Rapid detection and quantification of Enterovirus 71 by a portable surface plasmon resonance biosensor

被引:45
|
作者
Prabowo, Briliant Adhi [1 ,6 ]
Wang, Robert Y. L. [2 ,4 ]
Secario, Muhammad Khari [1 ]
Ou, Po-Ting [2 ]
Alom, Azharul [1 ]
Liu, Jia-Jung [1 ]
Liu, Kou-Chen [1 ,3 ,4 ,5 ]
机构
[1] Chang Gung Univ, Dept Elect Engn, 259 Wenhua 1st Rd, Taoyuan 33002, Taiwan
[2] Chang Gung Univ, Coll Med, Dept Biomed Sci, Taoyuan 33302, Taiwan
[3] Chang Gung Univ, Ctr Biomed Engn, Taoyuan 33302, Taiwan
[4] Chang Gung Mem Hosp, Dept Pediat, Div Pediat Infect Dis, Linkou 33305, Taiwan
[5] Ming Chi Univ Technol, Dept Mat Engn, New Taipei 24301, Taiwan
[6] Indonesian Inst Sci, Res Ctr Informat, Bandung 40135, Indonesia
来源
关键词
EV71; SPR; Sensor; VP1; Virus; Quantification method; SERS-ACTIVE SUBSTRATE; DROPLET DIGITAL PCR; VIRUS-LIKE PARTICLE; QUANTITATIVE DETECTION; JAPANESE ENCEPHALITIS; COXSACKIEVIRUS A16; CRYSTAL-STRUCTURE; EXPRESSION; AMPLIFICATION; ANTIGEN;
D O I
10.1016/j.bios.2017.01.043
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study presents the first report on a label-free detection and rapid quantification method for human enterovirus 71 (EV71) using a portable surface plasmon resonance (SPR) system. The SPR sensor instrument was configured to run on low power in a miniaturized platform to improve the device portability for a wider application both in laboratories and in the field. A color tunable organic light emitting diode in red spectrum was attached on a trapezoidal prism for the disposable light source module. The SPR signal processing using integration area under the reflectivity curve is applied for optimum signal to noise ratio (SNR) enhancement. The major capsid protein VP1 of EV71 was selected as the biomarker target in the detection study. The experimental time required for the EV71 quantification was reduced from 6 days using the conventional viral plaque assay to several minutes using the proposed method. The study results establish a detection limit of approximately 67 virus particles per milliliter (vp/ml) of EV71 in a Dulbecco's modified Eagle's medium. The VP1 detection in the portable SPR biosensor had a detection limit of approximately 4.8 pg/ml in the PBS buffer. Therefore, the proposed direct EV71 viral particle quantification method can be rapidly performed in real time, with high sensitivity and less labor and without assays or fluorescence.
引用
收藏
页码:186 / 191
页数:6
相关论文
共 50 条
  • [31] A portable optical-fibre-based surface plasmon resonance biosensor for the detection of therapeutic antibodies in human serum
    Luigi Zeni
    Chiara Perri
    Nunzio Cennamo
    Francesco Arcadio
    Girolamo D’Agostino
    Mario Salmona
    Marten Beeg
    Marco Gobbi
    Scientific Reports, 10
  • [32] Surface Plasmon Resonance (SPR) biosensor for detection of mycotoxins: A review
    Wei, Xiuxia
    Yin, Ming
    Zhang, Li
    Lin, Huaqing
    Wang, Jiale
    Xie, Wenyan
    Xu, Dongpo
    JOURNAL OF IMMUNOLOGICAL METHODS, 2022, 510
  • [33] Detection of TP53 mutation using a portable surface plasmon resonance DNA-based biosensor
    Jiang, TS
    Minunni, M
    Wilson, P
    Zhang, J
    Turner, APF
    Mascini, M
    BIOSENSORS & BIOELECTRONICS, 2005, 20 (10): : 1939 - 1945
  • [34] Simulation of surface plasmon resonance biosensor based on phase detection
    Yu, Xinglong
    Yan, Zibo
    Wang, Dingxin
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2003, 43 (02): : 160 - 163
  • [35] Continuous Detection Method for Ractopamine with Surface Plasmon Resonance Biosensor
    Li Hui
    Cai Hao-Yuan
    Chen Xing
    Sun Jian-Hai
    Zhang Lu-Lu
    Cui Da-Fu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (03) : 381 - 384
  • [36] Scanning surface plasmon resonance biosensor for array sample detection
    Qi, Pan
    Li, Ying
    Feng, Ming-Chuang
    Zhong, Jin-Gang
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2012, 20 (11): : 2365 - 2372
  • [37] Detection of bisphenol A using a novel surface plasmon resonance biosensor
    Hegnerova, K.
    Piliarik, M.
    Steinbachova, M.
    Flegelova, Z.
    Cernohorska, H.
    Homola, J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (05) : 1963 - 1966
  • [38] Advances in phase detection technique of surface plasmon resonance biosensor
    Yu Xinglong
    Wei Xing
    Deng Yan
    Liu Fangfang
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 299 - 304
  • [39] Surface plasmon resonance biosensor for the detection of ochratoxin A in cereals and beverages
    Yuan, Jing
    Deng, Dawei
    Lauren, Denis R.
    Aguilar, Marie-Isabel
    Wu, Yinqiu
    ANALYTICA CHIMICA ACTA, 2009, 656 (1-2) : 63 - 71
  • [40] Surface plasmon resonance biosensor for enzymatic detection of small analytes
    Miyazaki, Celina Massumi
    Shimizu, Flavio Makoto
    Mejia-Salazar, J. R.
    Oliveira, Osvaldo N., Jr.
    Ferreira, Marystela
    NANOTECHNOLOGY, 2017, 28 (14)