Automatic Segmentation of Corneal Microlayers on Optical Coherence Tomography Images

被引:14
|
作者
Elsawy, Amr [1 ,2 ]
Abdel-Mottaleb, Mohamed [2 ]
Sayed, Ibrahim-Osama [1 ]
Wen, Dan [1 ]
Roongpoovapatr, Vatookarn [1 ]
Eleiwa, Taher [1 ,3 ]
Sayed, Ahmed M. [1 ,4 ]
Raheem, Mariam [1 ]
Gameiro, Gustavo [1 ]
Abou Shousha, Mohamed [1 ,2 ,5 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, 900 Northwest 17th St, Miami, FL 33136 USA
[2] Univ Miami, Elect & Comp Engn, Coral Gables, FL 33136 USA
[3] Benha Fac Med, Ophthalmol Dept, Banha, Egypt
[4] Helwan Univ, Fac Engn, Biomed Engn Dept, Helwan, Egypt
[5] Univ Miami, Biomed Engn, Coral Gables, FL 33136 USA
来源
关键词
OCT imaging; segmentation; corneal microlayers; IN-VIVO CHARACTERISTICS; TOPOGRAPHIC THICKNESS; DIAGNOSIS; MEMBRANE; LAYER; OCT;
D O I
10.1167/tvst.8.3.39
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To propose automatic segmentation algorithm (AUS) for corneal microlayers on optical coherence tomography (OCT) images. Methods: Eighty-two corneal OCT scans were obtained from 45 patients with normal and abnormal corneas. Three testing data sets totaling 75 OCT images were randomly selected. Initially, corneal epithelium and endothelium microlayers are estimated using a corneal mask and locally refined to obtain final segmentation. Flat-epithelium and flat-endothelium images are obtained and vertically projected to locate inner corneal microlayers. Inner microlayers are estimated by translating epithelium and endothelium microlayers to detected locations then refined to obtain final segmentation. Images were segmented by trained manual operators (TMOs) and by the algorithm to assess repeatability (i.e., intraoperator error), reproducibility (i.e., interoperator and segmentation errors), and running time. A random masked subjective test was conducted by corneal specialists to subjectively grade the segmentation algorithm. Results: Compared with the TMOs, the AUS had significantly less mean intraoperator error (0.53 +/- 1.80 vs. 2.32 +/- 2.39 pixels; P < 0.0001), it had significantly different mean segmentation error (3.44 +/- 3.46 vs. 2.93 +/- 3.02 pixels; P < 0.0001), and it had significantly less running time per image (0.19 +/- 0.07 vs. 193.95 +/- 194.53 seconds; P < 0.0001). The AUS had insignificant subjective grading for microlayer-segmentation grading (4.94 +/- 032 vs. 4.96 +/- 0.24; P = 0.5081), but it had significant subjective grading for regional-segmentation grading (4.96 +/- 0.26 vs. 4.79 +/- 0.60; P = 0.025). Conclusions: The AUS can reproduce the manual segmentation of corneal microlayers with comparable accuracy in almost real-time and with significantly better repeatability. Translational Relevance: The AUS can be useful in clinical settings and can aid the diagnosis of corneal diseases by measuring thickness of segmented corneal microlayers.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Automatic segmentation of accumulated fluid inside the retinal layers from optical coherence tomography images
    Sahoo, M.
    Pal, S.
    Mitra, M.
    MEASUREMENT, 2017, 101 : 138 - 144
  • [32] High-speed automatic segmentation of intravascular stent struts in optical coherence tomography images
    Han, M.
    Kim, D.
    Oh, W. Y.
    Ryu, S.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS IX, 2013, 8565
  • [33] Automatic Choroid Layer Segmentation from Optical Coherence Tomography Images Using Deep Learning
    Saleha Masood
    Ruogu Fang
    Ping Li
    Huating Li
    Bin Sheng
    Akash Mathavan
    Xiangning Wang
    Po Yang
    Qiang Wu
    Jing Qin
    Weiping Jia
    Scientific Reports, 9
  • [34] A Complete Review of Automatic Detection, Segmentation, and Quantification of Neovascularization in Optical Coherence Tomography Angiography Images
    Tun, Yar Zar
    Aimmanee, Pakinee
    DIAGNOSTICS, 2023, 13 (22)
  • [35] Automatic choroidal segmentation in optical coherence tomography images based on curvelet transform and graph theory
    Eghtedar, Reza Alizadeh
    Esmaeili, Mahdad
    Peyman, Alireza
    Akhlaghi, Mohammadreza
    Rasta, Seyed Hossein
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2023, 13 (02): : 92 - 100
  • [36] Segmentation of 830nm and 1310nm LASIK corneal optical coherence tomography images
    Li, Y
    Shekhar, R
    Huang, D
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 167 - 178
  • [37] Automated Segmentation of the Choroid in Retinal Optical Coherence Tomography Images
    Lu, Huiqi
    Boonarpha, Nattapon
    Kwong, Man Ting
    Zheng, Yalin
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 5869 - 5872
  • [38] Automated Segmentation of Dental Calculus in Optical Coherence Tomography Images
    Lee, Chia-Yen
    Chuang, Ching-Cheng
    Chen, Guan-Jie
    Huang, Chih-Chia
    Lee, Shyh-Yuan
    Lin, Yu-Hsien
    SENSORS AND MATERIALS, 2018, 30 (11) : 2517 - 2529
  • [39] Segmentation Based Sparse Reconstruction of Optical Coherence Tomography Images
    Fang, Leyuan
    Li, Shutao
    Cunefare, David
    Farsiu, Sina
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (02) : 407 - 421
  • [40] Segmentation of the urothelium in optical coherence tomography images with dynamic contrast
    Xu, Zhuo
    Zhu, Hui
    Wang, Hui
    JOURNAL OF BIOMEDICAL OPTICS, 2021, 26 (08)