Gamma-Ray Source Positioning Using Array NaI(Tl) Detectors in the Radiation Portal Monitors

被引:1
|
作者
Wang, Qibiao [1 ,2 ]
Deng, Chao [1 ]
Yang, Jianbo [2 ]
Shi, Rui [1 ]
Zhang, Songbai [1 ]
Tuo, Xianguo [1 ,2 ]
机构
[1] Sichuan Univ Sci & Engn, Zigong 643000, Peoples R China
[2] Chengdu Univ Technol, Coll Nucl Technol & Automat Engn, Chengdu 610059, Sichuan, Peoples R China
关键词
RPMs; Source positioning; Monte Carlo; NaI(Tl) detector;
D O I
10.3938/jkps.75.196
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Radiation portal monitors (RPMs) are globally employed in ports to decrease the illicit trafficking of nuclear materials. Most RPMs are generally considered as threshold devices because they utilize large plastic scintillators, which have limited energy resolution and no position sensitivity, to count the gamma-rays and neutrons emitted by nuclear materials. Hence, we designed an RPM detector system with NaI(Tl) detectors inserted into the plastic scintillators to realize gamma-ray source identification and positioning. In this work, a 2D gamma-ray source positioning algorithm based on the attenuation law and solidangle variation was studied with the simulation results, and the variation of the positioning deviations with the real positions was spline interpolated to calibrate the calculated position. The testing experiment showed a small root mean square error (RMSE) for both x (0.86 cm) and y (1.52 cm) after calibration.
引用
收藏
页码:196 / 201
页数:6
相关论文
共 50 条
  • [31] Reset charge sensitive amplifier for NaI(Tl) gamma-ray spectrometer
    Zeng, Guoqiang
    Tan, Chengjun
    Li, Qiang
    Ge, Liangquan
    Liu, Xiyao
    Luo, Qun
    APPLIED RADIATION AND ISOTOPES, 2015, 97 : 63 - 69
  • [32] Autonomous NaI(Tl) gamma-ray spectrometer for in situ underwater measurements
    Naumenko, A.
    Andrukhovich, S.
    Kabanov, V.
    Kabanau, D.
    Kurochkin, Yu.
    Martsynkevich, B.
    Shoukavy, Dz.
    Shpak, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 908 : 97 - 109
  • [33] Point-Source Detection Using Gamma-Ray Spectra in Radiation-portal Monitoring
    Burr, Tom
    Hamada, Michael S.
    Myers, Kary
    Skurikhin, Misha
    JOURNAL OF QUALITY TECHNOLOGY, 2013, 45 (03) : 285 - 296
  • [34] COMPUTER EVALUATION OF NAI(TL) AND GE(LI) GAMMA-RAY SPECTRA
    QUITTNER, P
    WAINERDI, RE
    ATOMIC ENERGY REVIEW, 1970, 8 (02) : 361 - &
  • [35] Measurement of natural radioactivity in marble found in Pakistan using a NaI(Tl) gamma-ray spectrometer
    Iqbal, M
    Tufail, M
    Mirza, SM
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2000, 51 (02) : 255 - 265
  • [36] Prediction of transmitted gamma-ray spectra measured with NaI(Tl) detector using neural network
    Kucuk, N
    Kucuk, I
    ANNALS OF NUCLEAR ENERGY, 2006, 33 (05) : 401 - 404
  • [37] Hybrid analytical method for calibrating a standard NaI(Tl) gamma-ray scintillation detector using a lateral hexagonal radioactive source
    Badawi, Mohamed S.
    Hamzawy, A.
    Thabet, Abouzeid A.
    AIP ADVANCES, 2022, 12 (06)
  • [38] Distribution of natural radioactivity and radiological hazard using a NaI(Tl) gamma-ray spectrometric system
    Abu Shayeb, M.
    Majid, A.
    Zobidi, S.
    JOURNAL OF BUILDING PHYSICS, 2017, 40 (04) : 324 - 333
  • [39] Efficiency measurement of NaI(Tl) detector for a long tube volume source of 6.13MeV gamma-ray
    Shi, ZR
    Xu, K
    Ding, SY
    Wang, SQ
    Guo, ZR
    Zuo, LZ
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (02): : 124 - 129
  • [40] SuN: Summing NaI(Tl) gamma-ray detector for capture reaction measurements
    Simon, A.
    Quinn, S. J.
    Spyrou, A.
    Battaglia, A.
    Beskin, I.
    Best, A.
    Bucher, B.
    Couder, M.
    DeYoung, P. A.
    Fang, X.
    Goerres, J.
    Kontos, A.
    Li, Q.
    Liddick, S. N.
    Long, A.
    Lyons, S.
    Padmanabhan, K.
    Peace, J.
    Roberts, A.
    Robertson, D.
    Smith, K.
    Smith, M. K.
    Stech, E.
    Stefanek, B.
    Tan, W. P.
    Tang, X. D.
    Wiescher, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 703 : 16 - 21