Cancellation of motion artifact in MRI due to 2D rigid translational motion

被引:5
|
作者
Tang, L
Ohya, M
Sato, Y
Naito, H
Harada, K
Tamura, S
机构
[1] KANSAI ELECT POWER CO INC,CONSTRUCT SECT,HIGASHI SUMIYOSHI BRANCH,OSAKA 546,JAPAN
[2] KAIZUKA MUNICIPAL HOSP,DEPT RADIOL,KAIZUKA,OSAKA 597,JAPAN
关键词
MRI; translational motion; artifact correction;
D O I
10.1016/S0010-4825(96)00035-2
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
A new algorithm for cancelling MRI artifact due to translational motion in the image plane is described. Unlike the conventional iterative phase retrieval algorithm, in which there is no guarantee for the convergence, a direct method for estimating the motion is proposed. In the previous approach, the motions in the readout(x-) direction and the phase encoding(y-) direction are estimated simultaneously. However, the feature of the each x- and y-directional motion is different. Based on the analysis of their features, each x- and y-directional motion is cancelled by different algorithms in two steps. First, we notice that the x-directional motion corresponds to a shift of the x-directional spectrum of the MRI signal, so the x-directional motion can be cancelled by shifting the spectrum in inverse direction. Next, the y-directional motion is cancelled using a new constraint, with which the motion component and the true image component can be separated. The algorithm is shown to be effective by simulations. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:211 / 222
页数:12
相关论文
共 50 条
  • [21] Motion Artifact Cancellation in Wearable Photoplethysmography Using Gyroscope
    Lee, H.
    Chung, H.
    Lee, J.
    IEEE SENSORS JOURNAL, 2019, 19 (03) : 1166 - 1175
  • [22] Head Motion Classification with 2D Motion Estimation
    Baytas, Inci M.
    Gunsel, Bilge
    2014 22ND SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2014, : 325 - 328
  • [23] Towards Eliminating the Displacement Bias Due to Out-Of-Plane Motion in 2D Inverse Problems: A Case of General Rigid-Body Motion
    Siddiqui, M. Z.
    STRAIN, 2015, 51 (01) : 55 - 70
  • [24] 2D motion analysis of long axis cardiac tagged MRI
    Chen, Ting
    Chung, Sohae
    Axel, Leon
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION- MICCAI 2007, PT 2, PROCEEDINGS, 2007, 4792 : 469 - +
  • [25] STABILIZATION OF TRANSLATIONAL MOTION OF A CONTROLLED RIGID BODY
    APYKHTIN, NG
    PIONTKOVSKII, AA
    CHIKHLADZE, TM
    PMM JOURNAL OF APPLIED MATHEMATICS AND MECHANICS, 1977, 41 (03): : 582 - 585
  • [26] Learning non-rigid 3D shape from 2D motion
    Torresani, L
    Hertzmann, A
    Bregler, C
    ADVANCES IN NEURAL INFORMATION PROCESSING SYSTEMS 16, 2004, 16 : 1555 - 1562
  • [27] Motion Artifact Cancellation of Seismocardiographic Recording From Moving Subjects
    Yang, Chenxi
    Tavassolian, Negar
    IEEE SENSORS JOURNAL, 2016, 16 (14) : 5702 - 5708
  • [28] Motion artifact cancellation in NIR spectroscopy using Wiener filtering
    Izzetoglu, M
    Devaraj, A
    Bunce, S
    Onaral, B
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (05) : 934 - 938
  • [29] Dual-electrode motion artifact cancellation for mobile electroencephalography
    Nordin, Andrew D.
    Hairston, W. David
    Ferris, Daniel P.
    JOURNAL OF NEURAL ENGINEERING, 2018, 15 (05)
  • [30] CycleGAN Based Motion Artifact Cancellation for Photoplethysmography Wearable Device
    Nguyen Mai Hoang Long
    Kim, Jong Jin
    Lee, Boon Giin
    Chung, Wan Young
    INTELLIGENT HUMAN COMPUTER INTERACTION, IHCI 2021, 2022, 13184 : 138 - 144