Estimating motor unit discharge patterns from high-density surface electromyogram

被引:215
|
作者
Holobar, Ales [1 ,2 ]
Farina, Dario [3 ]
Gazzoni, Marco [1 ]
Merletti, Roberto [1 ]
Zazula, Damjan [2 ]
机构
[1] Politecn Torino, Lab Ingn Sistema Neuromuscolare, Dipartimento Elettron, I-10129 Turin, Italy
[2] Univ Maribor, Fac Elect Engn & Comp Sci, SLO-2000 Maribor, Slovenia
[3] Aalborg Univ, Ctr Sensory Motor Interact SMI, Dept Hlth Sci & Technol, Aalborg, Denmark
关键词
Motor unit; Discharge pattern; High-density EMG; Surface EMG; Decomposition; CONDUCTION-VELOCITY; AMPLITUDE CANCELLATION; ACTION-POTENTIALS; NORMATIVE DATA; EMG; DECOMPOSITION; MUSCLE; RECRUITMENT; SIZE; SEPARATION;
D O I
10.1016/j.clinph.2008.10.160
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: We systematically tested the capability of the Convolution Kernel Compensation (CKC) method to identify motor unit (MU) discharge patterns from the simulated and experimental surface electromyogram (sEMG) during low-force contractions. Methods- sEMG was detected with a grid of 13 x 5 electrodes. In simulated signals with 20 dB signal-to-noise ratio, 11 +/- 3 out of 63 concurrently active MUs were identified with sensitivity >95% in the estimation of their discharge times. In experimental signals recorded at 0-10% of the maximal force, the discharge partterns of(range) 11-19 MUs (abductor pollicis; n = 8 subjects), 9-17 MUs (biceps brachii; n = 2), 7-11 MUs (upper trapezius: n = 2), and 6-10 MUs(vastus lateralis: n = 2) were identified. In the abductor digiti minimi muscle of one subject, the decomposition results from concurrently recorded sEMG and intramuscular EMG (iEMG) were compared; the two approaches agreed on 98 +/- 1% of-MU discharges. Conclusion: It is possible to identify the discharge patterns of several MUs during low-force contractions From high-density sEMG. Significance: sEMG call be used for the analysis of individual MUs when the application of needles is not desirable or in combination with iEMG to increase the number or sampled MUs. (C) 2009 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:551 / 562
页数:12
相关论文
共 50 条
  • [1] Identification of Motor Unit Discharge Patterns from High-Density Surface EMG during High Contraction Levels
    Holobar, A.
    Minetto, M. A.
    Botter, A.
    Farina, D.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 1165 - +
  • [2] Estimating reflex responses in large populations of motor units by decomposition of the high-density surface electromyogram
    Yavuz, Utku S.
    Negro, Francesco
    Sebik, Oguz
    Holobar, Ales
    Froemmel, Cornelius
    Turker, Kemal S.
    Farina, Dario
    JOURNAL OF PHYSIOLOGY-LONDON, 2015, 593 (19): : 4305 - 4318
  • [3] Motor Unit Identification in the M Waves Recorded by High-Density Electromyogram
    Kalc, Milos
    Skarabot, Jakob
    Divjak, Matjaz
    Urh, Filip
    Kramberger, Matej
    Vogrin, Matjaz
    Holobar, Ales
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (05) : 1662 - 1672
  • [4] Tutorial: Analysis of motor unit discharge characteristics from high-density surface EMG signals
    Del Vecchio, A.
    Holobar, A.
    Falla, D.
    Felici, F.
    Enoka, R. M.
    Farina, D.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2020, 53
  • [5] Motor unit tracking with high-density surface EMG
    Maathuis, Ellen M.
    Drenthen, Judith
    van Dijk, Johannes P.
    Visser, Gerhard H.
    Blok, Joleen H.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (06) : 920 - 930
  • [6] Accurate identification of motor unit discharge patterns from high-density surface EMG and validation with a novel signal-based performance metric
    Holobar, A.
    Minetto, M. A.
    Farina, D.
    JOURNAL OF NEURAL ENGINEERING, 2014, 11 (01)
  • [7] High-density magnetomyography is superior to high-density surface electromyography for motor unit decomposition: a simulation study
    Klotz, Thomas
    Lehmann, Lena
    Negro, Francesco
    Roehrle, Oliver
    JOURNAL OF NEURAL ENGINEERING, 2023, 20 (04)
  • [8] Impact of Motor Unit Action Potential Components on the Motor Unit Identification from Dynamic High-Density Surface Electromyograms
    Glaser, V.
    Holobar, A.
    2017 8TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2017, : 90 - 93
  • [9] Real-Time Motor Unit Identification From High-Density Surface EMG
    Glaser, Vojko
    Holobar, Ales
    Zazula, Damjan
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2013, 21 (06) : 949 - 958
  • [10] Motor unit number estimation using high-density surface electromyography
    van Dijk, Johannes P.
    Blok, Joleen H.
    Lapatki, Bernd G.
    van Schaik, Ivo N.
    Zwarts, Machiel J.
    Stegeman, Dick F.
    CLINICAL NEUROPHYSIOLOGY, 2008, 119 (01) : 33 - 42