Theoretical modeling of Positive Displacement Motors performance

被引:10
|
作者
Nguyen, T. C. [1 ]
Al-Safran, E. [2 ,3 ]
Nguyen, V. [4 ,5 ]
机构
[1] New Mexico Inst Min & Technol, Petr Engn, 801 Leroy Pl, Socorro, NM 87801 USA
[2] Kuwait Univ, Petr Engn, Coll Engn & Petr, Safat, Kuwait
[3] Kuwait Univ, Coll Engn & Petr, Res & Acad Affairs, Safat, Kuwait
[4] Ha Noi Univ Min & Geol, Fac Oil & Gas, Hanoi, Vietnam
[5] Ha Noi Univ Min & Geol, Geotech Res Ctr, Hanoi, Vietnam
关键词
Positive displacement motor (PDM); Theoretical modeling; Motor performance; Downhole mud motor; PROGRESSING CAVITY PUMP;
D O I
10.1016/j.petrol.2018.03.049
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Positive Displacement Motor (PDM) has been used extensively in directional and horizontal drilling operations. To the best of our knowledge, there is no reliable analytical model to predict the performance of PDMs. Based on motor geometry; each PDM has its own unique performance that is experimentally obtained by manufacturers using water as a testing fluid. These experiments are not only costly and time-consuming, but also with conditions that do not represent the actual down-hole conditions. The key to improve the prediction of motor performance is to, accurately; determine the flowing cross-sectional area of PDM. This paper uses Nguyen et al. (2014) model for calculating flow area of a multi-lobe progressing cavity pump, in addition to two developed analytical models for predicting the actual performance of a multi-lobe PDM. A sensitivity analysis was performed to optimize motor geometry to maximize motor torque. The developed models were validated using experimental data from a single 1:2-lobe and multi 2:3-lobe PDMs. The results revealed that when the stator lobe number is greater than five, torque is maximized if the dimensionless motor geometry is zero. The flowing cross-sectional area is reduced when the stator lobe number is higher than four lobes. However, the flow rate is always higher when the stator lobe number is increased. The results also showed that it is not recommended designing a PDM which has the stator lobe greater than twelve. Furthermore, model validation showed that the proposed model predicts the actual multi-lobe PDM performance with average percent error of less than 6% when differential pressure across the motor is 300 psi or less. The results of this study are not only important for manufacturers to optimize PDM design, but also for operators to improve the performance and efficiency of PDMs.
引用
收藏
页码:188 / 197
页数:10
相关论文
共 50 条
  • [31] Fixed displacement motors from Linde
    不详
    DIESEL PROGRESS NORTH AMERICAN EDITION, 2000, 66 (03): : 88 - 88
  • [32] Theoretical modeling technology for gyroplane flight performance
    Science and Technology on Rotorcraft Aeromechanics Laboratory, Nanjing University of Aeronautics and Astronautics, Nanjing
    210016, China
    Hangkong Xuebao, 12 (3244-3253):
  • [33] Theoretical background of the operating parameters of the satellite working mechanism of the hydraulic positive displacement machine
    Pawel Sliwinski
    Scientific Reports, 15 (1)
  • [34] Theoretical Modeling and Numerical Study for Thrust-Oscillation Characteristics in Solid Rocket Motors
    Zhang, Qiao
    Wei, Zhi-jun
    Su, Wan-xing
    Li, Jun-wei
    Wang, Ning-fei
    JOURNAL OF PROPULSION AND POWER, 2012, 28 (02) : 312 - 322
  • [35] Theoretical Modeling of Asymmetrically Inclined Fiber Optic Displacement Sensor: A Blended Approach
    Dixit, Pallavi C.
    Patil, Supriya S.
    Kulkarni, Sunil G.
    Shaligram, Arvind D.
    FIBER AND INTEGRATED OPTICS, 2023, 42 (06) : 232 - 244
  • [36] Theoretical modeling, simulation and experimental studies of fiber optic bundle displacement sensor
    Patil, Supriya S.
    Buchade, P. B.
    Shaligram, A. D.
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 201 : 79 - 85
  • [37] Theoretical modeling of attenuated displacement amplification for multistage compliant mechanism and its application
    Ling, Mingxiang
    Cao, Junyi
    Jiang, Zhou
    Lin, Jing
    SENSORS AND ACTUATORS A-PHYSICAL, 2016, 249 : 15 - 22
  • [38] THE DESIGN AND PREDICTED PERFORMANCE OF A REGENERATIVE SYSTEM FOR TESTING POSITIVE DISPLACEMENT PUMPS
    EDGE, KA
    HARRIS, RM
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 1991, 113 (04): : 714 - 720
  • [39] DIMENSIONS AND IDENTIFICATION CODE FOR MOUNTING FLANGES AND SHAFTS FOR POSITIVE DISPLACEMENT HYDRAULIC FLUID POWER PUMPS AND MOTORS.
    Anon
    American National Standards Institute, Standards, 1972,
  • [40] Quantitative and qualitative evaluation of various positive-displacement compressor modeling platforms
    Tanveer, M. Mohsin
    Bradshaw, Craig R.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 119 : 48 - 63