The radon chamber model developed at the Paul Scherrer Institut (PSI) is covering differences in size between the different short-lived radon daughters by taking into account nuclide specific deposition and attachment rates. The resulting set of differential equations was analytically solved and the solutions were installed into a computer code. Different modes of operation of a radon chamber (continuous flow, pulse, and feedback) were analysed with the model. The influence of aerosol sampling on the chamber atmosphere was studied. Increasing the diffusion constant of the radon daughter clusters increases both attachment and deposition rates. As a consequence, the unattached concentration of the radon daughter with the shortest half-life, Po-218, is reduced relative to the radon progeny Pb-214 and Bi-214/Po-214, compared with calculations with equal mobilities of the radon progeny. The amount of Po-218 activity deposited on the chamber walls also is increased relative to the other radon progeny if the size of Po-218 is considered to be smaller. Copyright 1996 Elsevier Science Ltd.
引用
收藏
页码:S891 / S898
页数:8
相关论文
共 50 条
  • [1] The development of radon chamber based on dynamic replenishment model
    Zhou Shumin
    Sun Yamin
    Lu Ling
    Gao Yongping
    SIGNAL ANALYSIS, MEASUREMENT THEORY, PHOTO-ELECTRONIC TECHNOLOGY, AND ARTIFICIAL INTELLIGENCE, PTS 1 AND 2, 2006, 6357
  • [2] Control of radon concentrations in a radon chamber
    Chen, CJ
    Liu, CC
    Lin, YM
    RADON AND THORON IN THE HUMAN ENVIRONMENT, 1998, : 50 - 55
  • [3] Measurement of radon and radon progenies at the German radon reference chamber
    Paul, A
    Honig, A
    Röttger, S
    Keyser, U
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (03) : 369 - 375
  • [4] Radon kinetics in a natural indoor radon chamber
    Chung, Long Kiu
    Mata, Loren A.
    Carmona, Marco A.
    Shubayr, Nasser Ali M.
    Zhou, Qingzhi
    Ye, Yongjun
    Kearfott, Kimberlee J.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 734 (734)
  • [5] Evaluation of the uniformity of concentration of radon in a radon chamber
    Zhang Xiongjie
    Zhang Ye
    Liu Yang
    Tang Bin
    APPLIED RADIATION AND ISOTOPES, 2016, 110 : 183 - 188
  • [6] Radon concentration control system of radon chamber
    Radon Laboratory, Nanhua University, Hengyang 421001, China
    He Jishu, 2007, 6 (553-556):
  • [7] Hereditary Mathematical Model of the Dynamics of Radon Accumulation in the Accumulation Chamber
    Tverdyi, Dmitrii
    Makarov, Evgeny
    Parovik, Roman
    MATHEMATICS, 2023, 11 (04)
  • [8] RADON CHAMBER FOR BIOLOGICAL TREATMENT
    TAVERA, L
    BALCAZAR, M
    VILLALOBOSPIETRINI, R
    DELAROSA, ME
    BRENA, M
    CAMACHO, ME
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 469 - 474
  • [9] CALIBRATION OF RADON GAS MONITORS USING AN ENVIRONMENTAL RADON CHAMBER
    HALL, JB
    HEALTH PHYSICS, 1985, 49 (01): : 156 - 156
  • [10] A new method for evaluating the stability of radon concentration in a radon chamber
    Feng, Yangyang
    Zhang, Xiongjie
    Zhang, Yan
    Zhang, Ye
    Tian, Xingyu
    Huang, Rengui
    Cao, Jie
    Tang, Bin
    JOURNAL OF INSTRUMENTATION, 2023, 18 (07)