Dosimetric analysis of a 900-MHz rat head exposure system

被引:45
|
作者
Leveque, P [1 ]
Dale, C
Veyret, B
Wiart, J
机构
[1] CNRS, UMR 6615, InstRech Commun Opt & Microondes, F-33607 Limoges, France
[2] France Telecom, Ctr Natl Etud Telecommun, F-92794 Issy Les Moulineaux, France
[3] CNRS, UMR 5501, Lab PIOM, F-33607 Bordeaux, France
[4] France Telecom, Res Ctr, F-92794 Issy Les Moulineaux, France
关键词
dosimetry; finite difference time domain (FDTD); loop antenna; mobile phone; RF exposure system; specific absorption rate (SAR);
D O I
10.1109/TMTT.2004.831984
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a dosimetric analysis of a specific exposure system used to locally expose the heads of rats. This system operating at 900 MHz consists of a restrainer and a loop antenna having two metallic lines printed on a dielectric substrate; one of the extremities of the metallic structure forms a loop and is placed close to the head of the animal placed in a cylindrical "rocket-like" restrainer. This local-exposure system was analyzed using the finite-difference time-domain method. Comparisons between measurements and simulations were carried out using a homogeneous rat model. The aim of the study was to compare the exposure of the rat and human head in specific tissues such as the dura matter (DM). Specific absorption rate (SAR) levels were calculated in a heterogeneous rat phantom. With an input power of 1 W, the brain-averaged SAR was equal to 6.8 W/kg. Using a statistical approach, the maximum SAR in specific tissues was extracted. With an input power of 1 W, the maximum SAR inside the skull was estimated at 15.5+/-5 W/kg, while the maximum SAR in the skin was 33+/-5 W/kg. A comparison was made between SAR levels in a human head exposed to a global system for mobile communication handset operating at 900 MHz (250-mW output power) and those obtained in the rat tissues with a 100-mW input power at the connector of the loop. In this case, simulations showed that the ratio of the maximum local SAR in the rat versus human was 1.3+/-0.6 in the brain, 1.0+/-0.5 in the skin, and 1.2+/-0.6 in the DM.
引用
收藏
页码:2076 / 2083
页数:8
相关论文
共 50 条
  • [31] Effect of head-only sub-chronic and chronic exposure to 900-MHz GSM electromagnetic fields on spatial memory in rats
    Ammari, Mohamed
    Jacquet, Aurelie
    Lecomte, Anthony
    Sakly, Mohsen
    Abdelmelek, Hafedh
    de Seze, Rene
    BRAIN INJURY, 2008, 22 (13-14) : 1021 - 1029
  • [32] High sensitivity 900-MHz ISM band transceiver
    Itoh, N
    Hirashiki, K
    Terada, T
    Kikuta, M
    Ishizuka, S
    Koto, T
    Suzuki, T
    Aoki, H
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2005, E88A (02) : 498 - 506
  • [33] Surface-mount capacitors craft 900-MHz oscillator
    Ingalls, M
    MICROWAVES & RF, 1997, 36 (04) : 102 - &
  • [34] IC AMP MIXER CONVERTS 900-MHZ RF TO 100-MHZ IF
    GOODENOUGH, F
    ELECTRONIC DESIGN, 1993, 41 (26) : 98 - 99
  • [35] A 900-MHz RFID system with TAG-antenna magnetically-coupled to the die
    Finocchiaro, Alessandro
    Ferla, Giuseppe
    Girlando, Giovanni
    Carrara, Francesco
    Palmisano, Giuseppe
    2008 IEEE RADIO FREQUENCY INTEGRATED CIRCUITS SYMPOSIUM, VOLS 1 AND 2, 2008, : 251 - +
  • [36] 900-MHZ DOWN-CONVERTER CONSUMES LITTLE POWER
    MANCINI, R
    MATARAZZO, R
    EDN, 1995, 40 (13) : 60 - 62
  • [37] The neuroprotective effects of baobab and black seed on the rat hippocampus exposed to a 900-MHz electromagnetic field
    Mohamed, Hamza
    Deniz, Omur Gulsum
    Kaplan, Suleyman
    JOURNAL OF CHEMICAL NEUROANATOMY, 2024, 137
  • [38] Design and Evaluation of a Cylindrical Antenna for RFID in the 900-MHz Band
    Uno, Junpei
    Shimasaki, Hitoshi
    2015 IEEE CONFERENCE ON ANTENNA MEASUREMENTS & APPLICATIONS (CAMA), 2015,
  • [39] A 2.7-V 900-MHz CMOS LNA and mixer
    Karanicolas, AN
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1996, 31 (12) : 1939 - 1944
  • [40] Effect of 900-MHz Electromagnetic Field on the Cerebellum: A Histopathological Investigation
    Mercantepe, Tolga
    Tumkaya, Levent
    Gokce, Mehmet Fatih
    Topal, Zehra Suzan
    Esmer, Erva
    MEDICAL BULLETIN OF SISLI ETFAL HOSPITAL, 2018, 52 (02): : 129 - 134