An extended radon chamber model

被引:0
|
作者
ButterweckDempewolf, G
Schuler, C
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The radon chamber model developed at the Paul Scherrer Institut (PSI) is covering differences in size between the different short-lived radon daughters by taking into account nuclide specific deposition and attachment rates. The resulting set of differential equations was analytically solved and the solutions were installed into a computer code. Different modes of operation of a radon chamber (continuous flow, pulse, and feedback) were analysed with the model. The influence of aerosol sampling on the chamber atmosphere was studied. Increasing the diffusion constant of the radon daughter clusters increases both attachment and deposition rates. As a consequence, the unattached concentration of the radon daughter with the shortest half-life, Po-218, is reduced relative to the radon progeny Pb-214 and Bi-214/Po-214, compared with calculations with equal mobilities of the radon progeny. The amount of Po-218 activity deposited on the chamber walls also is increased relative to the other radon progeny if the size of Po-218 is considered to be smaller. Copyright 1996 Elsevier Science Ltd.
引用
收藏
页码:S891 / S898
页数:8
相关论文
共 50 条
  • [21] RADON CHAMBER FOR CALIBRATION OF CHARCOAL DETECTORS
    COHEN, BL
    NASON, R
    HEALTH PHYSICS, 1986, 51 (01): : 135 - 137
  • [22] A reference aerosol for a radon reference chamber
    Paul, A
    Keyser, U
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 368 (03): : 819 - 824
  • [23] A reference aerosol for a radon reference chamber
    Paul, Annette
    Keyser, Uwe
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 368 (03): : 819 - 824
  • [24] RADON REGISTRATION WITH AN ELECTRET DIFFUSION CHAMBER
    PRETZSCH, G
    BORNER, E
    LEHMANN, R
    SARENIO, O
    RADIATION PROTECTION DOSIMETRY, 1987, 18 (02) : 75 - 80
  • [25] Reference aerosol for a radon reference chamber
    Paul, A.
    Keyser, U.
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 368 (03):
  • [26] Development of radon calibration chamber at KRISS
    Lee, JM
    Ahn, KH
    Chai, HS
    Park, TS
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (2-3) : 237 - 241
  • [27] AN INTEGRATING CONCENTRATION RADON CALIBRATION CHAMBER
    PANG, DL
    ZHOU, ZX
    LI, LD
    ZHU, B
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 423 - 425
  • [28] Monitoring and measurement of radon activity in a new design of radon calibration chamber
    Heidary, S.
    Setayeshi, S.
    Ghannadi-Maragheh, M.
    Negarestani, A.
    RADIATION MEASUREMENTS, 2011, 46 (08) : 694 - 700
  • [29] Performance test for radon measuring instruments using radon chamber at PTB
    Sorimachi, Atsuyuki
    Ishikawa, Tetsuo
    Tokonami, Shinji
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (06) : 994 - 998
  • [30] APPLICATIONS OF THE DOE/GJPO RADON/RADON-DAUGHTER ENVIRONMENTAL CHAMBER
    PEARSON, MD