Rapid detection and quantification of Enterovirus 71 by a portable surface plasmon resonance biosensor

被引:45
|
作者
Prabowo, Briliant Adhi [1 ,6 ]
Wang, Robert Y. L. [2 ,4 ]
Secario, Muhammad Khari [1 ]
Ou, Po-Ting [2 ]
Alom, Azharul [1 ]
Liu, Jia-Jung [1 ]
Liu, Kou-Chen [1 ,3 ,4 ,5 ]
机构
[1] Chang Gung Univ, Dept Elect Engn, 259 Wenhua 1st Rd, Taoyuan 33002, Taiwan
[2] Chang Gung Univ, Coll Med, Dept Biomed Sci, Taoyuan 33302, Taiwan
[3] Chang Gung Univ, Ctr Biomed Engn, Taoyuan 33302, Taiwan
[4] Chang Gung Mem Hosp, Dept Pediat, Div Pediat Infect Dis, Linkou 33305, Taiwan
[5] Ming Chi Univ Technol, Dept Mat Engn, New Taipei 24301, Taiwan
[6] Indonesian Inst Sci, Res Ctr Informat, Bandung 40135, Indonesia
来源
关键词
EV71; SPR; Sensor; VP1; Virus; Quantification method; SERS-ACTIVE SUBSTRATE; DROPLET DIGITAL PCR; VIRUS-LIKE PARTICLE; QUANTITATIVE DETECTION; JAPANESE ENCEPHALITIS; COXSACKIEVIRUS A16; CRYSTAL-STRUCTURE; EXPRESSION; AMPLIFICATION; ANTIGEN;
D O I
10.1016/j.bios.2017.01.043
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study presents the first report on a label-free detection and rapid quantification method for human enterovirus 71 (EV71) using a portable surface plasmon resonance (SPR) system. The SPR sensor instrument was configured to run on low power in a miniaturized platform to improve the device portability for a wider application both in laboratories and in the field. A color tunable organic light emitting diode in red spectrum was attached on a trapezoidal prism for the disposable light source module. The SPR signal processing using integration area under the reflectivity curve is applied for optimum signal to noise ratio (SNR) enhancement. The major capsid protein VP1 of EV71 was selected as the biomarker target in the detection study. The experimental time required for the EV71 quantification was reduced from 6 days using the conventional viral plaque assay to several minutes using the proposed method. The study results establish a detection limit of approximately 67 virus particles per milliliter (vp/ml) of EV71 in a Dulbecco's modified Eagle's medium. The VP1 detection in the portable SPR biosensor had a detection limit of approximately 4.8 pg/ml in the PBS buffer. Therefore, the proposed direct EV71 viral particle quantification method can be rapidly performed in real time, with high sensitivity and less labor and without assays or fluorescence.
引用
收藏
页码:186 / 191
页数:6
相关论文
共 50 条
  • [41] Localized Surface Plasmon Resonance (LSPR) Biosensor for the Protein Detection
    Maximilien Cottat
    Néné Thioune
    Ana-Maria Gabudean
    Nathalie Lidgi-Guigui
    Monica Focsan
    Simion Astilean
    Marc Lamy de la Chapelle
    Plasmonics, 2013, 8 : 699 - 704
  • [42] Detection of carcinoembryonic antigens using a surface plasmon resonance biosensor
    Su, Fengyu
    Xu, Chunye
    Taya, Minoru
    Murayama, Kimie
    Shinohara, Yasuro
    Nishimura, Shin-Ichiro
    SENSORS, 2008, 8 (07): : 4282 - 4295
  • [43] Surface plasmon resonance biosensor for genetically modified organisms detection
    Mariotti, E
    Minunni, M
    Mascini, M
    ANALYTICA CHIMICA ACTA, 2002, 453 (02) : 165 - 172
  • [44] Advances in Phase Detection Technique of Surface Plasmon Resonance Biosensor
    Yu Xinglong Wei Xing Deng Yan Liu Fangfang Deptof Precision InstrumentsTsinghua UniversityBeijing China
    稀有金属材料与工程, 2006, (S3) : 299 - 304
  • [45] Application of surface plasmon resonance biosensor for the detection of Candida albicans
    Yodmongkol, Sirasa
    Thaweboon, Sroisiri
    Thaweboon, Boonyanit
    Puttharugsa, Chokchai
    Sutapun, Boonsong
    Amarit, Ratthasart
    Somboonkaew, Armote
    Srikhirin, Toemsak
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2016, 55 (02)
  • [46] Detection of bisphenol A using a novel surface plasmon resonance biosensor
    K. Hegnerová
    M. Piliarik
    M. Šteinbachová
    Z. Flegelová
    H. Černohorská
    J. Homola
    Analytical and Bioanalytical Chemistry, 2010, 398 : 1963 - 1966
  • [47] Surface plasmon resonance biosensor for the detection of phenylethanolamine A in swine urine
    Fan, Sufang
    Li, Chunsheng
    Ma, Junmei
    Meng, Zhijuan
    Zhao, Limin
    Zhang, Yan
    ANALYTICAL METHODS, 2021, 13 (10) : 1278 - 1285
  • [48] A surface plasmon resonance biosensor for direct detection of the rabies virus
    Xu, Jing
    Wan, Jia-yu
    Yang, Song-tao
    Zhang, Shou-feng
    Xu, Na
    Li, Nan
    Li, Ji-ping
    Wang, Hai-ying
    Bai, Xue
    Liu, Wen-sen
    ACTA VETERINARIA BRNO, 2012, 81 (02) : 107 - 111
  • [49] Localized Surface Plasmon Resonance (LSPR) Biosensor for the Protein Detection
    Cottat, Maximilien
    Thioune, Nene
    Gabudean, Ana-Maria
    Lidgi-Guigui, Nathalie
    Focsan, Monica
    Astilean, Simion
    de la Chapelle, Marc Lamy
    PLASMONICS, 2013, 8 (02) : 699 - 704
  • [50] Biosensor platform for parallel surface plasmon-enhanced epifluorescence and surface plasmon resonance detection
    Reiner, Agnes T.
    Fossati, Stefan
    Dostalek, Jakub
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 257 : 594 - 601