Comparison of primary standards of length:: He-Ne lasers at λ=633 nm frequency-stabilized to the hyperfine structure of I2

被引:4
|
作者
Balling, P
Smíd, M
Sebek, P
Matus, M
Tomanyiczka, K
Bánréti, E
机构
[1] Czech Metrol Inst, Prague 15072 5, Czech Republic
[2] Bundesamt Eich & Vermessungswesen, A-1160 Vienna, Austria
[3] Orszagos Meresugyi Hivatal, H-1124 Budapest, Hungary
关键词
D O I
10.1088/0026-1394/36/5/5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An international comparison of He-Ne/I-2 lasers at lambda = 633 nm between the CMI (Czech Republic), the OMH (Hungary) and the BEV (Austria) was performed at the CMI-LPM, Prague, in July 1997 as DUNAMET project D3. The frequencies of three national standards of length (lasers) were found to be in the range +/-7 kHz (1.5 parts in 10(11)) and reproducibility of frequency differences between individual lasers during one week was better than +/-5 kHz (1 part in 10(11)). The relative frequency stability, expressed as an Allan standard deviation, reached a minimum of 3 parts in 10(13) for an integration time of 10000 s.
引用
收藏
页码:433 / 437
页数:5
相关论文
共 50 条
  • [1] I2 stabilized 633 nm He-Ne lasers:: 25 years of international comparisons
    Chartier, JM
    Chartier, A
    LASER FREQUENCY STABILIZATION, STANDARDS, MEASUREMENT AND APPLICATIONS, 2001, 4269 : 123 - 133
  • [2] Comparison between the 127I2 stabilized He-Ne lasers wavelength standards at 633 nm
    Qian, Jin
    Liu, Xiu-Ying
    Huang, Xiao-Rong
    Zhang, Zhi-Quan
    Shi, Chun-Ying
    Tan, Hui-Ping
    Xin, Ming
    Wang, Han-Ping
    Cai, Shan
    Liu, Zhong-You
    Zhang, Xiao-Ping
    Jiliang Xuebao/Acta Metrologica Sinica, 2008, 29 (SUPPL.): : 127 - 130
  • [3] International comparisons of He-Ne lasers stabilized with 127I2 at λ ≈ 633 nm -: Part VII:: Comparison of NORAMET 127I2-stabilized He-Ne lasers at λ ≈ 633 nm
    Viliesid, M
    Gutierrez-Munguia, M
    Galvan, CA
    Castillo, HA
    Madej, A
    Hall, JL
    Stone, J
    Chartier, A
    Chartier, JM
    METROLOGIA, 2000, 37 (04) : 317 - 322
  • [4] A new frequency-stabilized design for 633nm He-Ne laser
    Wang Liqiang
    Zuo Aibin
    Peng Yuexiang
    ADVANCED LASER TECHNOLOGIES 2005, PTS 1 AND 2, 2006, 6344
  • [5] Comparison of 127I2-stabilized He-Ne lasers at 633 nm between the MIKES and the BIPM
    Hu, J
    Riski, K
    Chartier, A
    Picard, S
    METROLOGIA, 1997, 34 (05) : 417 - 419
  • [6] COMPARISON BETWEEN THE I-127(2) STABILIZED HE-NE LASERS AT 633 NM AND 612 NM OF THE BIPM AND THE IMGC
    BERTINETTO, F
    CORDIALE, P
    PICOTTO, GB
    CHARTIER, JM
    FELDER, R
    GLASER, MG
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1983, 32 (01) : 72 - 76
  • [7] COMPARISON OF HE-NE LASERS FROM THE LMM AND THE IMGC STABILIZED ON 127I2 AT 633-NM
    DEVICENTE, J
    SANCHEZPEREZ, AM
    BERTINETTO, F
    METROLOGIA, 1994, 30 (05) : 503 - 506
  • [8] I2 CONTROLLED HE-NE LASER AT 633 NM . PRELIMINARY WAVELENGTH
    HANES, GR
    BAIRD, KM
    METROLOGIA, 1969, 5 (01) : 32 - &
  • [9] INTERCOMPARISON OF NORTHERN EUROPEAN I-127(2)-STABILIZED HE-NE LASERS AT LAMBDA = 633 NM
    CHARTIER, JM
    DARNEDDE, H
    FRENNBERG, M
    HENNINGSEN, J
    KARN, U
    PENDRILL, L
    HU, JP
    PETERSEN, JC
    POULSEN, O
    RAMANUJAM, PS
    RIEHLE, F
    ROBERTSSON, L
    STAHLBERG, B
    WAHLGREN, H
    METROLOGIA, 1992, 29 (05) : 331 - 339
  • [10] Frequency comparison of iodine-stabilized he-ne lasers at 633 nm from the IMGC and the IFA-IFTAR
    Bertinetto, F
    Cordiale, P
    Popescu, G
    METROLOGIA, 1996, 33 (06) : 565 - 567