摘要
A novel method is proposed to measure NO in breath. Breath NO is a useful diagnostic measure for asthma patients. Due to the low water solubility of NO, existing wet chemical NO measurements are conducted on NO2 after removal of pre-existing NO2 and conversion of NO to NO2. In contrast, this study utilizes direct measurement of NO by wet chemistry. Gaseous NO was collected into an aqueous phase by a honeycomb-patterned microchannel scrubber and reacted with diaminofluorescein-2 (DAF-2). Fluorescence of the product was measured using a miniature detector, comprising a blue light-emitting diode (LED) and a photodiode. The response intensity was found to dramatically increase following addition of NO2 into the absorbing solution or air sample. By optimizing the conditions, the sensitivity obtained was sufficient to measure parts per billion by volume levels of NO continuously. The system was applied to real analysis of NO in breath, and the effect of coexisting compounds was investigated. The proposed system could successfully measure breath NO.
引用
收藏
页码:7031 / 7037
页数:7
相关论文
共 50 条
  • [41] Fluorescence detection of nitric oxide based on cheletropic spin traps
    Bätz, M
    Korth, HG
    Meineke, P
    Sustmann, R
    NITRIC OXIDE, PT C, 1999, 301 : 532 - 539
  • [42] Photocatalytic oxidation of nitric oxide from simulated flue gas by wet scrubbing using ultraviolet/TiO2/H2O2 process
    Zhang Bo
    Zhong Zhao-ping
    Fu Zong-ming
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2015, 22 (01) : 82 - 87
  • [43] Photocatalytic oxidation of nitric oxide from simulated flue gas by wet scrubbing using ultraviolet/TiO2/H2O2 process
    张波
    仲兆平
    付宗明
    Journal of Central South University, 2015, 22 (01) : 82 - 87
  • [44] Photocatalytic oxidation of nitric oxide from simulated flue gas by wet scrubbing using ultraviolet/TiO2/H2O2 process
    Bo Zhang
    Zhao-ping Zhong
    Zong-ming Fu
    Journal of Central South University, 2015, 22 : 82 - 87
  • [45] Temperature measurement by laser induced fluorescence of nitric oxide in combustion flame
    Yorozu, M
    Okada, Y
    Endo, A
    COMBUSTION DIAGNOSTICS, 1997, 3108 : 80 - 86
  • [46] Measurement of nitric oxide and 8-isoprostane in exhaled breath of children with atopic eczema
    Zinelli, C.
    Caffarelli, C.
    Strid, J.
    Jaffe, A.
    Atherton, D. J.
    CLINICAL AND EXPERIMENTAL DERMATOLOGY, 2009, 34 (05) : 607 - 612
  • [47] Fractional exhaled nitric oxide measurement: Comparison between the Sunvou-CA2122 analyzer and the NIOX VERO analyzer
    Huang, Tingxuan
    Liu, Bicui
    Yang, Dan
    Liu, Chuntao
    JOURNAL OF ASTHMA, 2021, 58 (01) : 52 - 59
  • [48] Fractional Exhaled Nitric Oxide Measurement: Comparison Between Sunvou-CA2122 Analyzer and NIOX VERO Analyzer
    Huang, T.
    Liu, B.
    Liu, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [49] Micro-gas analysis system for measurement of nitric oxide and nitrogen dioxide: Respiratory treatment and environmental mobile monitoring
    Toda, Kei
    Hato, Yuki
    Ohira, Shin-Ichi
    Namihira, Takao
    ANALYTICA CHIMICA ACTA, 2007, 603 (01) : 60 - 66
  • [50] A compact low-noise photodiode detection system for chemiluminescence nitric oxide analyzer
    Li, Hang
    Liu, Wenqing
    Kan, Ruifeng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (04):