Comparison of chest compression quality between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method during CPR

被引:10
|
作者
Park, Sang-Sub [1 ,2 ]
机构
[1] ChungCheong Univ, Dept Emergency Med Technol, Cheongju, South Korea
[2] Korea Univ, Grad Sch Pharm, Jochiwon Eup 339700, Sejong Si, South Korea
关键词
Cardiopulmonary resuscitation; smartphone; application; chest compression; CARDIOPULMONARY-RESUSCITATION; DECOMPRESSION;
D O I
10.3233/THC-140791
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The purpose of this study is to grasp difference in quality of chest compression accuracy between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method. Participants were progressed 64 people except 6 absentees among 70 people who agreed to participation with completing the CPR curriculum. In the classification of group in participants, the modified chest compression method was called as smartphone group (33 people). The standardized chest compression method was called as traditional group (31 people). The common equipments in both groups were used Manikin for practice and Manikin for evaluation. In the meantime, the smartphone group for application was utilized Android and iOS Operating System (OS) of 2 smartphone products (G, i). The measurement period was conducted from September 25th to 26th, 2012. Data analysis was used SPSS WIN 12.0 program. As a result of research, the proper compression depth (mm) was shown the proper compression depth (p < 0.01) in traditional group (53.77 mm) compared to smartphone group (48.35 mm). Even the proper chest compression (%) was formed suitably (p < 0.05) in traditional group (73.96%) more than smartphone group (60.51%). As for the awareness of chest compression accuracy, the traditional group (3.83 points) had the higher awareness of chest compression accuracy (p < 0.001) than the smartphone group (2.32 points). In the questionnaire that was additionally carried out 1 question only in smartphone group, the modified chest compression method with the use of smartphone had the high negative reason in rescuer for occurrence of hand back pain (48.5%) and unstable posture (21.2%).
引用
收藏
页码:351 / 358
页数:8
相关论文
共 50 条
  • [21] Impact of Resting Between Cycles on CPR Chest Compression Performance
    Curran, Robert
    Doshi, Krupa
    Dunbar, Christopher C.
    CIRCULATION, 2010, 122 (21)
  • [22] The use of a backboard during cardiopulmonary resuscitation and chest compression quality
    Houthoofdt, Ruben
    Cuvelier, Zara
    Serraes, Brecht
    Haentjens, Carl
    Mpotos, Nicolas
    Blot, Stijn
    AUSTRALIAN CRITICAL CARE, 2023, 36 (02) : 172 - 173
  • [23] Chest Compression Depth and Rate - Effect on Instructor Visual Assessment of Chest Compression Quality -
    Nagafuchi, Katsuya
    Hifumi, Toru
    Nishimoto, Naoki
    Kondo, Yutaka
    Yoshikawa, Kei
    Iwami, Taku
    Kuroda, Yasuhiro
    CIRCULATION JOURNAL, 2019, 83 (02) : 418 - +
  • [24] Use of an automated chest compression device during CPR in our cath lab
    Koufakis, N.
    Gata, V.
    Theodorakopoulou, A.
    Stasinopoulou, A.
    Antoniadou, F.
    Biliardis, C. H.
    Kazantza, G.
    Latsios, G.
    Tousoulis, D.
    EUROPEAN JOURNAL OF CARDIOVASCULAR NURSING, 2016, 15 : S91 - S91
  • [25] Why Traditional Chest Compression Is Not Adequate For Most Lone-Rescuer CPR Situations, and Whether There Is A Method That Is
    Perez, Fernando J.
    Trenkamp, Robert H., Jr.
    CIRCULATION, 2012, 126 (23) : 2798 - 2798
  • [26] A New Chest Compression Depth Feedback Algorithm for High-Quality CPR Based on Smartphone
    Song, Yeongtak
    Oh, Jaehoon
    Chee, Youngjoon
    TELEMEDICINE AND E-HEALTH, 2015, 21 (01) : 36 - 41
  • [27] Chest compression-only CPR or good quality 30:2 CPR
    Anantharaman, V
    SINGAPORE MEDICAL JOURNAL, 2011, 52 (08) : 576 - 581
  • [28] Chest compression quality and rescuer fatigue with increased compression to ventilation ratio during single rescuer pediatric CPR
    Haque, Ikram U.
    Udassi, Jai P.
    Udassi, Sharda
    Theriaque, Douglas W.
    Shuster, Jonathan J.
    Zaritsky, Arno L.
    RESUSCITATION, 2008, 79 (01) : 82 - 89
  • [29] Chest compression quality and patient outcomes with the use of a CPR feedback device: A retrospective study
    Wen Zhe Leo
    Damien Chua
    Hui Cheng Tan
    Vui Kian Ho
    Scientific Reports, 13
  • [30] Chest compression quality and patient outcomes with the use of a CPR feedback device: A retrospective study
    Leo, Wen Zhe
    Chua, Damien
    Tan, Hui Cheng
    Ho, Vui Kian
    SCIENTIFIC REPORTS, 2023, 13 (01)