Estimating motor unit discharge patterns from high-density surface electromyogram

被引:215
|
作者
Holobar, Ales [1 ,2 ]
Farina, Dario [3 ]
Gazzoni, Marco [1 ]
Merletti, Roberto [1 ]
Zazula, Damjan [2 ]
机构
[1] Politecn Torino, Lab Ingn Sistema Neuromuscolare, Dipartimento Elettron, I-10129 Turin, Italy
[2] Univ Maribor, Fac Elect Engn & Comp Sci, SLO-2000 Maribor, Slovenia
[3] Aalborg Univ, Ctr Sensory Motor Interact SMI, Dept Hlth Sci & Technol, Aalborg, Denmark
关键词
Motor unit; Discharge pattern; High-density EMG; Surface EMG; Decomposition; CONDUCTION-VELOCITY; AMPLITUDE CANCELLATION; ACTION-POTENTIALS; NORMATIVE DATA; EMG; DECOMPOSITION; MUSCLE; RECRUITMENT; SIZE; SEPARATION;
D O I
10.1016/j.clinph.2008.10.160
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: We systematically tested the capability of the Convolution Kernel Compensation (CKC) method to identify motor unit (MU) discharge patterns from the simulated and experimental surface electromyogram (sEMG) during low-force contractions. Methods- sEMG was detected with a grid of 13 x 5 electrodes. In simulated signals with 20 dB signal-to-noise ratio, 11 +/- 3 out of 63 concurrently active MUs were identified with sensitivity >95% in the estimation of their discharge times. In experimental signals recorded at 0-10% of the maximal force, the discharge partterns of(range) 11-19 MUs (abductor pollicis; n = 8 subjects), 9-17 MUs (biceps brachii; n = 2), 7-11 MUs (upper trapezius: n = 2), and 6-10 MUs(vastus lateralis: n = 2) were identified. In the abductor digiti minimi muscle of one subject, the decomposition results from concurrently recorded sEMG and intramuscular EMG (iEMG) were compared; the two approaches agreed on 98 +/- 1% of-MU discharges. Conclusion: It is possible to identify the discharge patterns of several MUs during low-force contractions From high-density sEMG. Significance: sEMG call be used for the analysis of individual MUs when the application of needles is not desirable or in combination with iEMG to increase the number or sampled MUs. (C) 2009 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:551 / 562
页数:12
相关论文
共 50 条
  • [21] Inter-operator agreement in decomposition of motor unit firings from high-density surface EMG
    Kleine, Bert U.
    van Dijk, Johannes P.
    Zwarts, Machiel J.
    Stegeman, Dick F.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (04) : 652 - 661
  • [22] High-density surface EMG decomposition allows for recording of motor unit discharge from proximal and distal flexion synergy muscles simultaneously in individuals with stroke
    Miller, Laura C.
    Thompson, Christopher K.
    Negro, Francesco
    Heckman, C. J.
    Farina, Dario
    Dewald, Julius P. A.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 5340 - 5344
  • [23] Novel Method for Accuracy Assessment of Individual Motor Unit Firing Identification from High-Density Surface Electromyograms
    Urh, Filip
    Holobar, Ales
    2018 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2018, : 108 - 111
  • [24] Inferring position of motor units from high-density surface EMG
    Lundsberg, Jonathan
    Bjorkman, Anders
    Malesevic, Nebojsa
    Antfolk, Christian
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [25] Inferring position of motor units from high-density surface EMG
    Jonathan Lundsberg
    Anders Björkman
    Nebojsa Malesevic
    Christian Antfolk
    Scientific Reports, 14
  • [26] Cross-Examination of Motor Unit Pulses Improves the Accuracy of Motor Unit Identification from High-Density EMG
    Urh, F.
    Holobar, A.
    CONVERGING CLINICAL AND ENGINEERING RESEARCH ON NEUROREHABILITATION III, 2019, 21 : 1136 - 1140
  • [27] Detecting motor unit abnormalities in amyotrophic lateral sclerosis using high-density surface EMG
    Nishikawa, Yuichi
    Holobar, Ales
    Watanabe, Kohei
    Takahashi, Tetsuya
    Ueno, Hiroki
    Maeda, Noriaki
    Maruyama, Hirofumi
    Tanaka, Shinobu
    Hyngstrom, Allison S.
    CLINICAL NEUROPHYSIOLOGY, 2022, 142 : 262 - 272
  • [28] Analysis of motor units with high-density surface electromyography
    Merletti, Roberto
    Holobar, Ales
    Farina, Dario
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (06) : 879 - 890
  • [29] Analysis of motor unit spike trains estimated from high-density surface electromyography is highly reliable across operators
    Hug, Francois
    Avrillon, Simon
    Del Vecchio, Alessandro
    Casolo, Andrea
    Ibanez, Jaime
    Nuccio, Stefano
    Rossato, Julien
    Holobar, Ales
    Farina, Dario
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2021, 58
  • [30] Robust Identification of Motor Unit Discharges From High-Density Surface EMG in Dynamic Muscle Contractions of the Tibialis Anterior
    Yokoyama, Hikaru
    Sasaki, Atsushi
    Kaneko, Naotsugu
    Saito, Akira
    Nakazawa, Kimitaka
    IEEE ACCESS, 2021, 9 : 123901 - 123911