking at the thermal balance of the device, the heat dissipated through the probe and the different thermal resistances involved at the contact can be estimated. A comparison of the results obtained for two different SThM probes, microthermocouples and probes with a fluorescent particle is presented to validate the functionality of the micromachined device. Based on experiments and simulations, an analysis of the behavior of probes allows pointing out their performances and limits depending on the sample characteristics whose role is always preponderant. Finally, we also show that a smaller area of the temperature sensor would be required to assess the local disturbance at the contact point.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Active calibration reference of minimized height for characterization of scanning thermal microscopy systems
    Janus, Pawel
    Szmigiel, Dariusz
    Sierakowski, Andrzej
    Rudek, Maciej
    Gotszalk, Teodor
    ULTRAMICROSCOPY, 2021, 221
  • [42] Standard-based direct calibration method for scanning thermal microscopy nanoprobes
    Wielgoszewski, Grzegorz
    Babij, Michal
    Szeloch, Roman F.
    Gotszalk, Teodor
    SENSORS AND ACTUATORS A-PHYSICAL, 2014, 214 : 1 - 6
  • [43] Temperature sensor for scanning thermal microscopy based on photoluminescence of microcrystal
    Sayoud, A.
    Trannoy, N.
    Jouart, J-P.
    Grossel, Ph.
    Diaf, M.
    Duvaut, Th.
    INFRARED REMOTE SENSING AND INSTRUMENTATION XIX, 2011, 8154
  • [44] Calibration for single multi-mode fiber digital scanning microscopy imaging system
    Yin, Zhe
    Liu, Guodong
    Liu, Bingguo
    Gan, Yu
    Zhuang, Zhitao
    Chen, Fengdong
    SELECTED PAPERS OF THE PHOTOELECTRONIC TECHNOLOGY COMMITTEE CONFERENCES, 2015, 9795
  • [45] Modeling and calibration of micro/nano FBG temperature probe for scanning probe microscopy
    Liu, Zhenmin
    Chen, Na
    Li, Shaoying
    Liu, Yong
    Shang, Yana
    Chen, Zhenyi
    Pang, Fufei
    Wang, Tingyun
    OPTICS EXPRESS, 2023, 31 (12) : 19453 - 19462
  • [46] Quantitative temperature distribution measurements by non-contact scanning thermal microscopy using Wollaston probes under ambient conditions
    Zhang, Yun
    Zhu, Wenkai
    Han, Liang
    Borca-Tasciuc, Theodorian
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (01):
  • [47] BATCH FABRICATION OF SCANNING MICROSCOPY PROBES FOR THERMAL AND MAGNETIC IMAGING USING STANDARD MICROMACHINING
    Sarajlic, E.
    Vermeer, R.
    Delalande, M. Y.
    Siekman, M. H.
    Huijink, R.
    Fujita, H.
    Abelmann, L.
    MEMS 2010: 23RD IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2010, : 328 - 331
  • [48] Design and batch fabrication of probes for sub-100 nm scanning thermal microscopy
    Shi, L
    Kwon, O
    Miner, AC
    Majumdar, A
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2001, 10 (03) : 370 - 378
  • [49] Fabrication and calibration of three temperature probes for monitoring the effects of thermal cancer ablation
    Caponero, M. A.
    Polimadei, A.
    Ariano, M.
    Schena, E.
    Massaroni, C.
    Silvestri, S.
    Saccomandi, P.
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 420 - 424
  • [50] Coupling efficiency of probes in emission-mode scanning near-field optical microscopy
    Alvarez, L.
    Xiao, M.
    JOURNAL OF MICROSCOPY, 2008, 229 (02) : 371 - 376