Comparison of chest compression quality between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method during CPR

被引:10
|
作者
Park, Sang-Sub [1 ,2 ]
机构
[1] ChungCheong Univ, Dept Emergency Med Technol, Cheongju, South Korea
[2] Korea Univ, Grad Sch Pharm, Jochiwon Eup 339700, Sejong Si, South Korea
关键词
Cardiopulmonary resuscitation; smartphone; application; chest compression; CARDIOPULMONARY-RESUSCITATION; DECOMPRESSION;
D O I
10.3233/THC-140791
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The purpose of this study is to grasp difference in quality of chest compression accuracy between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method. Participants were progressed 64 people except 6 absentees among 70 people who agreed to participation with completing the CPR curriculum. In the classification of group in participants, the modified chest compression method was called as smartphone group (33 people). The standardized chest compression method was called as traditional group (31 people). The common equipments in both groups were used Manikin for practice and Manikin for evaluation. In the meantime, the smartphone group for application was utilized Android and iOS Operating System (OS) of 2 smartphone products (G, i). The measurement period was conducted from September 25th to 26th, 2012. Data analysis was used SPSS WIN 12.0 program. As a result of research, the proper compression depth (mm) was shown the proper compression depth (p < 0.01) in traditional group (53.77 mm) compared to smartphone group (48.35 mm). Even the proper chest compression (%) was formed suitably (p < 0.05) in traditional group (73.96%) more than smartphone group (60.51%). As for the awareness of chest compression accuracy, the traditional group (3.83 points) had the higher awareness of chest compression accuracy (p < 0.001) than the smartphone group (2.32 points). In the questionnaire that was additionally carried out 1 question only in smartphone group, the modified chest compression method with the use of smartphone had the high negative reason in rescuer for occurrence of hand back pain (48.5%) and unstable posture (21.2%).
引用
收藏
页码:351 / 358
页数:8
相关论文
共 50 条
  • [1] Quality of chest compressions during continuous CPR; comparison between chest compression-only CPR and conventional CPR
    Nishiyama, Chika
    Iwami, Taku
    Kawamura, Takashi
    Ando, Masahiko
    Yonemoto, Naohiro
    Hiraide, Atsushi
    Nonogi, Hiroshi
    RESUSCITATION, 2010, 81 (09) : 1152 - 1155
  • [2] QUALITY COMPARISON OF THE MANUAL CHEST COMPRESSION AND THE MECHANICAL CHEST COMPRESSION DURING DIFFICULT TRANSPORT CONDITIONS
    Bekgoz, Burak
    San, Ishak
    Ergin, Mehmet
    JOURNAL OF EMERGENCY MEDICINE, 2020, 58 (03): : 432 - 438
  • [3] Optimal chest compression for CPR
    Tim Geach
    Nature Reviews Cardiology, 2014, 11 (12) : 687 - 687
  • [4] Comparison of CPR outcome predictors between rhythmic abdominal compression and continuous chest compression CPR techniques
    Kammeyer, Ryan M.
    Pargett, Michael S.
    Rundell, Ann E.
    EMERGENCY MEDICINE JOURNAL, 2014, 31 (05) : 394 - 400
  • [5] Chest compression performance is better with chest compression-only than standard CPR
    Heidenreich, JW
    Higdon, TA
    Sanders, AB
    Kern, KB
    Berg, RA
    Ewy, GA
    CIRCULATION, 2002, 106 (19) : 663 - 664
  • [6] Poster: Depth and Rate Estimation for Chest Compression CPR with Smartphone
    Amemiya, Tomohiro
    Maeda, Taro
    2013 IEEE SYMPOSIUM ON 3D USER INTERFACES (3DUI), 2013, : 125 - 126
  • [7] Comparison between mechanical active chest compression/decompression and standard mechanical chest compression
    Ristagno, Giuseppe
    Tang, Wanchun
    Wang, Hao
    Sun, Shijie
    Weil, Max H.
    CIRCULATION, 2007, 116 (16) : 929 - 930
  • [8] THE EFFECT OF PIT CREW CPR ON THE QUALITY OF CHEST COMPRESSION
    Xiao, Wenyan
    Hua, Tianfeng
    Yang, Min
    CRITICAL CARE MEDICINE, 2022, 50 (01) : 687 - 687
  • [9] MAINTENANCE OF CIRCULATION WITHOUT CHEST COMPRESSION DURING CPR
    PASSERINI, L
    WISE, RA
    ROUSSOS, C
    MAGDER, S
    JOURNAL OF CRITICAL CARE, 1988, 3 (02) : 96 - 102
  • [10] Influence of lay rescuers age on quality of chest compression and fatigue during continuous chest compression (UCPR) and conventional cardiopulmonary resuscitation (CPR)
    Reus, E.
    Idris, K.
    Sengewald, U.
    Schmidt, D.
    Grundmann, U.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 191 - 191