Axial Load-Moment Interaction Diagram of Circular Concrete Columns Reinforced with CFRP Bars and Spirals: Experimental and Theoretical Investigations

被引:96
|
作者
Hadhood, Abdeldayem [1 ]
Mohamed, Hamdy M. [1 ,2 ]
Benmokrane, Brahim [3 ,4 ,5 ]
机构
[1] Univ Sherbrooke, Dept Civil Engn, Sherbrooke, PQ J1K 2R1, Canada
[2] Helwan Univ, Helwan, Egypt
[3] Univ Sherbrooke, Dept Civil Engn, Civil Engn, 2500 Univ Blvd, Sherbrooke, PQ J1K 2R1, Canada
[4] Univ Sherbrooke, Dept Civil Engn, Adv Composite Mat Civil Struct, 2500 Univ Blvd, Sherbrooke, PQ J1K 2R1, Canada
[5] Univ Sherbrooke, Dept Civil Engn, Innovat FRP Reinforcement Concrete Infrastruct, 2500 Univ Blvd, Sherbrooke, PQ J1K 2R1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Circular; Eccentric loading; Concrete; Column; Carbon fiber-reinforced polymer (CFRP) bars; Carbon fiber-reinforced polymer (CFRP) spirals; Interaction diagram; Sectional analysis;
D O I
10.1061/(ASCE)CC.1943-5614.0000748
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
North America's current design codes and guidelines allow the use of fiber-reinforced polymer (FRP) bars as the primary reinforcement in concrete structures and provide design recommendations for using these bars. Because of a lack of experimental data, however, FRP bars have not been recommended for resisting compression stresses as longitudinal reinforcement in columns or compression reinforcement in flexural elements. This paper presents test results of an experimental program to investigate the structural performance of 10 full-scale circular concrete columns reinforced with carbon fiber-reinforced polymer (CFRP) bars and spirals subjected to combined axial compression loads and bending moments. The test variables include different eccentricity-to-diameter ratios and two types of reinforcement (CFRP and steel). The test results show that the CFRP- and steel-reinforced concrete columns behaved similarly up to their peak loads. The failure of the test specimens under different levels of eccentricity was not triggered by rupture of the CFRP bars in the tension side, but rather it was attributed to gradual concrete crushing, followed by bar crushing on the compression side. Based on the test results, a detailed sectional analysis and plane section analysis were then conducted. Furthermore, a comprehensive parametric investigation was performed to generate numerous nominal axial force-bending moment (P-M) interaction diagrams. The experimental and analytical results are discussed and compared. (C) 2016 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Axial-flexural interaction in circular FRP-confined reinforced concrete columns
    Bisby, Luke
    Ranger, Michael
    CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (09) : 1672 - 1681
  • [42] Experimental analysis on size effect of axial compressive behavior for reinforced concrete columns strengthened with CFRP
    Wang Z.
    Shen S.
    Cui Y.
    Yang J.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2020, 52 (08): : 112 - 120
  • [43] Finite element and theoretical investigations on PVC-CFRP confined concrete columns under axial compression
    Isleem, Haytham F.
    Jagadesh, P.
    Qaidi, Shaker
    Althoey, Fadi
    Rahmawati, Cut
    Najm, Hadee Mohammed
    Sabri, Mohanad Muayad Sabri
    FRONTIERS IN MATERIALS, 2022, 9
  • [44] Behavior of Hollow Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns under Axial Load: Experimental and Theoretical Investigation
    Gouda, Mohammed Gamal
    Mohamed, Hamdy M.
    Manalo, Allan C.
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2022, 119 (06) : 289 - 302
  • [45] Axial load behavior and stability strength of circular tubed steel reinforced concrete (SRC) columns
    Yan, Biao
    Liu, Jiepeng
    Zhou, Xuhong
    STEEL AND COMPOSITE STRUCTURES, 2017, 25 (05): : 545 - 556
  • [46] Structural Behavior of Circular Concrete Columns Reinforced with Longitudinal GFRP Rebars under Axial Load
    Sajedi, Seyed Fathollah
    Saffarian, Iman
    Pourbaba, Masoud
    Yeon, Jung Heum
    BUILDINGS, 2024, 14 (04)
  • [47] Experimental Study on Deformation and Failure of Circular Concrete Columns Reinforced with Glass Fiber-Reinforced Polymer Bars
    Liu, Jun
    Du, Hongkai
    Zhou, Hong
    Nan, Zhiling
    Nie, Pingjun
    ACI STRUCTURAL JOURNAL, 2019, 116 (04) : 45 - 52
  • [48] Experimental study on the behavior of GFRP reinforced concrete columns under eccentric axial load
    Sun, Li
    Wei, Minghai
    Zhang, Na
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 152 : 214 - 225
  • [49] Experimental and numerical investigations of precast circular reinforced concrete slender columns with intermediate connection
    Hamoda, Ahmed
    Ahmed, Mizan
    Abadel, Aref A.
    Gohari, Soheil
    ADVANCES IN STRUCTURAL ENGINEERING, 2024, 27 (03) : 373 - 385
  • [50] Experimental assessment of the effects of biaxial bending moment and axial force on reinforced concrete corner columns
    Dang, Hoang, V
    Lee, Kihak
    Han, Sang W.
    Kim, Sung J.
    STRUCTURAL CONCRETE, 2018, 19 (04) : 1063 - 1078