High-density magnetomyography is superior to high-density surface electromyography for motor unit decomposition: a simulation study

被引:2
|
作者
Klotz, Thomas [1 ]
Lehmann, Lena [1 ,2 ]
Negro, Francesco [3 ]
Roehrle, Oliver [1 ,2 ]
机构
[1] Univ Stuttgart, Inst Modelling & Simulat Biomech Syst, Pfaffenwaldring 5a, D-70569 Stuttgart, Germany
[2] Stuttgart Ctr Simulat Sci SC SimTech, Pfaffenwaldring 5a, D-70569 Stuttgart, Germany
[3] Univ Brescia, Dept Clin & Expt Sci, Viale Europa 11, I-25123 Brescia, Italy
基金
欧洲研究理事会;
关键词
EMG; MMG; non-invasive; skeletal muscle; motor neuron; blind source separation; ACTION-POTENTIALS; EMG; SYSTEM; SIZE;
D O I
10.1088/1741-2552/ace7f7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Studying motor units is essential for understanding motor control, the detection of neuromuscular disorders and the control of human-machine interfaces. Individual motor unit firings are currently identified in vivo by decomposing electromyographic (EMG) signals. Due to our body's properties and anatomy, individual motor units can only be separated to a limited extent with surface EMG. Unlike electrical signals, magnetic fields do not interact with human tissues. This physical property and the emerging technology of quantum sensors make magnetomyography (MMG) a highly promising methodology. However, the full potential of MMG to study neuromuscular physiology has not yet been explored. Approach. In this work, we perform in silico trials that combine a biophysical model of EMG and MMG with state-of-the-art algorithms for the decomposition of motor units. This allows the prediction of an upper-bound for the motor unit decomposition accuracy. Main results. It is shown that non-invasive high-density MMG data is superior over comparable high-density surface EMG data for the robust identification of the discharge patterns of individual motor units. Decomposing MMG instead of EMG increased the number of identifiable motor units by 76%. Notably, MMG exhibits a less pronounced bias to detect superficial motor units. Significance. The presented simulations provide insights into methods to study the neuromuscular system non-invasively and in vivo that would not be easily feasible by other means. Hence, this study provides guidance for the development of novel biomedical technologies.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Motor unit number estimation based on high-density surface electromyography decomposition
    Peng, Yun
    He, Jinbao
    Yao, Bo
    Li, Sheng
    Zhou, Ping
    Zhang, Yingchun
    CLINICAL NEUROPHYSIOLOGY, 2016, 127 (09) : 3059 - 3065
  • [2] Motor unit number estimation using high-density surface electromyography
    van Dijk, Johannes P.
    Blok, Joleen H.
    Lapatki, Bernd G.
    van Schaik, Ivo N.
    Zwarts, Machiel J.
    Stegeman, Dick F.
    CLINICAL NEUROPHYSIOLOGY, 2008, 119 (01) : 33 - 42
  • [3] Analysis of motor units with high-density surface electromyography
    Merletti, Roberto
    Holobar, Ales
    Farina, Dario
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (06) : 879 - 890
  • [4] High-density surface electromyography provides reliable estimates of motor unit behavior
    Martinez-Valdes, E.
    Laine, C. M.
    Falla, D.
    Mayer, F.
    Farina, D.
    CLINICAL NEUROPHYSIOLOGY, 2016, 127 (06) : 2534 - 2541
  • [5] Motor unit tracking with high-density surface EMG
    Maathuis, Ellen M.
    Drenthen, Judith
    van Dijk, Johannes P.
    Visser, Gerhard H.
    Blok, Joleen H.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (06) : 920 - 930
  • [6] Identifying Motor Units in Longitudinal Studies with High-Density Surface Electromyography
    Martinez-Valdes, Eduardo
    Negro, Francesco
    Laine, Christopher M.
    Falla, Deborah L.
    Mayer, Frank
    Farina, Dario
    CONVERGING CLINICAL AND ENGINEERING RESEARCH ON NEUROREHABILITATION II, VOLS 1 AND 2, 2017, 15 : 147 - 151
  • [7] A new method for high-density surface electromyography decomposition in dynamic muscle contraction
    He J.
    Guan B.
    Huang K.
    Luo Z.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2021, 38 (06): : 1081 - 1086
  • [8] A high-density multichannel surface electromyography system for the characterization of single motor units
    Blok, JH
    van Dijk, JP
    Drost, G
    Zwarts, MJ
    Stegeman, DF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (04): : 1887 - 1897
  • [9] Sex differences in the detection of motor unit action potentials identified using high-density surface electromyography
    Taylor, Christopher A.
    Kopicko, Brian H.
    Negro, Francesco
    Thompson, Christopher K.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2022, 65
  • [10] Design of a Flexible High-Density Surface Electromyography Sensor
    Feng, Jirou
    Chang, Handdeut
    Jeong, Hwayeong
    Kim, Jung
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4130 - 4133