Gamma-Ray Source Positioning Using Array NaI(Tl) Detectors in the Radiation Portal Monitors

被引:1
|
作者
Wang, Qibiao [1 ,2 ]
Deng, Chao [1 ]
Yang, Jianbo [2 ]
Shi, Rui [1 ]
Zhang, Songbai [1 ]
Tuo, Xianguo [1 ,2 ]
机构
[1] Sichuan Univ Sci & Engn, Zigong 643000, Peoples R China
[2] Chengdu Univ Technol, Coll Nucl Technol & Automat Engn, Chengdu 610059, Sichuan, Peoples R China
关键词
RPMs; Source positioning; Monte Carlo; NaI(Tl) detector;
D O I
10.3938/jkps.75.196
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Radiation portal monitors (RPMs) are globally employed in ports to decrease the illicit trafficking of nuclear materials. Most RPMs are generally considered as threshold devices because they utilize large plastic scintillators, which have limited energy resolution and no position sensitivity, to count the gamma-rays and neutrons emitted by nuclear materials. Hence, we designed an RPM detector system with NaI(Tl) detectors inserted into the plastic scintillators to realize gamma-ray source identification and positioning. In this work, a 2D gamma-ray source positioning algorithm based on the attenuation law and solidangle variation was studied with the simulation results, and the variation of the positioning deviations with the real positions was spline interpolated to calibrate the calculated position. The testing experiment showed a small root mean square error (RMSE) for both x (0.86 cm) and y (1.52 cm) after calibration.
引用
收藏
页码:196 / 201
页数:6
相关论文
共 50 条
  • [21] Calibration of cylindrical NaI(Tl) gamma-ray detector intended for truncated conical radioactive source
    Badawi, Mohamed S.
    Thabet, Abouzeid A.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (04) : 1421 - 1430
  • [23] THE OPTIMIZATION OF SMALL CSI(TL) GAMMA-RAY DETECTORS
    BIRD, AJ
    CARTER, T
    DEAN, AJ
    RAMSDEN, D
    SWINYARD, BM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 395 - 399
  • [24] IN-SITU GAMMA-RAY SPECTROMETRY FOR RADIOACTIVITY ANALYSIS OF SOIL USING NaI(Tl) AND LaBr3(Ce) DETECTORS
    Lee, Jun-Ho
    Byun, Jong-In
    RADIATION PROTECTION DOSIMETRY, 2019, 187 (03) : 300 - 309
  • [25] Causes of the diurnal variation observed in gamma-ray spectrum using NaI (Tl) detector
    Datar, Gauri
    Vichare, Geeta
    Selvaraj, C.
    Bhaskar, Ankush
    Raghav, Anil
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2020, 207
  • [26] Quantitative analysis of NaI(Tl) gamma-ray spectrometry using an artificial neural network
    Kim, Jinhwan
    Lim, Kyung Taek
    Kim, Junhyeok
    Kim, Chang-jong
    Jeon, Byoungil
    Park, Kyeongjin
    Kim, Giyoon
    Kim, Hojik
    Cho, Gyuseong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 944
  • [27] INTEGRATED NEUTRON GAMMA-RAY PORTAL MONITORS FOR NUCLEAR SAFEGUARDS
    FEHLAU, PE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 922 - 926
  • [28] Development of gamma-ray emitting test sources for portal monitors
    Pibida, L.
    Unterweger, M.
    Karam, L.
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) : 1271 - 1272
  • [29] A NAI(TL) SCINTILLATION SPECTROMETER STUDY OF PROTON GAMMA-RAY COINCIDENCES
    ALLEN, RC
    MAY, JE
    RALL, W
    PHYSICAL REVIEW, 1951, 84 (06): : 1203 - 1206
  • [30] Pileup Correction Algorithms for Very-High-Count-Rate Gamma-Ray Spectrometry With NaI(Tl) Detectors
    Bolic, Miodrag
    Drndarevic, Vujo
    Gueaieb, Wail
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (01) : 122 - 130