Dosimetric analysis of a 900-MHz rat head exposure system

被引:45
|
作者
Leveque, P [1 ]
Dale, C
Veyret, B
Wiart, J
机构
[1] CNRS, UMR 6615, InstRech Commun Opt & Microondes, F-33607 Limoges, France
[2] France Telecom, Ctr Natl Etud Telecommun, F-92794 Issy Les Moulineaux, France
[3] CNRS, UMR 5501, Lab PIOM, F-33607 Bordeaux, France
[4] France Telecom, Res Ctr, F-92794 Issy Les Moulineaux, France
关键词
dosimetry; finite difference time domain (FDTD); loop antenna; mobile phone; RF exposure system; specific absorption rate (SAR);
D O I
10.1109/TMTT.2004.831984
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a dosimetric analysis of a specific exposure system used to locally expose the heads of rats. This system operating at 900 MHz consists of a restrainer and a loop antenna having two metallic lines printed on a dielectric substrate; one of the extremities of the metallic structure forms a loop and is placed close to the head of the animal placed in a cylindrical "rocket-like" restrainer. This local-exposure system was analyzed using the finite-difference time-domain method. Comparisons between measurements and simulations were carried out using a homogeneous rat model. The aim of the study was to compare the exposure of the rat and human head in specific tissues such as the dura matter (DM). Specific absorption rate (SAR) levels were calculated in a heterogeneous rat phantom. With an input power of 1 W, the brain-averaged SAR was equal to 6.8 W/kg. Using a statistical approach, the maximum SAR in specific tissues was extracted. With an input power of 1 W, the maximum SAR inside the skull was estimated at 15.5+/-5 W/kg, while the maximum SAR in the skin was 33+/-5 W/kg. A comparison was made between SAR levels in a human head exposed to a global system for mobile communication handset operating at 900 MHz (250-mW output power) and those obtained in the rat tissues with a 100-mW input power at the connector of the loop. In this case, simulations showed that the ratio of the maximum local SAR in the rat versus human was 1.3+/-0.6 in the brain, 1.0+/-0.5 in the skin, and 1.2+/-0.6 in the DM.
引用
收藏
页码:2076 / 2083
页数:8
相关论文
共 50 条
  • [41] FURTHER CONTROVERSY SHAPING UP OVER 900-MHZ ALLOCATIONS
    不详
    ELECTRONICS, 1973, 46 (10): : 29 - 29
  • [42] A 900-MHz 1-V CMOS frequency synthesizer
    Dehng, GK
    Yang, CY
    Hsu, JM
    Liu, SI
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2000, 35 (08) : 1211 - 1214
  • [43] Effects of 900-MHz Microwave Radiation on -Ray-Induced Damage to Mouse Hematopoietic System
    Cao, Yi
    Xu, Qian
    Jin, Zong-Da
    Zhang, Jun
    Lu, Min-Xia
    Nie, Ji-Hua
    Tong, Jian
    JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2010, 73 (07): : 507 - 513
  • [44] The effect on rat peripheral nerve morphology and function of a 900-MHz electromagnetic field applied in the prenatal period
    Hanci, Hatice
    Yenilmez, Engin
    Demir, Selim
    Yildirim, Mehmet
    Gedikli, Oznur
    Kaya, Haydar
    ELECTROMAGNETIC BIOLOGY AND MEDICINE, 2025,
  • [45] A 900-MHz transceiver chipset for two-way paging applications
    Sanielevici, SA
    Cioffi, KR
    Ahrari, B
    Stephenson, PS
    Skoglund, DL
    Zargari, M
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1998, 33 (12) : 2160 - 2168
  • [46] 900-MHz Nonthermal Atmospheric Pressure Plasma Jet for Biomedical Applications
    Choi, Jun
    Mohamed, Abdel-Aleam H.
    Kang, Sung Kil
    Woo, Kyung Chul
    Kim, Kyong Tai
    Lee, Jae Koo
    PLASMA PROCESSES AND POLYMERS, 2010, 7 (3-4) : 258 - 263
  • [47] The design of a 2-V 900-MHz CMOS bandpass amplifier
    Cheng, Y
    Wu, CY
    Gong, J
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2001, 27 (03) : 197 - 210
  • [48] DC-coupled IF stage design for a 900-MHz ISM receiver
    Harjani, R
    Kim, J
    Harvey, J
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2003, 38 (01) : 126 - 134
  • [49] The effects of prenatal long-duration exposure to 900-MHz electromagnetic field on the 21-day-old newborn male rat liver
    Topal, Zehra
    Hanci, Hatice
    Mercantepe, Tolga
    Erol, Huseyin Serkan
    Keles, Osman Nuri
    Kaya, Haydar
    Mungan, Sevdegul
    Odaci, Ersan
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2015, 45 (02) : 291 - 297
  • [50] SAR CALCULATIONS IN AN ANATOMICALLY REALISTIC MODEL OF THE HEAD FOR MOBILE COMMUNICATION TRANSCEIVERS AT 900-MHZ AND 1.8-GHZ
    DIMBYLOW, PJ
    MANN, SM
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10): : 1537 - 1553