Coronary CT Angiography: Variability of CT Scanners and Readers in Measurement of Plaque Volume

被引:55
|
作者
Symons, Rolf [1 ]
Morris, Justin Z. [1 ]
Wu, Colin O. [2 ]
Pourmorteza, Amir [1 ]
Ahlman, Mark A. [1 ]
Lima, Joao A. C. [4 ]
Chen, Marcus Y. [3 ]
Mallek, Marissa [1 ]
Sandfort, Veit [1 ]
Bluemke, David A. [1 ]
机构
[1] NIH, Dept Radiol & Imaging Sci, Ctr Clin, 10 Ctr Dr,Bldg 10,Room 1C355, Bethesda, MD 20892 USA
[2] NHLBI, Off Biostat Res, NIH, Bldg 10, Bethesda, MD 20892 USA
[3] NHLBI, Cardiovasc & Pulm Branch, NIH, Bldg 10, Bethesda, MD 20892 USA
[4] Johns Hopkins Univ, Sch Med, Dept Med, Div Cardiol, Baltimore, MD 21205 USA
基金
美国国家卫生研究院;
关键词
COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ATHEROSCLEROTIC PLAQUE; INTRAVASCULAR ULTRASOUND; ARTERY CALCIFICATION; STATIN THERAPY; DUAL-SOURCE; QUANTIFICATION; BURDEN; REPRODUCIBILITY; ACCURACY;
D O I
10.1148/radiol.2016161670
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine reader and computed tomography (CT) scan variability for measurement of coronary plaque volume. Materials and Methods: This HIPAA-compliant study followed Standards for Reporting of Diagnostic Accuracy guidelines. Baseline coronary CT angiography was performed in 40 prospectively enrolled subjects (mean age, 67 years +/- 6 [standard deviation]) with asymptomatic hyperlipidemia by using a 320-detector row scanner (Aquilion One Vision; Toshiba, Otawara, Japan). Twenty of these subjects underwent coronary CT angiography repeated on a separate day with the same CT scanner (Toshiba, group 1); 20 subjects underwent repeat CT performed with a different CT scanner (Somatom Force; Siemens, Forchheim, Germany [group 2]). Intraclass correlation coefficients (ICCs) and BlandAltman analysis were used to assess interreader, intrareader, and interstudy reproducibility. Results: Baseline and repeat coronary CT angiography scans were acquired within 19 days +/- 6. Interreader and intrareader agreement rates were high for total, calcified, and noncalcified plaques for both CT scanners (all ICCs >= 0.96) without bias. Scanner variability was 618.4% (coefficient of variation) with same-vendor follow-up. However, scanner variability increased to 629.9% with different-vendor follow-up. The sample size to detect a 5% change in noncalcified plaque volume with 90% power and an a error of.05 was 286 subjects for same-CT scanner follow-up and 753 subjects with different-vendor follow-up. Conclusion: State-of-the-art coronary CT angiography with same-vendor follow-up has good scan-rescan reproducibility, suggesting a role of coronary CT angiography in monitoring coronary artery plaque response to therapy. Differences between coronary CT angiography vendors resulted in lower scanre-scan reproducibility. (C) RSNA, 2016
引用
收藏
页码:737 / 748
页数:12
相关论文
共 50 条
  • [1] Interobserver variability among expert readers quantifying plaque volume and plaque characteristics on coronary CT angiography: a CLARIFY trial sub-study
    Jonas, Rebecca A.
    Weerakoon, Shaneke
    Fisher, Rebecca
    Griffin, William F.
    Kumar, Vishak
    Rahban, Habib
    Marques, Hugo
    Karlsberg, Ronald P.
    Jennings, Robert S.
    Crabtree, Tami R.
    Choi, Andrew D.
    Earls, James P.
    CLINICAL IMAGING, 2022, 91 : 19 - 25
  • [2] Coronary CT angiography (CCTA) and advances in CT plaque imaging
    Tillmann Cyrus
    Robert J. Gropler
    Pamela K. Woodard
    Journal of Nuclear Cardiology, 2009, 16 : 466 - 473
  • [3] Coronary CT angiography (CCTA) and advances in CT plaque imaging
    Cyrus, Tillmann
    Gropler, Robert J.
    Woodard, Pamela K.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (03) : 466 - 473
  • [4] Iterative model reconstruction reduces calcified plaque volume in coronary CT angiography
    Karolyi, Mihaly
    Szilveszter, Balint
    Kolossvary, Marton
    Takx, Richard A. P.
    Celeng, Csilla
    Bartykowszki, Andrea
    Jermendy, Adam L.
    Panajotu, Alexisz
    Karady, Jlia
    Raaijmakers, Rolf
    Giepmans, Walter
    Merkely, Bela
    Maurovich-Horvat, Pal
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 87 : 83 - 89
  • [5] Comprehensive plaque assessment by coronary CT angiography
    Pál Maurovich-Horvat
    Maros Ferencik
    Szilard Voros
    Béla Merkely
    Udo Hoffmann
    Nature Reviews Cardiology, 2014, 11 : 390 - 402
  • [6] Comprehensive plaque assessment by coronary CT angiography
    Maurovich-Horvat, Pal
    Ferencik, Maros
    Voros, Szilard
    Merkely, Bela
    Hoffmann, Udo
    NATURE REVIEWS CARDIOLOGY, 2014, 11 (07) : 390 - 402
  • [7] Evaluation of Plaque Morphology by Coronary CT Angiography
    Fujimoto, Shinichiro
    Kondo, Takeshi
    Narula, Jagat
    CARDIOLOGY CLINICS, 2012, 30 (01) : 69 - +
  • [8] Hepatosteatosis and Atherosclerotic Plaque at Coronary CT Angiography
    Carter, Jessica
    Heseltine, Thomas D.
    Meah, Mohammed N.
    Tzolos, Evangelos
    Kwiecinski, Jacek
    Doris, Mhairi
    McElhinney, Priscilla
    Moss, Alastair J.
    Adamson, Philip D.
    Hunter, Amanda
    Alam, Shirjel
    Shah, Anoop S., V
    Pawade, Tania
    Wang, Chengjia
    Weir-McCall, Jonathan R.
    Roditi, Giles
    van Beek, Edwin J. R.
    Nicol, Edward D.
    Shaw, Leslee J.
    Berman, Daniel S.
    Slomka, Piotr J.
    Mills, Nicholas L.
    Dweck, Marc R.
    Newby, David E.
    Murray, Scott W.
    Dey, Damini
    Williams, Michelle C.
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2022, 4 (02):
  • [9] Plaque rupture after coronary CT angiography
    Hojo, Kana
    Otsuka, Kenichiro
    Kasayuki, Noriaki
    EUROPEAN HEART JOURNAL, 2023, 44 (09) : 782 - 782
  • [10] Coronary Artery CT Angiography for Plaque Imaging
    Chrysant G.S.
    Current Cardiovascular Imaging Reports, 2010, 3 (6) : 366 - 371