Surface dose measurements with GafChromic EBT film for 6 and 18 MV photon beams

被引:44
|
作者
Bilge, Hatice [1 ]
Cakir, Aydin [1 ]
Okutan, Murat [1 ]
Acar, Hilal [1 ]
机构
[1] Istanbul Univ, Inst Oncol, Dept Med Phys, TR-34390 Istanbul, Turkey
关键词
Surface dose; High energy photons; GafChromic EBT films; PARALLEL IONIZATION CHAMBERS; RADIOCHROMIC FILM; WATER;
D O I
10.1016/j.ejmp.2008.05.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to determine the surface doses using GafChromic EBT films and compare them with plane-parallel. ionization chamber measurements for 6 and 18 MV high energy photon beams. The measurements were made in a water equivalent solid phantom in the build-up region of the 6 and 18 MV photon beams at 100 cm SSD for various field sizes. Markus type plane-parallel ion chamber with fixed-separation between collecting electrodes was used to measure the percent depth doses. GafChromic EBT film measurements were performed both on the phantom surface and maximum dose depth at the same geometry with ion chamber measurements. The surface doses found using GafChromic EBT film were 15%, 20%, 29% and 39% +/- 2% (1SD) for 6 MV photons, 6%, 11%, 23% and 32% +/- 2% (1SD) for 18 MV photons at 5, 10, 20 and 30 cm(2) field sizes, respectively. GafChromic EBT film provides precise measurements for surface dose in the high energy photons. Agreement between film and plane-parallel chamber measurements was found to be within +/- 3% for 18 MV photon beams. There was 5% overestimate on the surface doses when compared with the plane-parallel chamber measurements for all field sizes in the 6 MV photon beams. (C) 2008 Published by Elsevier Ltd on behalf of Associazione Italiana di Fisica Medica.
引用
收藏
页码:101 / 104
页数:4
相关论文
共 50 条
  • [1] Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams
    Ataei, Gholamreza
    Rezaei, Maral
    Gorji, Ebrahimnejad
    Banaei, Amin
    Goushbolagh, Nouraddin Abdi
    Farhood, Bagher
    Bagheri, Mahmoud
    Firouzjah, Razzagh Abedi
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2019, 9 (03): : 204 - 210
  • [2] Systematic Evaluation of Uncertainties Associated with GAFCHROMIC EBT2 Film Dosimetry for 6MV Photon Beams
    Kim, J.
    Kim, S.
    Shaikh, M.
    Li, H.
    Huang, Y.
    Wen, N.
    Glide-Hurst, C.
    Jin, J.
    Nurushev, T.
    Chetty, I. J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Analysis of uncertainties in Gafchromic® EBT film dosimetry of photon beams
    Martisikova, Maria
    Ackermann, Benjamin
    Jaekel, Oliver
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (24): : 7013 - 7027
  • [4] Accurate dosimetry with GafChromic™ EBT film of a 6 MV photon beam in water:: What level is achievable?
    van Batturn, L. J.
    Hoffmans, D.
    Piersma, H.
    Heukelom, S.
    MEDICAL PHYSICS, 2008, 35 (02) : 704 - 716
  • [5] Surface dose and build-up region measurements with wedge filters for 6 and 18 MV photon beams
    Bilge, Hatice
    Ozbek, Nurdan
    Okutan, Murat
    Cakir, Aydin
    Acar, Hilal
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (02): : 110 - 116
  • [6] Surface dose and build-up region measurements with wedge filters for 6 and 18 MV photon beams
    Hatice Bilge
    Nurdan Ozbek
    Murat Okutan
    Aydın Cakir
    Hilal Acar
    Japanese Journal of Radiology, 2010, 28 : 110 - 116
  • [7] The Evaluation of the Gafchromic EBT3 Film in Low Dose 6 MV X-Ray Beams with Different Scanning Modes
    Lee, H.
    Kim, D.
    Chung, W.
    Sung, J.
    Yoon, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 298 - 298
  • [8] Peripheral dose measurements for 6 and 18 MV photon beams on a linear accelerator with multileaf collimator
    Mazonakis, Michalis
    Zacharopoulou, Fotini
    Varveris, Haralambos
    Damilakis, John
    MEDICAL PHYSICS, 2008, 35 (10) : 4396 - 4403
  • [9] Gafchromic EBT film dosimetry in proton beams
    Zhao, Li
    Das, Indra J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (10): : N291 - N301
  • [10] Beam quality and dose rate dependency of Gafchromic EBT3 film irradiated with therapeutic megavolt photon beams
    Sharma, Megha
    Singh, Ranjit
    Robert, N.
    Trivedi, G.
    Tomar, P.
    Oinam, A. S.
    RADIATION MEASUREMENTS, 2021, 146