Rehabilitation of reinforced concrete slab-column connections

被引:4
|
作者
El-Salakawy, EF [1 ]
Polak, MA
Soudki, KA
机构
[1] Univ Sherbrooke, Dept Genie Civil, Sherbrooke, PQ J1K 2R1, Canada
[2] Univ Waterloo, Dept Civil Engn, Waterloo, ON N2L 3G1, Canada
关键词
concrete slabs; punching shear; rehabilitation; edge connections; openings; studs; repair;
D O I
10.1139/L02-045
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper presents work on punching shear rehabilitation and strengthening of existing slab-column connections. Four full-scale specimens representing slab-column edge connections were built and tested to failure. Three slabs were then repaired and strengthened and tested again. In the originally tested slabs, which were chosen for repair, one slab had an opening in front of the column and contained shear reinforcement, one slab had an opening and no shear reinforcement, and one had no opening and no reinforcement. The dimensions of the slabs were 1540 x 1020 x 120 mm with square columns (250 x 250 mm). The openings in the specimens were square (150 x 150 mm) with the sides parallel to the sides of the column. The slabs were made using normal weight concrete (28-day average compressive strength of 32 MPa) and reinforced with a reinforcement ratio of 0.75%. The slabs were repaired by replacing old-damaged concrete with new concrete of the same properties. Strengthening was carried out using shear studs for the two slabs, which originally did not have shear reinforcement. The rehabilitation increased the punching shear strength (by 26-41%) and the ductility of the connections. All repaired specimens failed in flexure.
引用
收藏
页码:602 / 611
页数:10
相关论文
共 50 条
  • [41] Effect of high-strength concrete slab on the behavior of slab-column connections
    Marzouk, H
    Emam, M
    Hilal, MS
    ACI STRUCTURAL JOURNAL, 1998, 95 (03) : 227 - 237
  • [42] Experimental and numerical investigation of punching shear capacity of corroded reinforced concrete slab-column connections
    Qian, Kai
    Liu, Jin-Ge
    Yu, Xiao-Hui
    Weng, Yun-Hao
    STRUCTURES, 2022, 43 : 1548 - 1557
  • [43] SHEAR REINFORCEMENT AT SLAB-COLUMN CONNECTIONS IN A REINFORCED-CONCRETE FLAT-PLATE STRUCTURE
    PILLAI, SU
    KIRK, W
    SCAVUZZO, L
    JOURNAL OF THE AMERICAN CONCRETE INSTITUTE, 1982, 79 (01): : 36 - 42
  • [44] Performance of severely damaged reinforced concrete flat slab-column connections strengthened with Carbon Fiber Reinforced Polymer
    Silva, M. A. L.
    Dedigamuwa, K., V
    Gamage, J. C. P. H.
    COMPOSITE STRUCTURES, 2021, 255
  • [45] Effectiveness of Externally Applied CFRP Stirrups for Rehabilitation of Slab-Column Connections
    Erdogan, Hakan
    Zohrevand, Pedram
    Mirmiran, Amir
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2013, 17 (06)
  • [46] Behavior of Monotonically Loaded Slab-Column Connections Reinforced with Shear Studs
    Dam, Thai X.
    Wight, James K.
    Parra-Montesinos, Gustavo
    Gayed, Ramez B.
    ACI STRUCTURAL JOURNAL, 2017, 114 (06) : 1660 - 1662
  • [47] Dynamic model test of a reinforced concrete slab-column system
    PLA University of Science and Technology, Nanjing 210007, China
    不详
    Tumu Gongcheng Xuebao, 2006, 7 (39-42):
  • [48] Development of Headed Bars in Slab-Column Joints of Reinforced Concrete Slab Bridges
    Papadopoulos, Vasileios
    Murcia-Delso, Juan
    Shing, P. Benson
    ACI STRUCTURAL JOURNAL, 2018, 115 (05) : 1393 - 1406
  • [49] Punching Shear Resistance of Interior GFRP Reinforced Slab-Column Connections
    Long Nguyen-Minh
    Rovnak, Marian
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2013, 17 (01) : 2 - 13
  • [50] Fragility Assessment of Slab-Column Connections
    Gogus, Aysegul
    Wallace, John W.