Coronary CT Angiography: Variability of CT Scanners and Readers in Measurement of Plaque Volume

被引:55
|
作者
Symons, Rolf [1 ]
Morris, Justin Z. [1 ]
Wu, Colin O. [2 ]
Pourmorteza, Amir [1 ]
Ahlman, Mark A. [1 ]
Lima, Joao A. C. [4 ]
Chen, Marcus Y. [3 ]
Mallek, Marissa [1 ]
Sandfort, Veit [1 ]
Bluemke, David A. [1 ]
机构
[1] NIH, Dept Radiol & Imaging Sci, Ctr Clin, 10 Ctr Dr,Bldg 10,Room 1C355, Bethesda, MD 20892 USA
[2] NHLBI, Off Biostat Res, NIH, Bldg 10, Bethesda, MD 20892 USA
[3] NHLBI, Cardiovasc & Pulm Branch, NIH, Bldg 10, Bethesda, MD 20892 USA
[4] Johns Hopkins Univ, Sch Med, Dept Med, Div Cardiol, Baltimore, MD 21205 USA
基金
美国国家卫生研究院;
关键词
COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ATHEROSCLEROTIC PLAQUE; INTRAVASCULAR ULTRASOUND; ARTERY CALCIFICATION; STATIN THERAPY; DUAL-SOURCE; QUANTIFICATION; BURDEN; REPRODUCIBILITY; ACCURACY;
D O I
10.1148/radiol.2016161670
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine reader and computed tomography (CT) scan variability for measurement of coronary plaque volume. Materials and Methods: This HIPAA-compliant study followed Standards for Reporting of Diagnostic Accuracy guidelines. Baseline coronary CT angiography was performed in 40 prospectively enrolled subjects (mean age, 67 years +/- 6 [standard deviation]) with asymptomatic hyperlipidemia by using a 320-detector row scanner (Aquilion One Vision; Toshiba, Otawara, Japan). Twenty of these subjects underwent coronary CT angiography repeated on a separate day with the same CT scanner (Toshiba, group 1); 20 subjects underwent repeat CT performed with a different CT scanner (Somatom Force; Siemens, Forchheim, Germany [group 2]). Intraclass correlation coefficients (ICCs) and BlandAltman analysis were used to assess interreader, intrareader, and interstudy reproducibility. Results: Baseline and repeat coronary CT angiography scans were acquired within 19 days +/- 6. Interreader and intrareader agreement rates were high for total, calcified, and noncalcified plaques for both CT scanners (all ICCs >= 0.96) without bias. Scanner variability was 618.4% (coefficient of variation) with same-vendor follow-up. However, scanner variability increased to 629.9% with different-vendor follow-up. The sample size to detect a 5% change in noncalcified plaque volume with 90% power and an a error of.05 was 286 subjects for same-CT scanner follow-up and 753 subjects with different-vendor follow-up. Conclusion: State-of-the-art coronary CT angiography with same-vendor follow-up has good scan-rescan reproducibility, suggesting a role of coronary CT angiography in monitoring coronary artery plaque response to therapy. Differences between coronary CT angiography vendors resulted in lower scanre-scan reproducibility. (C) RSNA, 2016
引用
收藏
页码:737 / 748
页数:12
相关论文
共 50 条
  • [21] Interscan reproducibility of quantitative coronary plaque volume and composition from CT coronary angiography using an automated method
    Schuhbaeck, Annika
    Dey, Damini
    Otaki, Yuka
    Slomka, Piotr
    Kral, Brian G.
    Achenbach, Stephan
    Berman, Daniel S.
    Fishman, Elliott K.
    Lai, Shenghan
    Lai, Hong
    EUROPEAN RADIOLOGY, 2014, 24 (09) : 2300 - 2308
  • [22] Relationship of epicardial fat volume to coronary plaque, severe coronary stenosis, and high-risk coronary plaque features assessed by coronary CT angiography
    Rajani, Ronak
    Shmilovich, Haim
    Nakazato, Ryo
    Nakanishi, Rine
    Otaki, Yuka
    Cheng, Victor Y.
    Hayes, Sean W.
    Thomson, Louise E. J.
    Friedman, John D.
    Slomka, Piotr J.
    Min, James K.
    Berman, Daniel S.
    Dey, Damini
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (02) : 125 - 132
  • [23] CT coronary angiography: Plaque characterization, prognosis, and clinical applications
    Goldstein, James A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (07) : 1125 - 1126
  • [24] Impact of luminal density on plaque classification by CT coronary angiography
    Maiken Glud Dalager
    Morten Bøttcher
    Gratien Andersen
    Jesper Thygesen
    Erik Morre Pedersen
    Lone Dejbjerg
    Ole Gøtzsche
    Hans Erik Bøtker
    The International Journal of Cardiovascular Imaging, 2011, 27 : 593 - 600
  • [25] Coronary CT angiography and high-risk plaque morphology
    Motoyama S.
    Sarai M.
    Narula J.
    Ozaki Y.
    Cardiovascular Intervention and Therapeutics, 2013, 28 (1) : 1 - 8
  • [26] High-Risk Plaque Features on Coronary CT Angiography
    Hecht, Harvey S.
    Achenbach, Stephan
    Kondo, Takeshi
    Narula, Jagat
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (11) : 1336 - 1339
  • [27] CT Coronary Angiography: Technical Approach and Atherosclerotic Plaque Characterization
    Dell'Aversana, Serena
    Ascione, Raffaele
    Vitale, Raffaella Antonia
    Cavaliere, Fabrizia
    Porcaro, Piercarmine
    Basile, Luigi
    Napolitano, Giovanni
    Boccalatte, Marco
    Sibilio, Gerolamo
    Esposito, Giovanni
    Franzone, Anna
    Di Costanzo, Giuseppe
    Muscogiuri, Giuseppe
    Sironi, Sandro
    Cuocolo, Renato
    Cavaglia, Enrico
    Ponsiglione, Andrea
    Imbriaco, Massimo
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (24)
  • [28] Progression of noncalcified and calcified coronary plaque by CT angiography in SLE
    Khan, Aisha
    Arbab-Zadeh, Armin
    Kiani, Adnan N.
    Magder, Laurence S.
    Petri, Michelle
    RHEUMATOLOGY INTERNATIONAL, 2017, 37 (01) : 59 - 65
  • [29] Automated Coronary CT Angiography Plaque-Lumen Segmentaton
    Cline, Harvey E.
    Krishnan, Karthik
    Napel, Sandy
    Rubin, Geoffrey D.
    Turner, Wesley D.
    Avila, Ricardo S.
    MEDICAL IMAGING 2009: COMPUTER-AIDED DIAGNOSIS, 2009, 7260
  • [30] Progression of Noncalcified and Calcified Coronary Plaque (by CT Angiography) in SLE
    Petri, Michelle
    Zadeh, Armin
    Kiani, Adnan
    Magder, Laurence S.
    ARTHRITIS & RHEUMATOLOGY, 2015, 67