Theoretical modeling of Positive Displacement Motors performance

被引:10
|
作者
Nguyen, T. C. [1 ]
Al-Safran, E. [2 ,3 ]
Nguyen, V. [4 ,5 ]
机构
[1] New Mexico Inst Min & Technol, Petr Engn, 801 Leroy Pl, Socorro, NM 87801 USA
[2] Kuwait Univ, Petr Engn, Coll Engn & Petr, Safat, Kuwait
[3] Kuwait Univ, Coll Engn & Petr, Res & Acad Affairs, Safat, Kuwait
[4] Ha Noi Univ Min & Geol, Fac Oil & Gas, Hanoi, Vietnam
[5] Ha Noi Univ Min & Geol, Geotech Res Ctr, Hanoi, Vietnam
关键词
Positive displacement motor (PDM); Theoretical modeling; Motor performance; Downhole mud motor; PROGRESSING CAVITY PUMP;
D O I
10.1016/j.petrol.2018.03.049
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Positive Displacement Motor (PDM) has been used extensively in directional and horizontal drilling operations. To the best of our knowledge, there is no reliable analytical model to predict the performance of PDMs. Based on motor geometry; each PDM has its own unique performance that is experimentally obtained by manufacturers using water as a testing fluid. These experiments are not only costly and time-consuming, but also with conditions that do not represent the actual down-hole conditions. The key to improve the prediction of motor performance is to, accurately; determine the flowing cross-sectional area of PDM. This paper uses Nguyen et al. (2014) model for calculating flow area of a multi-lobe progressing cavity pump, in addition to two developed analytical models for predicting the actual performance of a multi-lobe PDM. A sensitivity analysis was performed to optimize motor geometry to maximize motor torque. The developed models were validated using experimental data from a single 1:2-lobe and multi 2:3-lobe PDMs. The results revealed that when the stator lobe number is greater than five, torque is maximized if the dimensionless motor geometry is zero. The flowing cross-sectional area is reduced when the stator lobe number is higher than four lobes. However, the flow rate is always higher when the stator lobe number is increased. The results also showed that it is not recommended designing a PDM which has the stator lobe greater than twelve. Furthermore, model validation showed that the proposed model predicts the actual multi-lobe PDM performance with average percent error of less than 6% when differential pressure across the motor is 300 psi or less. The results of this study are not only important for manufacturers to optimize PDM design, but also for operators to improve the performance and efficiency of PDMs.
引用
收藏
页码:188 / 197
页数:10
相关论文
共 50 条
  • [21] Simplified steady-state modeling of positive displacement compressors
    Hjortland, Andrew L.
    Crawford, Roy R.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 159 : 333 - 343
  • [22] Selection of the required number of circulating subs in a special assembly and investigation of their performance during drilling of radial branching channels by sectional positive displacement motors
    Lyagov, Ilya A.
    Lyagov, Aleksandr, V
    Isangulov, Dinislam R.
    Lyagova, Anastasiya A.
    JOURNAL OF MINING INSTITUTE, 2024, 265 : 78 - 86
  • [23] THEORETICAL MODELING OF THE DEVELOPMENT OF THE POSITIVE SPARK IN LONG GAPS
    BONDIOU, A
    GALLIMBERTI, I
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1994, 27 (06) : 1252 - 1266
  • [24] Accurate Modeling and Performance Analysis of IPM-PMASR Motors
    Armando, Eric
    Guglielmi, Paolo
    Pellegrino, Gianmario
    Pastorelli, Michele
    Vagati, Alfredo
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (01) : 123 - 130
  • [25] POSITIVE DISPLACEMENT FLOWMETERS - HIGH-PERFORMANCE WITH A LITTLE CARE
    HENDRIX, AR
    INSTRUMENTATION TECHNOLOGY, 1982, 29 (12): : 47 - 49
  • [26] EFFECT OF STATOR GEOMETRY ON THE PERFORMANCE OF A POSITIVE DISPLACEMENT HYDRAULIC TURBINE
    Sonawat, Arihant
    Kim, Jin-Hyuk
    Kim, Seung-Jun
    Choi, Young-Seok
    Yang, Hyeon-Mo
    Lee, Yong-Kab
    Kim, Kyung-Min
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2019, VOL 3B, 2019,
  • [27] Preliminary design and performance analysis of a positive displacement hydraulic turbine
    Sonawat, Arihant
    Kim, Seung-Jun
    Choi, Young-Seok
    Lee, Kyoung-Yong
    Kim, Kyung Min
    Lee, Yong-Kab
    Kim, Jin-Hyuk
    29TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, 2019, 240
  • [28] POSITIVE DISPLACEMENT FLOWMETERS: HIGH PERFORMANCE - WITH A LITTLE CARE.
    Hendrix, Archie R.
    InTech, 1982, 29 (12) : 47 - 49
  • [29] Sizing and performance features of rotary and reciprocating positive displacement pumps
    Cooper Paul
    Wang Chaowei
    排灌机械工程学报, 2014, 32 (12) : 1013 - 1022
  • [30] Modeling of digital-displacement pump-motors and their application as hydraulic drives for nonuniform loads
    Ehsan, M
    Rampen, WHS
    Salter, SH
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2000, 122 (01): : 210 - 215