Coronary CT Angiography: Variability of CT Scanners and Readers in Measurement of Plaque Volume

被引:55
|
作者
Symons, Rolf [1 ]
Morris, Justin Z. [1 ]
Wu, Colin O. [2 ]
Pourmorteza, Amir [1 ]
Ahlman, Mark A. [1 ]
Lima, Joao A. C. [4 ]
Chen, Marcus Y. [3 ]
Mallek, Marissa [1 ]
Sandfort, Veit [1 ]
Bluemke, David A. [1 ]
机构
[1] NIH, Dept Radiol & Imaging Sci, Ctr Clin, 10 Ctr Dr,Bldg 10,Room 1C355, Bethesda, MD 20892 USA
[2] NHLBI, Off Biostat Res, NIH, Bldg 10, Bethesda, MD 20892 USA
[3] NHLBI, Cardiovasc & Pulm Branch, NIH, Bldg 10, Bethesda, MD 20892 USA
[4] Johns Hopkins Univ, Sch Med, Dept Med, Div Cardiol, Baltimore, MD 21205 USA
基金
美国国家卫生研究院;
关键词
COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ATHEROSCLEROTIC PLAQUE; INTRAVASCULAR ULTRASOUND; ARTERY CALCIFICATION; STATIN THERAPY; DUAL-SOURCE; QUANTIFICATION; BURDEN; REPRODUCIBILITY; ACCURACY;
D O I
10.1148/radiol.2016161670
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine reader and computed tomography (CT) scan variability for measurement of coronary plaque volume. Materials and Methods: This HIPAA-compliant study followed Standards for Reporting of Diagnostic Accuracy guidelines. Baseline coronary CT angiography was performed in 40 prospectively enrolled subjects (mean age, 67 years +/- 6 [standard deviation]) with asymptomatic hyperlipidemia by using a 320-detector row scanner (Aquilion One Vision; Toshiba, Otawara, Japan). Twenty of these subjects underwent coronary CT angiography repeated on a separate day with the same CT scanner (Toshiba, group 1); 20 subjects underwent repeat CT performed with a different CT scanner (Somatom Force; Siemens, Forchheim, Germany [group 2]). Intraclass correlation coefficients (ICCs) and BlandAltman analysis were used to assess interreader, intrareader, and interstudy reproducibility. Results: Baseline and repeat coronary CT angiography scans were acquired within 19 days +/- 6. Interreader and intrareader agreement rates were high for total, calcified, and noncalcified plaques for both CT scanners (all ICCs >= 0.96) without bias. Scanner variability was 618.4% (coefficient of variation) with same-vendor follow-up. However, scanner variability increased to 629.9% with different-vendor follow-up. The sample size to detect a 5% change in noncalcified plaque volume with 90% power and an a error of.05 was 286 subjects for same-CT scanner follow-up and 753 subjects with different-vendor follow-up. Conclusion: State-of-the-art coronary CT angiography with same-vendor follow-up has good scan-rescan reproducibility, suggesting a role of coronary CT angiography in monitoring coronary artery plaque response to therapy. Differences between coronary CT angiography vendors resulted in lower scanre-scan reproducibility. (C) RSNA, 2016
引用
收藏
页码:737 / 748
页数:12
相关论文
共 50 条
  • [11] CORONARY PLAQUE BURDEN BY QUANTITATIVE CORONARY ANGIOGRAPHY CORRELATES WITH PLAQUE BURDEN BY CT CORONARY ANGIOGRAPHY AND INTRAVASCULAR ULTRASOUND
    Kalynych, Anna M.
    Vazquez, Gustavo
    Karmpaliotis, Dimitri
    Qian, Zhen
    Krivitsky, Eric
    Marvasty, Idean B.
    Rinehart, Sarah
    Voros, Szilard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [12] Quantitative plaque characterization with coronary CT angiography (CTA)
    Schoenhagen, Paul
    Barreto, Mitya
    Halliburton, Sandra S.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (03): : 313 - 316
  • [13] High Risk Plaque Features on Coronary CT Angiography
    Bartykowszki A.
    Celeng C.
    Károlyi M.
    Maurovich-Horvat P.
    Current Cardiovascular Imaging Reports, 2014, 7 (8) : 1 - 12
  • [14] Validation of Quantitative Coronary Plaque Analysis at CT Angiography
    Williams, Michelle C.
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2025, 7 (01):
  • [15] Impact of diabetes on coronary artery plaque volume by coronary CT angiography and subsequent adverse cardiac events
    Deseive, Simon
    Straub, Ramona
    Kupke, Maximilian
    Broersen, Alexander
    Kitslaar, Pieter H.
    Stocker, Thomas J.
    Massberg, Steffen
    Hadamitzky, Martin
    Hausleiter, Joerg
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (01) : 31 - 37
  • [16] Non-invasive measurement of coronary plaque from coronary CT angiography and its clinical implications
    Dey, Damini
    Schuhbaeck, Annika
    Min, James K.
    Berman, Daniel S.
    Achenbach, Stephan
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2013, 11 (08) : 1067 - 1076
  • [17] Coronary Plaque Burden at Coronary CT Angiography in Asymptomatic Men and Women
    Rodriguez, Karen
    Kwan, Alan C.
    Lai, Shenghan
    Lima, Joao A. C.
    Vigneault, Davis
    Sandfort, Veit
    Pattanayak, Puskar
    Ahlman, Mark A.
    Mallek, Marissa
    Sibley, Christopher T.
    Bluemke, David A.
    RADIOLOGY, 2015, 277 (01) : 73 - 80
  • [18] Interscan reproducibility of quantitative coronary plaque volume and composition from CT coronary angiography using an automated method
    Annika Schuhbaeck
    Damini Dey
    Yuka Otaki
    Piotr Slomka
    Brian G. Kral
    Stephan Achenbach
    Daniel S. Berman
    Elliott K. Fishman
    Shenghan Lai
    Hong Lai
    European Radiology, 2014, 24 : 2300 - 2308
  • [19] INTERSCAN REPRODUCIBILITY OF QUANTITATIVE CORONARY PLAQUE VOLUME AND COMPOSITION FROM CT CORONARY ANGIOGRAPHY USING AN AUTOMATED METHOD
    Schuhbaeck, Annika
    Dey, Damini
    Otaki, Yuka
    Kral, Brian
    Slomka, Piotr
    Nakazato, Ryo
    Achenbach, Stephan
    Berman, Daniel
    Fishman, Eliott
    Lai, Shenghan
    Lai, Hong
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1040 - E1040
  • [20] Reply: Impact of diabetes on coronary artery plaque volume by coronary CT angiography and subsequent adverse cardiac events
    Deseive, Simon
    Hausleiter, Joerg
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (02) : E2 - E2