Micro Gas Analyzer Measurement of Nitric Oxide in Breath by Direct Wet Scrubbing and Fluorescence Detection

被引:27
|
作者
Toda, Kei [1 ]
Koga, Takahiro [1 ]
Kosuge, Junichi [2 ]
Kashiwagi, Mieko [2 ]
Oguchi, Hiroshi [3 ]
Arimoto, Takemi [3 ]
机构
[1] Kumamoto Univ, Dept Chem, Kumamoto 8608555, Japan
[2] Sekisui Med Co Ltd, Tsukuba Res Inst, Ryugasaki, Ibaraki 3010852, Japan
[3] GASTEC Co, Kanagawa 2521195, Japan
基金
日本科学技术振兴机构;
关键词
NITROGEN-DIOXIDE; ANALYSIS SYSTEM; EXHALED AIR; NITRATE; RELEASE; PHOTOLYSIS; CAVITY; OZONE; ACID; LUNG;
D O I
10.1021/ac901131d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method is proposed to measure NO in breath. Breath NO is a useful diagnostic measure for asthma patients. Due to the low water solubility of NO, existing wet chemical NO measurements are conducted on NO2 after removal of pre-existing NO2 and conversion of NO to NO2. In contrast, this study utilizes direct measurement of NO by wet chemistry. Gaseous NO was collected into an aqueous phase by a honeycomb-patterned microchannel scrubber and reacted with diaminofluorescein-2 (DAF-2). Fluorescence of the product was measured using a miniature detector, comprising a blue light-emitting diode (LED) and a photodiode. The response intensity was found to dramatically increase following addition of NO2 into the absorbing solution or air sample. By optimizing the conditions, the sensitivity obtained was sufficient to measure parts per billion by volume levels of NO continuously. The system was applied to real analysis of NO in breath, and the effect of coexisting compounds was investigated. The proposed system could successfully measure breath NO.
引用
收藏
页码:7031 / 7037
页数:7
相关论文
共 50 条
  • [31] Direct measurement of nitric oxide concentration in isolated vessels and isolated beating hearts by nitric oxide microsensor
    Mochizuki, S
    Goto, M
    Chiba, Y
    Fukuhiro, Y
    Hirano, K
    Ogasawara, Y
    Tsujioka, K
    Kajiya, F
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1744 - 1745
  • [32] Direct Measurement of Nitric Oxide in Seawater Medium by Fluorometric Method
    Liu Chun-Ying
    Zhao Min
    Ren Chun-Yan
    Yang Gui-Peng
    Li Pei-Feng
    Han Yang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (10) : 1463 - 1467
  • [33] Direct measurement of nitric oxide during experimental cardiopulmonary bypass
    Hamanaka, S
    Tanemoto, K
    Inagaki, E
    Yamasawa, T
    Yoshida, K
    Mochizuki, S
    Goto, M
    Miyasaka, T
    Kajiya, F
    Tanaka, N
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2005, 33 (03) : 295 - 300
  • [34] DIRECT MEASUREMENT OF NITRIC-OXIDE IN THE LUNG-TISSUE
    RAO, KVS
    GRUNFELD, S
    PATTON, S
    MALINSKI, T
    PEDIATRIC RESEARCH, 1994, 35 (04) : A350 - A350
  • [35] Direct measurement of intraretinal nitric oxide in early diabetic retinopathy
    Guthrie, Micah James
    Mieler, Jennifer J. Kang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [36] Direct In-Vivo Measurement of Nitric Oxide in the Rat Retina
    Guthrie, Micah
    Osswald, Christian
    Mieler, Jennifer Kang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [37] DIRECT MEASUREMENT OF NITRIC-OXIDE GENERATION IN THE ISCHEMIC HEART
    WANG, PH
    KUPPUSAMY, P
    ZWEIER, JL
    FASEB JOURNAL, 1995, 9 (03): : A326 - A326
  • [38] Direct measurement of nitric oxide release from the rat hippocampus
    Xian, YZ
    Zhang, W
    Xue, J
    Ying, XY
    Jin, LT
    ANALYTICA CHIMICA ACTA, 2000, 415 (1-2) : 127 - 133
  • [39] DIRECT MEASUREMENT OF NITRIC-OXIDE IN HUMAN-BEINGS
    VALLANCE, P
    PATTON, S
    BHAGAT, K
    MACALLISTER, R
    RADOMSKI, M
    MONCADA, S
    MALINSKI, T
    LANCET, 1995, 346 (8968): : 153 - 154
  • [40] Detection of nitric oxide from pig trachea by a fluorescence method
    Lozinsky, EM
    Martina, LV
    Shames, AI
    Uzlaner, N
    Masarwa, A
    Likhtenshtein, GI
    Meyerstein, D
    Martin, VV
    Priel, Z