Simulation and experimental characterization of a 2-D capacitive micromachined ultrasonic transducer array element

被引:45
|
作者
Oralkan, Ö [1 ]
Jin, XC [1 ]
Degertekin, FL [1 ]
Khuri-Yakub, BT [1 ]
机构
[1] Stanford Univ, Edward L Ginzton Lab, Stanford, CA 94305 USA
关键词
D O I
10.1109/58.808855
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this letter, a 400-mu m x 400-mu m 2-D capacitive micromachined ultrasonic transducer (cMUT) array element is experimentally characterized, and the results are found to be in good agreement with theoretical predictions. As a receiver, the transducer has a 1.8 X 10(-7) nm/root Hz displacement sensitivity, and, as a transmitter, it produces 16.4 kPa/V of output pressure at the transducer surface at 3 MHz. The transducer also has more than 100% fractional bandwidth around 3 MHz, which makes it suitable for ultrasound imaging.
引用
收藏
页码:1337 / 1340
页数:4
相关论文
共 50 条
  • [41] Capacitive micromachined ultrasonic transducer (cMUT) array for the frequency range below 500 kHz
    Buhrdorf, A
    Tebje, L
    Ahrens, O
    Glitza, O
    Binder, J
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 915 - 918
  • [42] Capacitive micromachined ultrasonic transducer (CMUT) array with single-layer graphene membrane
    Chong, Po-Fat
    Shi, Xiaomei
    Cheng, Ching-Hsiang
    MICRO & NANO LETTERS, 2014, 9 (12): : 884 - 886
  • [43] A 32 x 32 Capacitive Micromachined Ultrasonic Transducer Array Manufactured in Standard CMOS
    Lemmerhirt, David F.
    Cheng, Xiaoyang
    White, Robert D.
    Rich, Collin A.
    Zhang, Man
    Fowlkes, J. Brian
    Kripfgans, Oliver D.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (07) : 1521 - 1536
  • [44] Design and performance analysis of capacitive micromachined ultrasonic transducer (CMUT) array for underwater imaging
    Rui Zhang
    Chenyang Xue
    Changde He
    Yongmei Zhang
    Jinlong Song
    Wendong Zhang
    Microsystem Technologies, 2016, 22 : 2939 - 2947
  • [45] Fabrication of a Curved Row-Column Addressed Capacitive Micromachined Ultrasonic Transducer Array
    Chen, Albert I-Hsiang
    Wong, Lawrence L. P.
    Na, Shuai
    Li, Zhenhao
    Macecek, Mirek
    Yeow, John T. W.
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2016, 25 (04) : 675 - 682
  • [46] Curvilinear Capacitive Micromachined Ultrasonic Transducer (CMUT) Array Fabricated Using a Reverse Process
    Caronti, Alessandro
    Coppa, Andrea
    Savoia, Alessandro
    Longo, Cristina
    Gatta, Philipp
    Mauti, Barbara
    Corbo, Antonio
    Calabrese, Beatrice
    Bollino, Giulio
    Paz, Alejandro
    Caliano, Giosue
    Pappalardo, Massimo
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 2092 - 2095
  • [47] Research on optimization sparse method for capacitive micromachined ultrasonic transducer array: heuristic algorithm
    Zhang, Tian
    Zhang, Wendong
    Shao, XingLing
    Wu, Yang
    SENSOR REVIEW, 2021, 41 (03) : 260 - 270
  • [48] Breast Acoustic Parameter Reconstruction Method Based on Capacitive Micromachined Ultrasonic Transducer Array
    Pei, Yu
    Zhang, Guojun
    Zhang, Yu
    Zhang, Wendong
    MICROMACHINES, 2021, 12 (08)
  • [49] Design and performance analysis of capacitive micromachined ultrasonic transducer (CMUT) array for underwater imaging
    Zhang, Rui
    Xue, Chenyang
    He, Changde
    Zhang, Yongmei
    Song, Jinlong
    Zhang, Wendong
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2016, 22 (12): : 2939 - 2947
  • [50] Design of a Wearable 2-D Ultrasonic Transducer Array for Bladder Measurement
    Joung, Do Yeong
    Jo, Hyeong Geun
    Pyun, Joo Young
    Park, Bum Hun
    Park, Kwan Kyu
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2021, 41 (01) : 39 - 49