Development and validation of a measurement system for continuously monitoring postoperative reservoir levels

被引:1
|
作者
Eichhorn, S. [1 ,2 ]
Reisinger, T. [1 ,2 ]
Boehm, J. [1 ,2 ]
Voss, S. [1 ,2 ]
Doppler, S. [1 ,2 ]
Lange, R. [1 ,2 ,3 ]
Krane, M. [1 ,2 ,3 ]
机构
[1] Tech Univ Munich, German Heart Ctr Munich, Dept Cardiovasc Surg, Lazarettstr 36, D-80636 Munich, Germany
[2] Tech Univ Munich, INSURE Inst Translat Cardiac Surg, Dept Cardiovasc Surg, Lothstr 11, D-80636 Munich, Germany
[3] DZHK German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, D-80636 Munich, Germany
关键词
Postoperative monitoring; Surgical reservoir; Measurement system; CARDIAC-SURGERY; BLOOD; RISK; REEXPLORATION; TRANSFUSION;
D O I
10.1007/s13246-019-00746-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Following cardiac surgical procedures, multiple drainage systems remain in place inside the patient's chest to prevent the development of pericardial effusion or pneumothorax. Therefore, postoperative bleeding must be diligently observed. Currently, observation of the exudate rate is performed through periodical visual inspection of the reservoir. To improve postoperative monitoring, a measurement system based on load cells was developed to automatically detect bleeding rates. A reservoir retaining bracket was instrumented with a load cell. The signal was digitized by a microcontroller and then processed and displayed on customized software written in LabView. In cases where bleeding rates reach critical levels, the device will automatically sound an alarm. Additionally, the bleeding rate is displayed on the screen with the status of the alarm, as well as the fluid level of the reservoir. These data are all logged to a file. The measurement system has been validated for gain stability and drift, as well as for sensor accuracy, with different in vitro examinations. Additionally, performance of the measurement device was tested in a clinical pilot study on patients recovering from cardiac surgical procedures. The in vitro investigation showed that the monitoring device had excellent gain and drift stability, as well as sensor accuracy, with a resolution of 2.6mL/h for the bleeding rate. During the clinical examination, bleeding rates of all patients were correctly measured. Continuously recording drainage volume using the developed system was comparable to manual measurements performed every 30min by a nurse. Implementation of continuous digital measurements could improve patient safety and reduce the workload of medical professionals working in intensive care units.
引用
收藏
页码:611 / 617
页数:7
相关论文
共 50 条
  • [41] Development of a Portable Linux-Based ECG Measurement and Monitoring System
    Tan, Tan-Hsu
    Chang, Ching-Su
    Huang, Yung-Fa
    Chen, Yung-Fu
    Lee, Cheng
    JOURNAL OF MEDICAL SYSTEMS, 2011, 35 (04) : 559 - 569
  • [42] Design and Development of a Monitoring System for the Interface Pressure Measurement of Seated People
    Marenzi, Elisa
    Bertolotti, Gian Mario
    Cristiani, Andrea
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (03) : 570 - 577
  • [43] Development of temperature monitoring and dielectric spectrum measurement system based on LabVIEW
    Huang, Yonghong
    Wang, Henghai
    Chen, Zhaozhang
    Xu, Xiaobin
    Qi, Dongming
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2008, 29 (07): : 1544 - 1547
  • [44] A SYSTEM FOR CONTINUOUSLY MONITORING OLEORESIN EXUDATION PRESSURE IN SLASH PINE
    HELSETH, FA
    BROWN, CL
    FOREST SCIENCE, 1970, 16 (03) : 346 - &
  • [45] Electronic triage system for continuously monitoring casualties at disaster scenes
    Keishi Sakanushi
    Takuji Hieda
    Taichiro Shiraishi
    Yasumasa Ode
    Yoshinori Takeuchi
    Masaharu Imai
    Teruo Higashino
    Hiroshi Tanaka
    Journal of Ambient Intelligence and Humanized Computing, 2013, 4 : 547 - 558
  • [46] Development and Validation of a Portable EIT System for Real-Time Respiratory Monitoring
    Alvarado-Arriagada, Fabian
    Fernandez-Arroyo, Bruno
    Rebolledo, Samuel
    Pino, Esteban J.
    SENSORS, 2024, 24 (20)
  • [47] Measurement and validation of PbS nanocrystal energy levels
    Dissanayake, D. M. N. M.
    Lutz, T.
    Curry, R. J.
    Silva, S. R. P.
    APPLIED PHYSICS LETTERS, 2008, 93 (04)
  • [48] Reservoir fisheries governance quality index: Development and validation
    Katre, Nidhi
    Sharma, Arpita
    Ojha, S. N.
    Tyagi, Lalit
    Yadav, Vinod
    ECOLOGICAL INDICATORS, 2024, 158
  • [49] Validation of a bioassay for the measurement of voriconazole levels in serum
    Vyzantiadis, T. A.
    Vyzantiadis, T. A.
    Ioakimidou, A.
    Kotsinou, S.
    Malissiovas, N.
    MYCOSES, 2011, 54 : 136 - 136
  • [50] Electronic triage system for continuously monitoring casualties at disaster scenes
    Sakanushi, Keishi
    Hieda, Takuji
    Shiraishi, Taichiro
    Ode, Yasumasa
    Takeuchi, Yoshinori
    Imai, Masaharu
    Higashino, Teruo
    Tanaka, Hiroshi
    JOURNAL OF AMBIENT INTELLIGENCE AND HUMANIZED COMPUTING, 2013, 4 (05) : 547 - 558