Automatic Segmentation of Corneal Microlayers on Optical Coherence Tomography Images

被引:14
|
作者
Elsawy, Amr [1 ,2 ]
Abdel-Mottaleb, Mohamed [2 ]
Sayed, Ibrahim-Osama [1 ]
Wen, Dan [1 ]
Roongpoovapatr, Vatookarn [1 ]
Eleiwa, Taher [1 ,3 ]
Sayed, Ahmed M. [1 ,4 ]
Raheem, Mariam [1 ]
Gameiro, Gustavo [1 ]
Abou Shousha, Mohamed [1 ,2 ,5 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, 900 Northwest 17th St, Miami, FL 33136 USA
[2] Univ Miami, Elect & Comp Engn, Coral Gables, FL 33136 USA
[3] Benha Fac Med, Ophthalmol Dept, Banha, Egypt
[4] Helwan Univ, Fac Engn, Biomed Engn Dept, Helwan, Egypt
[5] Univ Miami, Biomed Engn, Coral Gables, FL 33136 USA
来源
关键词
OCT imaging; segmentation; corneal microlayers; IN-VIVO CHARACTERISTICS; TOPOGRAPHIC THICKNESS; DIAGNOSIS; MEMBRANE; LAYER; OCT;
D O I
10.1167/tvst.8.3.39
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To propose automatic segmentation algorithm (AUS) for corneal microlayers on optical coherence tomography (OCT) images. Methods: Eighty-two corneal OCT scans were obtained from 45 patients with normal and abnormal corneas. Three testing data sets totaling 75 OCT images were randomly selected. Initially, corneal epithelium and endothelium microlayers are estimated using a corneal mask and locally refined to obtain final segmentation. Flat-epithelium and flat-endothelium images are obtained and vertically projected to locate inner corneal microlayers. Inner microlayers are estimated by translating epithelium and endothelium microlayers to detected locations then refined to obtain final segmentation. Images were segmented by trained manual operators (TMOs) and by the algorithm to assess repeatability (i.e., intraoperator error), reproducibility (i.e., interoperator and segmentation errors), and running time. A random masked subjective test was conducted by corneal specialists to subjectively grade the segmentation algorithm. Results: Compared with the TMOs, the AUS had significantly less mean intraoperator error (0.53 +/- 1.80 vs. 2.32 +/- 2.39 pixels; P < 0.0001), it had significantly different mean segmentation error (3.44 +/- 3.46 vs. 2.93 +/- 3.02 pixels; P < 0.0001), and it had significantly less running time per image (0.19 +/- 0.07 vs. 193.95 +/- 194.53 seconds; P < 0.0001). The AUS had insignificant subjective grading for microlayer-segmentation grading (4.94 +/- 032 vs. 4.96 +/- 0.24; P = 0.5081), but it had significant subjective grading for regional-segmentation grading (4.96 +/- 0.26 vs. 4.79 +/- 0.60; P = 0.025). Conclusions: The AUS can reproduce the manual segmentation of corneal microlayers with comparable accuracy in almost real-time and with significantly better repeatability. Translational Relevance: The AUS can be useful in clinical settings and can aid the diagnosis of corneal diseases by measuring thickness of segmented corneal microlayers.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Segmentation of inner microlayers of abnormal cornea in Optical Coherence Tomography images using graph segmentation
    Elsawy, Amr
    Eleiwa, Taher Kamel
    Raheem, Mariam
    Gregori, Giovanni
    Abdel-Mottaleb, Mohamed
    Abou Shousha, Mohamed
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (11)
  • [2] Automatic Segmentation of Macular Holes in Optical Coherence Tomography Images
    Mendes, Odilon L. C.
    Lucena, Daniel R.
    Lucena, Abrahao R.
    Cavalcante, Tarique S.
    Albuquerque, Victor Hugo C. De
    Altaf, Meteb
    Hassan, Mohammad Mehedi
    Alexandria, Auzuir R.
    IEEE ACCESS, 2021, 9 (09): : 96487 - 96500
  • [3] Automatic segmentation of anterior segment optical coherence tomography images
    Williams, Dominic
    Zheng, Yalin
    Bao, Fangjun
    Elsheikh, Ahmed
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (05)
  • [4] Automatic Plaque Segmentation in Coronary Optical Coherence Tomography Images
    Zhang, Huaqi
    Wang, Guanglei
    Li, Yan
    Lin, Feng
    Han, Yechen
    Wang, Hongrui
    INTERNATIONAL JOURNAL OF PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE, 2019, 33 (14)
  • [5] Automatic Measurement Method for Corneal Thickness of Optical Coherence Tomography Images
    Gao Yang
    Li Zhongliang
    Zhang Jianhua
    Nan Nan
    Wang Xuan
    Wang Xiangzhao
    ACTA OPTICA SINICA, 2019, 39 (03)
  • [6] Automatic Measurement Method for Corneal Thickness of Optical Coherence Tomography Images
    Gao Y.
    Li Z.
    Zhang J.
    Nan N.
    Wang X.
    Wang X.
    Guangxue Xuebao/Acta Optica Sinica, 2019, 39 (03):
  • [7] Automatic vessel lumen segmentation in optical coherence tomography (OCT) images
    Zhang, Huaizhong
    Essa, Ehab
    Xie, Xianghua
    APPLIED SOFT COMPUTING, 2020, 88
  • [8] Automatic Segmentation of Vessel Lumen in Intravascular Optical Coherence Tomography Images
    Wang, Ancong
    Tang, Xiaoying
    2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 948 - 953
  • [9] Automatic Segmentation of Corneal Lamellar Graft Surfaces from Low-Contrast Optical Coherence Tomography Images
    Arshavsky, Alec
    LaRocca, Francesco
    Izatt, Joseph
    Kuo, Anthony
    Farsiu, Sina
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [10] Segmentation of Corneal Optical Coherence Tomography Images Using Randomized Hough Transform
    Elsawy, Amr
    Abdel-Mottaleb, Mohamed
    Abou Shousha, Mohamed
    MEDICAL IMAGING 2019: IMAGE PROCESSING, 2019, 10949