Comparison of chest compression quality between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method during CPR

被引:10
|
作者
Park, Sang-Sub [1 ,2 ]
机构
[1] ChungCheong Univ, Dept Emergency Med Technol, Cheongju, South Korea
[2] Korea Univ, Grad Sch Pharm, Jochiwon Eup 339700, Sejong Si, South Korea
关键词
Cardiopulmonary resuscitation; smartphone; application; chest compression; CARDIOPULMONARY-RESUSCITATION; DECOMPRESSION;
D O I
10.3233/THC-140791
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The purpose of this study is to grasp difference in quality of chest compression accuracy between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method. Participants were progressed 64 people except 6 absentees among 70 people who agreed to participation with completing the CPR curriculum. In the classification of group in participants, the modified chest compression method was called as smartphone group (33 people). The standardized chest compression method was called as traditional group (31 people). The common equipments in both groups were used Manikin for practice and Manikin for evaluation. In the meantime, the smartphone group for application was utilized Android and iOS Operating System (OS) of 2 smartphone products (G, i). The measurement period was conducted from September 25th to 26th, 2012. Data analysis was used SPSS WIN 12.0 program. As a result of research, the proper compression depth (mm) was shown the proper compression depth (p < 0.01) in traditional group (53.77 mm) compared to smartphone group (48.35 mm). Even the proper chest compression (%) was formed suitably (p < 0.05) in traditional group (73.96%) more than smartphone group (60.51%). As for the awareness of chest compression accuracy, the traditional group (3.83 points) had the higher awareness of chest compression accuracy (p < 0.001) than the smartphone group (2.32 points). In the questionnaire that was additionally carried out 1 question only in smartphone group, the modified chest compression method with the use of smartphone had the high negative reason in rescuer for occurrence of hand back pain (48.5%) and unstable posture (21.2%).
引用
收藏
页码:351 / 358
页数:8
相关论文
共 50 条
  • [31] The suprasternal notch as a landmark of chest compression depth in CPR
    Kim, Tae Hu
    Lee, Soo Hoon
    Kim, Dong Hoon
    Lee, Ryun Kyung
    Kim, So Yeon
    Kang, Changwoo
    Jeong, Jin Hee
    Kim, Seong Chun
    Lee, Sang Bong
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (03): : 433 - 436
  • [32] Sex Disparities in Chest Compression Quality
    Retzer, Elizabeth
    Yuen, Trevor C.
    Cua, Jefferson L.
    Edelson, Dana P.
    CIRCULATION, 2011, 124 (21)
  • [33] Chest compression-only CPR Is it the better choice?
    Koster, R. W.
    NOTFALL & RETTUNGSMEDIZIN, 2012, 15 (06): : 482 - 485
  • [34] Comparison of Chest Compression Quality Between the Floor and the Bed Using Backboard
    Jang, J.
    Park, T.
    Lee, D.
    Lee, S.
    Kim, S.
    Kim, C.
    ANNALS OF EMERGENCY MEDICINE, 2009, 54 (03) : S139 - S139
  • [35] Identification of an optimal CPR chest compression protocol.
    Daudre-Vignier, C.
    Laviola, M.
    Das, A.
    Bates, D. G.
    Hardman, J. G.
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 5459 - 5462
  • [36] CPR with Chest Compression Alone or with Rescue Breathing.
    Rea, Thomas D.
    Fahrenbruch, Carol
    Culley, Linda
    Donohoe, Rachael T.
    Hambly, Cindy
    Innes, Jennifer
    Bloomingdale, Megan
    Subido, Cleo
    Romines, Steven
    Eisenberg, Mickey S.
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (05): : 423 - 433
  • [37] Effects of variable depth of chest compression on outcomes of CPR
    Ristagno, Giuseppe
    Tang, Wanchun
    Jorgensen, Dawn
    Russell, James K.
    Wang, Tong
    Sun, Shijie
    Weil, Max H.
    CIRCULATION, 2006, 114 (18) : 1205 - 1206
  • [38] Chest-compression-only versus standard CPR
    Rea, Tom
    Bobrow, Bentley
    Spaite, Daniel
    LANCET, 2011, 377 (9767): : 717 - 717
  • [39] Mechanical chest compression with the LifeLine ARM device during simulated CPR
    Truszewski, Zenon
    Szarpak, Lukasz
    Kurowski, Andrzej
    Evrin, Togay
    Madziala, Marcin
    Czyzewski, Lukasz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (05): : 917 - 917
  • [40] Hemodynamic function during CPR: Effect of chest compression time and rate
    Hevesi, Z
    Thrush, DN
    Downs, JB
    Smith, RA
    CRITICAL CARE MEDICINE, 1999, 27 (01) : A83 - A83