Poly(phenylenesulfide)-based coatings for carbon steel heat exchanger tubes in geothermal environments

被引:22
|
作者
Sugama, T [1 ]
Elling, D
Gawlik, K
机构
[1] Brookhaven Natl Lab, Energy Resources Div, Energy Sci & Technol Dept, Upton, NY 11973 USA
[2] Natl Renewable Energy Lab, Golden, CO 80401 USA
关键词
D O I
10.1023/A:1020806012202
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To inhibit corrosion and fouling by calcium silicate and silica scales of the carbon steel heat exchanger tubes in geothermal power plants operating at brine temperature of 160degreesC, their internal surfaces were lined with high-temperature performance poly( phenylenesulfide) (PPS)-based coating systems. The systems included the PPS containing polytetrafluoroethylene (PTFE) as an anti-oxidant additive, silicon carbide (SiC) as a thermally conductive filler, and aluminum oxide-rich calcium aluminate (ACA) as an abrasive wear resistant filler. Then, the lined tubes underwent an eleven-month-long field exposure at the site of power plant. The results from the post-test analyses of the exposed liners revealed that these PPS coating systems had an excellent thermal stability, and satisfyingly withstood this brine temperature, and also greatly resisted the permeation of brine, demonstrating that they adequately protect the tubes against corrosion in a wet, harsh geothermal environment. Furthermore, modifying the surfaces of the PPS top layer with PTFE, retarded the hydrothermal oxidation of the liner, thereby reducing significantly the rate of scale deposition and creating surfaces unsusceptible to reactions with scales. Thus, all the scales deposited on the liner's surfaces were readily scoured off by hydroblasting at a very low pressure. By contrast, although the stainless steel tubes had a great protection against corrosion, the formation of passive oxide layers at their outermost surface sites was detrimental in that they became more susceptible to scale deposition and developed strong adherence to the scales. As a result, the high-pressure hydroblasting was required to remove this scale adhering to the tubes' surfaces. (C) 2002 Kluwer Academic Publishers.
引用
收藏
页码:4871 / 4880
页数:10
相关论文
共 50 条
  • [31] Fouling of carbon steel heat exchanger caused by iron bacteria
    Starosvetsky, J
    Armon, R
    Groysman, A
    Starosvetsky, D
    MATERIALS PERFORMANCE, 1999, 38 (01) : 55 - 61
  • [32] Mill Scale Corrosion and Prevention in Carbon Steel Heat Exchanger
    Sharma, Pankaj
    Roy, Himadri
    HIGH TEMPERATURE MATERIALS AND PROCESSES, 2015, 34 (06) : 571 - 576
  • [33] Protective effect of superhydrophobic coatings on carbon steel in different environments
    Vigdorovich, V. I.
    Tsygankova, L. E.
    Uryadnikova, M. N.
    Emel'yanenko, K. A.
    Chulkova, E. V.
    Uryadnikov, A. A.
    INTERNATIONAL JOURNAL OF CORROSION AND SCALE INHIBITION, 2021, 10 (03): : 1157 - 1167
  • [34] PROPERTIES OF WELDED JOINTS IN GRADE 12KHIMF STEEL HEAT EXCHANGER TUBES
    BAZHENOV, VV
    WELDING PRODUCTION, 1968, 15 (11): : 36 - &
  • [35] Failure Analysis of Duplex Stainless Steel for Heat Exchanger Tubes with Seawater Cooling Medium
    Ardy, Husaini
    Albatros, Thomas
    Sumboja, Afriyanti
    METALS, 2023, 13 (07)
  • [36] Development of a compact laminar flow heat exchanger with stainless steel micro-tubes
    Saji, N
    Nagai, S
    Tsuchiya, K
    Asakura, H
    Obata, M
    PHYSICA C, 2001, 354 (1-4): : 148 - 151
  • [37] EXPERIMENTAL-STUDY ON IMPACT FRETTING IN HEAT-EXCHANGER TUBES WITH BRUSH PLATED COATINGS
    DAI, ZD
    LUBRICATION ENGINEERING, 1994, 50 (11): : 905 - 908
  • [38] Design of Geothermal Buried Tube Heat Exchanger Based on the Double Source Heat Pump Systems
    Wei Riguang
    Wu Xuyang
    Gao Jianqiang
    Ma Minghao
    Liu Zhongliang
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER AND RENEWABLE ENERGY (ICPRE), 2016, : 680 - 683
  • [39] Poly(O-anisidine) coatings on low carbon steel
    Wankhede, MG
    Koinkar, PM
    More, MA
    Patil, PP
    Gangal, SA
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2002, 332 (1-2): : 161 - 166
  • [40] A Fault Detection System for a Geothermal Heat Exchanger Sensor Based on Intelligent Techniques
    Alaiz-Moreton, Hector
    Castejon-Limas, Manuel
    Casteleiro-Roca, Jose-Luis
    Jove, Esteban
    Fernandez Robles, Laura
    Luis Calvo-Rolle, Jose
    SENSORS, 2019, 19 (12)