Comparison of primary standards of length:: He-Ne lasers at λ=633 nm frequency-stabilized to the hyperfine structure of I2

被引:4
|
作者
Balling, P
Smíd, M
Sebek, P
Matus, M
Tomanyiczka, K
Bánréti, E
机构
[1] Czech Metrol Inst, Prague 15072 5, Czech Republic
[2] Bundesamt Eich & Vermessungswesen, A-1160 Vienna, Austria
[3] Orszagos Meresugyi Hivatal, H-1124 Budapest, Hungary
关键词
D O I
10.1088/0026-1394/36/5/5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An international comparison of He-Ne/I-2 lasers at lambda = 633 nm between the CMI (Czech Republic), the OMH (Hungary) and the BEV (Austria) was performed at the CMI-LPM, Prague, in July 1997 as DUNAMET project D3. The frequencies of three national standards of length (lasers) were found to be in the range +/-7 kHz (1.5 parts in 10(11)) and reproducibility of frequency differences between individual lasers during one week was better than +/-5 kHz (1 part in 10(11)). The relative frequency stability, expressed as an Allan standard deviation, reached a minimum of 3 parts in 10(13) for an integration time of 10000 s.
引用
收藏
页码:433 / 437
页数:5
相关论文
共 50 条
  • [21] EXPERIMENTAL COMPARISON OF PAIRS OF FREQUENCY STABILIZED HE-NE LASERS
    LATOURRE.JT
    RABINOWI.P
    JACOBS, S
    GOULD, G
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1966, QE 2 (04) : R38 - +
  • [22] Absolute frequency measurement of the iodine-stabilized He-Ne laser at 633 nm
    Yoon, TH
    Ye, J
    Hall, JL
    Chartier, JM
    APPLIED PHYSICS B-LASERS AND OPTICS, 2001, 72 (02): : 221 - 226
  • [23] Absolute frequency measurement of the iodine-stabilized He-Ne laser at 633 nm
    T.H. Yoon
    J. Ye
    J.L. Hall
    J.-M. Chartier
    Applied Physics B, 2001, 72 : 221 - 226
  • [24] Absolute measurement of the hyperfine splittings of six molecular 127I2 lines around the He-Ne/I2 wavelength at λ ≈ 633 nm
    Simonsen, HR
    Rose, F
    METROLOGIA, 2000, 37 (06) : 651 - 658
  • [25] Experimental investigation of the power shift of iodine-stabilized He-Ne lasers at 633 nm
    Hu, J
    Ikonen, E
    Riski, K
    METROLOGIA, 1996, 33 (05) : 467 - 473
  • [26] Influence of Ne isotopes on the single mode operation of He-Ne and He-Ne/I2 lasers
    Cartaleva, Stefka S.
    Dancheva, Yordanka V.
    Gerginov, Vladislav P.
    1997, IEEE, Piscataway, NJ, United States (46)
  • [27] Investigation of two-mode He-Ne laser tubes for frequency-stabilized lasers
    Shurulinkov, S
    Radulov, I
    NINTH INTERNATIONAL SCHOOL ON QUANTUM ELECTRONICS: LASERS-PHYSICS AND APPLICATIONS, 1996, 3052 : 151 - 155
  • [28] Report on RMO supplementary comparison COOMET.L-S9. COOMET 440/RU/08 International comparison of stabilized He-Ne/I2 lasers at wavelength 633 nm
    Chekirda, Konstantin
    Dauletbaev, Aydar
    Kupko, Vladimir
    Makarevich, Vladimir
    METROLOGIA, 2015, 52
  • [29] International comparison of He-Ne lasers stabilized with 127I2 at λ ≈ 633 nm -: Comparison of the fifth- and third-harmonic locking techniques
    Lassila, A
    Riski, K
    Hu, J
    Ahola, T
    Naicheng, S
    Chengyang, L
    Balling, P
    Blabla, J
    Abramova, L
    Zakharenko, YG
    Fedorin, VL
    Chartier, A
    Chartier, JM
    METROLOGIA, 2000, 37 (06) : 701 - 707
  • [30] OVERLAPPING I2 VIBRATIONAL-ROTATIONAL LINES AT 633 NM AS STUDIED WITH A HE-NE LASER
    KNOX, JD
    PAO, YH
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1969, 59 (11) : 1515 - &