Quantification of bone microstructure in the wrist using cone-beam computed tomography

被引:26
|
作者
Mys, Karen [1 ]
Stockmans, Filip [2 ]
Vereecke, Evie [2 ]
van Lenthe, G. Harry [1 ]
机构
[1] Katholieke Univ Leuven, Dept Mech Engn, Biomech Sect, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Dev & Regenerat, Muscles & Movement, Campus Kulak, Kortrijk, Belgium
关键词
Cone-beam computed tomography; Bone parameters; Micro-computed tomography; Medical imaging processing; Quantification; RESOLUTION; CT; ACCURACY; MICROARCHITECTURE;
D O I
10.1016/j.bone.2018.06.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Due to the rising life expectancy, bone diseases (e g osteoporosis, osteoarthritis) and trauma (e.g. fracture) have become an important socio-economic burden Accurate visualization and quantification of the bone micro structure in vivo is seen as an important step to enhance diagnosis and treatment. Micro-computed tomography (microCT) has become the gold standard in three-dimensional (3D) imaging of trabecular bone structure. Yet, usage is limited to ex vivo analyses, hence, it cannot be used to evaluate bone and bone adaptive responses in a patient High-resolution peripheral computed tomography (HR-pQCT) is considered the best technique to measure the bone microarchitecture in vivo By design HR pQCT is limited to scanning extremities, such as the distal radius and distal tibia with a limited field of view and long scanning time (similar to 2a 3 mm for a stack of 0.9 cm). Cone-beam computed tomography (CBCT) is a promising alternative with a much larger field of view. Yet, CBCT is challenged by artefacts that reduce image contrast, such that it is currently being used for qualitative evaluation only. Therefore, the aims of this work were first to enhance image contrast and second to determine the accuracy of high-resolution CBCT for bone microarchitectural assessment. Trapezia of nineteen female arthritic patients were scanned twice ex vivo, once using CBCT (NewTom 5G, Cefla, Verona, Italy) at a nominal voxel size of 75 mu m and once using microCT (SkyScan 1172, Bruker, Kontich, Belgium) at a voxel size of 19 84 mu m. The CBCT-scans were reconstructed following 2 protocols: (1) using the commercial software delivered with the scanner and (2) using in-house developed software After reconstruction and image processing, the images were segmented using adaptive thresholding Bone morphometry parameters including bone volume (BV), total tissue volume (TV), bone volume fraction (BV/TV), bone surface density (BS/ TV), trabecular thickness (Tb.Th), trabecular separation (Tb Sp) and trabecular number (Tb N) were calculated Statistical evaluations were made at a significance level of 5%. Significant correlations were found between the CBCT based bone parameters and the microCT based parameters with R-2 > 0.68 The in house reconstructed software outperformed the commercial software. Smaller bias (overestimation of TbTh decreased from 114.24% to 59.96%) as well as higher correlations were observed for the in-house processed images. Still, a significant overestimation was observed for BV/TV and Tb. Th and an underestimation for Tb.N. We conclude that our CBCT image reconstruction improved image contrast which allowed for an accurate quantification of trabecular bone microarchitecture.
引用
收藏
页码:206 / 214
页数:9
相关论文
共 50 条
  • [31] Evaluation and New Classification of Alveolar Bone Dehiscences Using Cone-beam Computed Tomography in vivo
    Yang, Yan
    Yang, Hui
    Pan, Hongyin
    Xu, Jue
    Hu, Tao
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2015, 33 (01): : 361 - 368
  • [32] Cone-Beam Computed Tomography (CBCT) to Computed Tomography (CT) Image Translation with Perceptual Loss to Eliminate Cone-Beam Artifacts
    Yoo, S.
    Choi, B.
    Park, I.
    Kim, J.
    Kim, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [33] Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography
    Rong-Ting He
    Ming-Gene Tu
    Heng-Li Huang
    Ming-Tzu Tsai
    Jay Wu
    Jui-Ting Hsu
    BMC Medical Imaging, 19
  • [34] Classification of alveolar bone destruction patterns on maxillary molars by using cone-beam computed tomography
    Ozcan, G.
    Sekerci, A. E.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2017, 20 (08) : 1010 - 1019
  • [35] ASSESSMENT OF BUCCAL BONE THICKNESS IN THE MAXILLARY AND MANDIBULAR CANINE USING CONE-BEAM COMPUTED TOMOGRAPHY
    Almahdi, Rahmah Abdullah
    Alasqah, Mohammed
    INTERNATIONAL JOURNAL OF MEDICAL DENTISTRY, 2021, 25 (03) : 331 - 338
  • [36] Mandibular Cortical Bone Index Using Multi-Slice and Cone-Beam Computed Tomography
    Naitoh, Munetaka
    Takada, Shoko Tamaki
    Watanabe, Hirofumi
    Hayashi, Hisashi
    Miyamae, Shin
    Ariji, Eiichiro
    JOURNAL OF HARD TISSUE BIOLOGY, 2016, 25 (03) : 241 - 246
  • [37] Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography
    He, Rong-Ting
    Tu, Ming-Gene
    Huang, Heng-Li
    Tsai, Ming-Tzu
    Wu, Jay
    Hsu, Jui-Ting
    BMC MEDICAL IMAGING, 2019, 19 (1)
  • [38] Percutaneous screw fixation of pelvic bone metastases using cone-beam computed tomography navigation
    Cornelis, Francois H.
    Razakamanantsoa, Leo
    Ben Ammar, Mohamed
    Najdawi, Milan
    El-Mouhadi, Sanaa
    Gardavaud, Francois
    Barral, Matthias
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (7-8) : 367 - 374
  • [39] Accuracy of cone-beam computed tomography in detecting alveolar bone dehiscences and fenestrations
    Sun, Liangyan
    Zhang, Lina
    Shen, Guofang
    Wang, Bo
    Fang, Bing
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 147 (03) : 313 - 323
  • [40] Cone-beam computed tomography arthrography: an innovative modality for the evaluation of wrist ligament and cartilage injuries
    Reeta Ramdhian-Wihlm
    Jean-Marie Le Minor
    Matthieu Schmittbuhl
    Jeremy Jeantroux
    Peter Mac Mahon
    Francis Veillon
    Jean-Claude Dosch
    Jean-Louis Dietemann
    Guillaume Bierry
    Skeletal Radiology, 2012, 41 : 963 - 969