Axial Load-Moment Interaction Diagram of Circular Concrete Columns Reinforced with CFRP Bars and Spirals: Experimental and Theoretical Investigations

被引:96
|
作者
Hadhood, Abdeldayem [1 ]
Mohamed, Hamdy M. [1 ,2 ]
Benmokrane, Brahim [3 ,4 ,5 ]
机构
[1] Univ Sherbrooke, Dept Civil Engn, Sherbrooke, PQ J1K 2R1, Canada
[2] Helwan Univ, Helwan, Egypt
[3] Univ Sherbrooke, Dept Civil Engn, Civil Engn, 2500 Univ Blvd, Sherbrooke, PQ J1K 2R1, Canada
[4] Univ Sherbrooke, Dept Civil Engn, Adv Composite Mat Civil Struct, 2500 Univ Blvd, Sherbrooke, PQ J1K 2R1, Canada
[5] Univ Sherbrooke, Dept Civil Engn, Innovat FRP Reinforcement Concrete Infrastruct, 2500 Univ Blvd, Sherbrooke, PQ J1K 2R1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Circular; Eccentric loading; Concrete; Column; Carbon fiber-reinforced polymer (CFRP) bars; Carbon fiber-reinforced polymer (CFRP) spirals; Interaction diagram; Sectional analysis;
D O I
10.1061/(ASCE)CC.1943-5614.0000748
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
North America's current design codes and guidelines allow the use of fiber-reinforced polymer (FRP) bars as the primary reinforcement in concrete structures and provide design recommendations for using these bars. Because of a lack of experimental data, however, FRP bars have not been recommended for resisting compression stresses as longitudinal reinforcement in columns or compression reinforcement in flexural elements. This paper presents test results of an experimental program to investigate the structural performance of 10 full-scale circular concrete columns reinforced with carbon fiber-reinforced polymer (CFRP) bars and spirals subjected to combined axial compression loads and bending moments. The test variables include different eccentricity-to-diameter ratios and two types of reinforcement (CFRP and steel). The test results show that the CFRP- and steel-reinforced concrete columns behaved similarly up to their peak loads. The failure of the test specimens under different levels of eccentricity was not triggered by rupture of the CFRP bars in the tension side, but rather it was attributed to gradual concrete crushing, followed by bar crushing on the compression side. Based on the test results, a detailed sectional analysis and plane section analysis were then conducted. Furthermore, a comprehensive parametric investigation was performed to generate numerous nominal axial force-bending moment (P-M) interaction diagrams. The experimental and analytical results are discussed and compared. (C) 2016 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Analytical investigation on the load-moment characteristics of GFRP bar reinforced circular NSC and HSC columns
    Hasan, Hayder Alaa
    Sheikh, M. Neaz
    Hadi, Muhammad N. S.
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 183 : 605 - 617
  • [22] Failure Envelope of Circular Concrete Columns Reinforced with Glass Fiber-Reinforced Polymer Bars and Spirals
    Hadhood, Abdeldayem
    Mohamed, Hamdy M.
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2017, 114 (06) : 1417 - 1428
  • [23] Numerical evaluation of axial compressive behavior of hollow concrete columns reinforced with GFRP bars and spirals
    Tahir, Muhammad
    Karam, Muhammad Shoaib
    Hassam, Muhammad
    Umer, Muhammad
    Hameed, Rashid
    STRUCTURAL CONCRETE, 2024, 25 (01) : 566 - 582
  • [24] Axial performance of hybrid fiber reinforced concrete columns having GFRP longitudinal bars and spirals
    Raza, Ali
    Ali, Babar
    Aslam, Hafiz Muhammad Usman
    JOURNAL OF BUILDING ENGINEERING, 2021, 35
  • [25] Compressive behavior of axially loaded circular hollow concrete columns reinforced with GFRP bars and spirals
    AlAjarmeh, O. S.
    Manalo, A. C.
    Benmokrane, B.
    Karunasena, W.
    Mendis, P.
    Nguyen, K. T. Q.
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 194 : 12 - 23
  • [26] Experimental assessment and theoretical evaluation of axial behavior of short and slender CFFT columns reinforced with steel and CFRP bars
    Abdallah, Maha Hussein
    Mohamed, Hamdy M.
    Masmoudi, Radhouane
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 181 : 535 - 550
  • [27] Experimental Investigations on Circular Concrete Columns Reinforced with GFRP Bars and Helices under Different Loading Conditions
    Hadi, Muhammad N. S.
    Karim, Hogr
    Sheikh, M. Neaz
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (04)
  • [28] Experimental Study of Circular High-Strength Concrete Columns Reinforced with GFRP Bars and Spirals under Concentric and Eccentric Loading
    Hadhood, Abdeldayem
    Mohamed, Hamdy M.
    Benmokrane, Brahim
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2017, 21 (02)
  • [29] Experimental study and theoretical analysis on axial compressive behavior of concrete columns reinforced with GFRP bars and PVA fibers
    Zhang, Xiuli
    Deng, Zongcai
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 172 : 519 - 532
  • [30] Axial compressive behavior of damaged steel and GFRP bars reinforced concrete columns retrofitted with CFRP laminates
    Aslam, Hafiz Muhammad Usman
    Khan, Qaiser Uz Zaman
    Sami, Abdul
    Raza, Ali
    COMPOSITE STRUCTURES, 2021, 258